Valve; Stop Valve: None), Return Port Size: 04 (1/2), Flow Switch Output Specifications: F (Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA; Temp.: None; Temperature Sensor: None), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Flow Switch Unit Specifications: M (Integrated Display: L/min; Accumulated Flow: L; Temp.: °C; Integrated Display IO-Link: L/min; Accumulated Flow: L; Temp.: °C)
Valve; Stop Valve: None), Return Port Size: 03 (3/8), Flow Switch Output Specifications: F (Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA; Temp.: None; Temperature Sensor: None), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Flow Switch Unit Specifications: M (Integrated Display: L/min; Accumulated Flow: L; Temp.: °C; Integrated Display IO-Link: L/min; Accumulated Flow: L; Temp.: °C)
Valve; Stop Valve: None), Return Port Size: 03 (3/8), Flow Switch Output Specifications: A (Out 1: NPN; Out 2: Flow Rate: NPN; Temp.: None; Temperature Sensor: None), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Flow Switch Unit Specifications: M (Integrated Display: L/min; Accumulated Flow: L; Temp.: °C; Integrated Display IO-Link: L/min; Accumulated Flow: L; Temp.: °C)
Valve; Stop Valve: None), Return Port Size: 04 (1/2), Flow Switch Output Specifications: DT (Out 1: NPN; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Flow Switch Unit Specifications: M (Integrated Display: L/min; Accumulated Flow: L; Temp.: °C; Integrated Display IO-Link: L/min; Accumulated Flow: L; Temp
Valve; Stop Valve: None), Return Port Size: 04 (1/2), Flow Switch Output Specifications: DT (Out 1: NPN; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Flow Switch Unit Specifications: M (Integrated Display: L/min; Accumulated Flow: L; Temp.: °C; Integrated Display IO-Link: L/min; Accumulated Flow: L; Temp
Valve; Stop Valve: None), Return Port Size: 04 (1/2), Flow Switch Output Specifications: DT (Out 1: NPN; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Flow Switch Unit Specifications: M (Integrated Display: L/min; Accumulated Flow: L; Temp.: °C; Integrated Display IO-Link: L/min; Accumulated Flow: L; Temp
Valve: None; Stop Valve: None, Supply/Return Port Size: 06 (3/4), Return Unit Flow Switch Output Specifications: C (Out 1: NPN; Out 2: Flow Rate: Analog 1 to 5 V; Temp.: None; Temperature Sensor: None), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Return Unit Flow Switch Unit Specifications: M (Integrated Display: L/min; Accumulated Flow: L; Temp.: °C; Integrated Display IO-Link: L/min;
Valve; Stop Valve: None), Return Port Size: 04 (1/2), Flow Switch Output Specifications: L2T [Out 1: IO-Link/Switch Output (N/P); Out 2: Flow Rate/Temp.: Switch Output (N/P); Temperature Sensor: Yes], Lead Wire: Q (w/M12 -M8 Conversion Lead Wire, 0.1 m), Flow Switch Unit Specifications: M (Integrated Display: L/min; Accumulated Flow: L; Temp.: °C; Integrated Display IO-Link: L/min; Accumulated
Symbol SOL.1 SOL.2 F SW PL LS1,2 M R 4 port solenoid valve 4 port solenoid valve Fuse Snap switch Light Micro switch Timing motor Resistor 135 ID Series Dimensions Bracket (Option) 4 x L Mounting holes Port size Female thread Exhaust regeneration (ID40, 60) Power supply cable [100 VAC specifications] Cord with an attachment plug (Length: 2 m) [200 VAC specifications] Cabtire cord (Length
(60 Hz) 11 VA (50 Hz), 7 VA (60 Hz) Without indicator light: 6 W, With indicator light: 6.3 W ZNR (Varistor), Neon bulb ZNR (Varistor), LED (Neon bulb for 100 V or more) Inrush Holding Apparent power (3) AC Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Power consumption
R/W undetected: NFC reader/writer driver is installed. NFC reader/ writer is not identified or USB is not connected. R/W detection/ R/W no-detection button 5 R/W detected: NFC communication with the wireless unit is available. When the Advanced Card Systems Ltd. ACR1251U/ACR1252U is used. No driver: NFC reader/writer is not identified or USB is not connected.
R/W undetected: NFC reader/writer driver is installed. NFC reader/ writer is not identified or USB is not connected. R/W detection/ R/W no-detection button 5 R/W detected: NFC communication with the wireless unit is available. When the Advanced Card Systems Ltd. ACR1251U/ACR1252U is used. No driver: NFC reader/writer is not identified or USB is not connected.
R/W undetected: NFC reader/writer driver is installed. NFC reader/ writer is not identified or USB is not connected. 5 R/W connection status R/W detected: NFC communication with the wireless unit is available. When the Advanced Card Systems Ltd. ACR1251U/ACR1252U is used. No driver: NFC reader/writer is not identified or USB is not connected.
(Type 20 manifold) 10 23 5 M 1 M3 SYJ3 Body ported Base mounted (4 port) 2 10 SYJ3 33 5 M (Manifold use only) Base mounted (5 port) SYJ3 43 M 2 5 10 Clean series 4 port Port size Coil specifications Manual override Nil Standard With power saving circuit <24, 12 VDC only> Nil: Non-locking push type Nil: Without sub-plate T Power saving circuit is not available in the case of "W" type.
Holder Assy Model Number LQ-GCLQ-GPC w w w . s m c u s a . c o m SMC PNEUMATICS INC. U.S. HEADQUARTERS 3011 N. FRANKLIN ROAD INDIANAPOLIS INDIANA 46226 PHONE: 317-899-4440 FAX: 317-899-3102 TOLL FREE: 1-800-SMC-SMC1 1978-2000 SMC Pneumatics, Inc. All Rights Reserved. JB
Supprressor: Z (w/Light Surge Voltage Suppressor), Manual Override: Non-locking Push Type, Vacuum Pressure Sensor: V (Pressure Switch for Vacuum w/Energy Saving Function, Compound Pressure 1 Output), Output: B (PNP Open Collector), Unit: M (SI Unit Only, kPa), Lead Wire: W (Lead Wire for Switch w/Energy Saving Function; Length: 2 m; Included), Option: B (Adapter Assembly for Bottom Mounting
R/W detected: NFC communication with the wireless unit is available. R/W undetected: NFC reader/writer is not identified or USB is not connected. Installation not performed: NFC reader/writer driver is not installed. R/W detection/ R/W no-detection button 5 Refer to Preparation befor use (2. Preparation befor use (page 7)).
Stations: 03 (3 Stations), Piping: B (U Side: Open; D Side: Open), Thread Type: N (NPT), Supply Unit Components: W (w/Flow Adj. Valve; w/Stop Valve), Return Unit Flow Switch: 7 (Integrated Display), Return Unit Flow Range: 04 (0.5 to 4 L/min), Return Unit Components: W (w/Flow Adj.
Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: BT (Out 1: PNP; Out 2: Flow Rate: PNP; Temp.: PNP; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector), Return Unit Flow Switch Unit Specifications: M (Integrated Display: L/min; Accumulated Flow: L; Temp.: °C; Integrated Display IO-Link: L/min; Accumulated Flow: L;
Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: A (Out 1: NPN; Out 2: Flow Rate: NPN; Temp.: None; Temperature Sensor: None), Lead Wire: N (w/o Lead Wire and M8 Connector), Return Unit Flow Switch Unit Specifications: M (Integrated Display: L/min; Accumulated Flow: L; Temp.: °C; Integrated Display IO-Link: L/min; Accumulated Flow: L