A dedicated exhaust port (M5) is installed to remove air from the nozzle. The IT series comes with monitor signal output and shock/ vibration resistance., E/P REGULATOR W/GAUGE, INSTRUMENTATION, IT2000/ITV2000 E/P REGULATOR, DA, IT2000 1/4 INCPT VERSION, .88184 lb
A dedicated exhaust port (M5) is installed to remove air from the nozzle. The IT series comes with monitor signal output and shock/ vibration resistance., E/P REGULATOR 1/4 PT, INSTRUMENTATION, IT2000/ITV2000 E/P REGULATOR, DA, IT2000 1/4 INCPT VERSION, 1.60448 lb
A dedicated exhaust port (M5) is installed to remove air from the nozzle. The IT series comes with monitor signal output and shock/ vibration resistance., E/P REGULATOR, INSTRUMENTATION, IT2000/ITV2000 E/P REGULATOR, DA, IT2000 1/4 INCPT VERSION, 1.75796 lb
A dedicated exhaust port (M5) is installed to remove air from the nozzle. The IT series comes with monitor signal output and shock/ vibration resistance., E/P REGULATOR, INSTRUMENTATION, IT4000/ITV3000 E/P REGULATOR, DB, IT4000 1/4 INCNPT VERSION, 1.44760 lb
A dedicated exhaust port (M5) is installed to remove air from the nozzle. The IT series comes with monitor signal output and shock/ vibration resistance., E/P REGULATOR, INSTRUMENTATION, IT4000/ITV3000 E/P REGULATOR, EB, IT4000 3/8 INCNPT VERSION, 1.45200 lb
A dedicated exhaust port (M5) is installed to remove air from the nozzle. The IT series comes with monitor signal output and shock/ vibration resistance., E/P REGULATOR, INSTRUMENTATION, IT4000/ITV3000 E/P REGULATOR, EB, IT4000 3/8 INCNPT VERSION, 2.33384 lb
A dedicated exhaust port (M5) is installed to remove air from the nozzle. The IT series comes with monitor signal output and shock/ vibration resistance., E/P REGULATOR, INSTRUMENTATION, IT4000/ITV3000 E/P REGULATOR, FB, IT4000 1/2 INCNPT VERSION, 1.50920 lb
A dedicated exhaust port (M5) is installed to remove air from the nozzle. The IT series comes with monitor signal output and shock/ vibration resistance., E/P REGULATOR, INSTRUMENTATION, IT4000/ITV3000 E/P REGULATOR, FB, IT4000 1/2 INCNPT VERSION, 1.45200 lb
A dedicated exhaust port (M5) is installed to remove air from the nozzle. The IT series comes with monitor signal output and shock/ vibration resistance., E/P REGULATOR, INSTRUMENTATION, IT4000/ITV3000 E/P REGULATOR, DB, IT4000 1/4 INCNPT VERSION, 1.48720 lb
Model: 51 (Bottom Ported), Connector Type: P (Flat Ribbon Cable, 26 Pins), Connector Entry Direction: 1 (Upward), Wiring Specification: All Double Wiring, Valve Stations: 12 Stations, P,E Port Location: D Side, A,B Port Size: M5, Thread: T (NPTF)
Model: 51 (Bottom Ported), Connector Type: P (Flat Ribbon Cable, 26 Pins), Connector Entry Direction: 1 (Upward), Wiring Specification: All Double Wiring, Valve Stations: 10 Stations, P,E Port Location: D Side, A,B Port Size: M5, Thread: T (NPTF)
Model: 51 (Bottom Ported), Connector Type: P (Flat Ribbon Cable, 26 Pins), Connector Entry Direction: 2 (Lateral), Wiring Specification: All Double Wiring, Valve Stations: 7 Stations, P,E Port Location: D Side, A,B Port Size: M5, Thread: T (NPTF)
Model: 51 (Bottom Ported), Connector Type: P (Flat Ribbon Cable, 26 Pins), Connector Entry Direction: 1 (Upward), Wiring Specification: All Double Wiring, Valve Stations: 6 Stations, P,E Port Location: D Side, A,B Port Size: M5, Thread: T (NPTF)
Model: 51 (Bottom Ported), Connector Type: P (Flat Ribbon Cable, 26 Pins), Connector Entry Direction: 1 (Upward), Wiring Specification: All Double Wiring, Valve Stations: 7 Stations, P,E Port Location: D Side, A,B Port Size: M5, Thread: T (NPTF)
Model: 51 (Bottom Ported), Connector Type: P (Flat Ribbon Cable, 26 Pins), Connector Entry Direction: 1 (Upward), Wiring Specification: All Double Wiring, Valve Stations: 8 Stations, P,E Port Location: D Side, A,B Port Size: M5, Thread: T (NPTF)
Sensor Range: 0 [Positive pressure (0 to 1 MPa)], Accuracy: ±2% F.S., Port Size: IM5 (M5 Female Thread Through Type), Output Specification: P (PNP open collector 1 output), Lead Wire Termination: S (With M12-4 pin connector, 500 mm), Set Value: P (Normal Output), OUT1 Set Value: 000 (0.0 MPa, 0 kPa, 0 kPa), OUT1 Hysteresis: 1 (0.01 MPa, 1 kPa, 1 kPa)
A dedicated exhaust port (M5) is installed to remove air from the nozzle. The IT series comes with monitor signal output and shock/ vibration resistance. REGULATOR, E/P, HIGH PRESSURE. High Press. E/P Regulator. 700.00000 lb. N11.
Sensor Range: 0 [Positive pressure (0 to 1 MPa)], Accuracy: ±2% F.S., Port Size: 01 [R 1/8(w/M5 Female)], Output Specification: P (PNP open collector 1 output), Lead Wire Termination: Basic, Set Value: P (Normal Output), OUT1 Set Value: 004 (0.4 MPa, −40 kPa, 40 kPa), OUT1 Hysteresis: 6 (0.06 MPa, 6 kPa, 6 kPa)
Horizontal 10 10 P.10 Standard motor 6 6 P.18 Vertical 10 10 P.26 Frame-type linear guide LTF 6 6 P.34 Horizontal 10 10 P.42 Non-standard motor 6 6 P.50 Vertical 10 10 P.58 Options P.66 Construction P.67 Mounting P.68 Non-standard Motor Mounting P.69 Deflection Data P.71 Part Number Designations P 1 E F G LTF 6 100 R 2 X10 Motor specification Lead screw lead Series Series 6 Nil
min (ANR)) Flow rate (L/min (ANR)) AEP HEP Construction i e AL800/900 r y q IN OUT t o !