SMC Corporation of America
Elite Part Number Search
Search Results "KM15-04-08-3"

Manifold Mounting: B (DIN Rail Mount), Centralized Supply (IN) Piping Position: 1 (Bottom), Regulator Block Stations: 1 Station, IN/OUT Fitting Type: 08 [IN/ø6 (Straight) - OUT/ø6 (Straight)], Accessories: A (w/Pressure Gauge/L Side)

. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: A (Digital Pressure Switch for Vacuum / 0 to -101 kPa / NPN 2 Outputs), Connector: L [L-type Plug Connector - w/ Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 08 [ø8 One-touch Fitting (Metric)]

. / N.C.), Rated Voltage: 5 (24 VDC), IO-Link compatible vacuum pressure switch: 5 (-100 to 100 kPa, w/ Unit Selection, w/Energy Saving), Connector: L3 (without connector), Vacuum, V Port: 08 (ø8 One-touch Fitting, Metric), Bracket: w/o Option, Individual Release Pressure Supply: w/o Option, Vacuum Break Flow Adjustment: J (Vacuum Break Flow Adjustment Needle Round Lock Nut Type)

Series: SS5Y3 (SY3000 Manifold), Model: 10S (Side-Ported, Serial Interface), SI Unit Specification: VA (CC-Link - 32 Outputs - Connector M12), SI Unit Output Polarity: Positive Common, NPN or w/o SI Unit, Valve Stations: 08 Stations, P, E Port Location: D (D Side), SUP/EXH Block: Internal Pilot, A, B Port Size: C4 (ø4 One-touch Fitting), Mounting: D (DIN Rail Mounting w/o Name Plate, w/o

Valve Stations: 08 (8 Stations), Port Size: 40 (Barb Fitting), Voltage: 5 (24VDC), Coil Specifications: T [w/Power-Saving Circuit (Continuous Duty Type)(+COM)], Operating Pressure Range: H [Standard (0 to 0.7 MPa)], Connector Cable: C3 (Length 1000mm)

Pad Diameter: 50 (Flat+Flat with Ribs+Bellows), Pad Styles: U (Flat Style), Material: N (NBR), Rotation: J (Rotating), Stroke: 30mm, Vacuum Entry: 08 (One-touch Fitting Ø8), Mounting Thread: A14 (M14X1)

Series: SS5Y3 (SY3000 Manifold), Model: 10S (Side-Ported, Serial Interface), SI Unit Specification: DA (EtherCAT - 32 Outputs - Connector M12), SI Unit Output Polarity: N (PNP), Valve Stations: 08 Stations, P, E Port Location: B (Both Sides), SUP/EXH Block: S (Internal Pilot, Built-in Silencer), A, B Port Size: N7 (ø1/4" One-touch Fitting)

This is a legacy product, and replaced byZK2A07K5CLA-08 VACUUM EJECTOR. Vacuum Ejector. 99 lb.

. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: C (Digital Pressure Switch for Vacuum / 0 to -101 kPa / PNP 2 Outputs), Connector: C [Common Wiring (plug-in) - w/o Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 08 [ø8 One-touch Fitting (Metric)], Bracket: w/o Option, Individual Release Pressure Supply: w/o Option, Vacuum Break Flow

. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: H (Digital Pressure Switch for Vacuum / -100 to 100 kPa / PNP 2 Outputs), Connector: L [L-type Plug Connector - w/ Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 08 [ø8 One-touch Fitting (Metric)], Bracket: B [With One Bracket for Mounting a Single Unit (Mounting Screw is Attached)],

The use of 34 pin connectors allows up to 16 stations with double solenoids.Tie rod base EX250 type manifold for SV1000 valves, Serial wiring with input/output unit, IP67 protection, Number of inputs/outputs: 32 each, Maximum 20 stations available as standard, Optional DIN rail mount, 6 port sizes available "SS5V 08 Station Manifold. 4/5 PORT SOLENOID VALVE. N lb. SV.

"SS5V 08 Station Manifold. 4/5 PORT SOLENOID VALVE. N lb. SV.

. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: R (Digital Pressure Switch for Vacuum with Energy Saving Function / 100 to -100 kPa / PNP 1 Output), Connector: W (With Lead Wire for Switch with Energy Saving Function), Vacuum, V Port: 08 [ø8 One-touch Fitting (Metric)], Bracket: B [With One Bracket for Mounting a Single Unit (Mounting Screw is Attached)], Individual Release Pressure

Reduction Silencer Exhaust), Nominal Nozzle Size: 10 (ø1.0), Supply Valve and Release Valve: R (Self-holding Release Valve Linked / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: A (Digital Pressure Switch for Vacuum / 0 to -101 kPa / NPN 2 Outputs), Connector: L [L-type Plug Connector - w/ Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 08

Series: SS5Y3 (SY3000 Manifold), Model: 10S (Side-Ported, Serial Interface), SI Unit Specification: EA (EtherNet/IPâ„¢ - 32 Outputs - Connector M12), SI Unit Output Polarity: N (PNP), Valve Stations: 08 Stations, P, E Port Location: D (D Side), SUP/EXH Block: S (Internal Pilot, Built-in Silencer), A, B Port Size: C4 (ø4 One-touch Fitting), Mounting: D (DIN Rail Mounting w/o Name Plate, w/

Series: SS5Y3 (SY3000 Manifold), Model: 10S (Side-Ported, Serial Interface), SI Unit Specification: EA (EtherNet/IPâ„¢ - 32 Outputs - Connector M12), SI Unit Output Polarity: N (PNP), Valve Stations: 08 Stations, P, E Port Location: D (D Side), SUP/EXH Block: R (External Pilot), A, B Port Size: C4 (ø4 One-touch Fitting), Mounting: D (DIN Rail Mounting w/o Name Plate, w/o Station Number)

. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: R (Digital Pressure Switch for Vacuum with Energy Saving Function / 100 to -100 kPa / PNP 1 Output), Connector: W (With Lead Wire for Switch with Energy Saving Function), Vacuum, V Port: 08 [ø8 One-touch Fitting (Metric)], Bracket: w/o Option, Individual Release Pressure Supply: w/o Option, Vacuum Break Flow Adjustment: E (Vacuum Break

Voltage: 5 (24VDC), Electrical Entry: L (L Plug Connector), Lead Wire: Lead Wire, Orifice Size: 08 (0.8mm), Port Size: M5 (w/Sub-Plate M5x0.8), Body/Seal Material: A (Body C36, Seal FKM)