Cushion adjustment (relief adjustment) labor is the same as general purpose cylinder adjustment (cushion needle adjustment). 200 150 Cushioning quality (RHCF40-500, load weight 5kg, supply pressure 0.5MPa, horizontal drive) High power cylinder 500 General purpose cylinder Cushioning capacity [J] 100 1000mm/s 3000mm/s 2000mm/s 500mm/s 400 Stroke [mm] 300 50 200 100 50mm/s 20 25 32 40 50 63
1 digit (Ambient temperature of 25 3C) Repeatability 0.2% F .S. 1 digit Analog output accuracy 2.5% F .S.
B C E E H L1 L1 L2 L2 M Min. port size LQ3E2A-S 1/4" 4 6 17 16 16 34.5 33.5 39.5 38.5 20 3.9 LQ3E3A-S 3/8" 5 9 22.5 19.5 21 47.5 44.5 49.5 46.5 25 6.3 LQ3E4A-S 1/2" 6 10 24.5 22.5 24 52.5 50.5 54.5 52.5 29 9.5 LQ3E5A-S 3/4" 7 14 26.5 24 32 64 61.5 66 63.5 37 15.8 LQ3E6A-S 1" 8 18 30 26 41 78 74 80 76 49 22 LQ3E7A-S 1 1/4" 9 22 35 35 50 92.5 92.5 97.5 97.5 64 28 M H Class 7 929 A LQ3 Series
WA WB View E NN F GB GC GA Mounting nut Mounting nut Relief port M5 x 0.8 Rod end nut MM NN F Piping port 2 x M5 x 0.8 Cover surface D LY LB LH LT LZ LX LT S + Stroke H NA A NB Y X Y X 4 x LC Mounting hole LS + Stroke Z + Stroke WW C B 0 0.3 B 0 0.3 Drawing of view (E) (mm) Z S WW WB WA NB NA NN MM H GB GA F D C B A Y X 91.5 92.5 LS LZ 42 42 25 25 LY LX 33 33 2.3 2.3 LT 14 14 LH 5.5 5.5 LC
Maximum piston speed: 1000 mm/s It can be used at 50 to 1000 mm/s provided that it is within the allowable kinetic energy range.
Maximum piston speed: 500 mm/s It can be used at 50 to 500 mm/s provided that it is within the allowable kinetic energy range.
VQ valves are ideal for applications requiring high speed, frequent operation, stable response time and long service life. Innovative mounting methods allow valves to be changed without entirely disassembling the manifold. Built-in one-touch fittings save piping time and labor. Individual lead wire type, P and R ports on one side for space savings, Maximum 8 stations available as standard
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, MFLD, PLUG-IN, VQ2000, VALVE, VV5Q* MANIFOLD VQ 4/5 PORT, WM, VV5Q* BUILT IN FITTING >1/4, 1.10231 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, MFLD, PLUG-IN, VQ2000, VALVE, VV5Q* MANIFOLD VQ 4/5 PORT, WM, VV5Q* BUILT IN FITTING >1/4, 1.65346 lb
VQ valves are ideal for applications requiring high speed, frequent operation, stable response time and long service life. Innovative mounting methods allow valves to be changed without entirely disassembling the manifold. Built-in one-touch fittings save piping time and labor. Base mounted plug-in type manifold for VQ2*0* valve, Serial interface (SI) type, Maximum 16 stations available
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, MFLD, PLUG-IN, VQ2000, VALVE, VV5Q* MANIFOLD VQ 4/5 PORT, UM, VV5Q* BUILT IN FITTING 2.44797 lb, 2.44797 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, MFLD, PLUG-IN, VQ2000, VALVE, VV5Q* MANIFOLD VQ 4/5 PORT, UM, VV5Q* BUILT IN FITTING 3.68773 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, MFLD, PLUG-IN, VQ2000, VALVE, VV5Q* MANIFOLD VQ 4/5 PORT, UM, VV5Q* BUILT IN FITTING 4.12526 lb, 4.12526 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, MFLD, PLUG-IN, VQ2000, VALVE, VV5Q* MANIFOLD VQ 4/5 PORT, UM, VV5Q* BUILT IN FITTING 1.85188 lb, 1.85188 lb
VQ valves are ideal for applications requiring high speed, frequent operation, stable response time and long service life. Innovative mounting methods allow valves to be changed without entirely disassembling the manifold. Built-in one-touch fittings save piping time and labor. Base mounted, plug-in type manifold for VQ2*0* valve, D-sub connector (25 pin standard, 15 pin option), Top or
VQ valves are ideal for applications requiring high speed, frequent operation, stable response time and long service life. Innovative mounting methods allow valves to be changed without entirely disassembling the manifold. Built-in one-touch fittings save piping time and labor. Base mounted, plug-in type manifold for VQ2*0* valve, D-sub connector (25 pin standard, 15 pin option), Top or
VQ valves are ideal for applications requiring high speed, frequent operation, stable response time and long service life. Innovative mounting methods allow valves to be changed without entirely disassembling the manifold. Built-in one-touch fittings save piping time and labor. Base mounted, plug-in type manifold for VQ2*0* valve, D-sub connector (25 pin standard, 15 pin option), Top or
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, MFLD, PLUG-IN, VQ2000, VALVE, VV5Q* MANIFOLD VQ 4/5 PORT, 1M, VV5Q* OTHER SIZE RATING, 2.25605 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, MFLD, PLUG-IN, VQ2000, VALVE, VV5Q* MANIFOLD VQ 4/5 PORT, 1M, VV5Q* OTHER SIZE RATING, 2.25605 lb
VQ valves are ideal for applications requiring high speed, frequent operation, stable response time and long service life. Innovative mounting methods allow valves to be changed without entirely disassembling the manifold. Built-in one-touch fittings save piping time and labor. Base mounted, plug-in type manifold for VQ2*0* valve, D-sub connector (25 pin standard, 15 pin option), Top or