Equipment Uo (or Voc) lo (or Isc) Po Co (or Ca) Lo (La) Ui li Pi Ci + Ccable Li + Lcable If the cable capacitance and inductance are unknown, use the following values: Ccable = 60 pF/ft., Lcable = 0.2 H/ft.
Pressure Regulator for General Applications Series BP1000 Operating pressure: 0.5 to 300 psig (0.0034 to 2.1 MPa) Body material: Stainless steel and Brass available Hastelloy internals available for corrosion resistance How to Order Port Number q w e r BP10 01 4PL 4 4 S 0 0 Operating pressure Bonnet option Code pressure 0.5 to 10 psig (0.0034 to 0.07 MPa) 1 to 30 psig (0.007 to 0.2 MPa) 2 to 60
Wiring of power source for driving counter For power source for driving counter, use the one with 90 to 264 VAC, 50/60 Hz or 21.6 to 26.4 VDC, 0.4 A or more. 3. Output circuit There are two outputs, the NPN open collector and the PNP open collector. The maximum rating is 30 VDC, 50 mA. Operating the controller by exceeding this voltage and amperage could damage the electric circuit.
CE2 IN 84.8 59 42 25 CQSY16-PS 12 6 OUT 113 79 57 34 CQSY20-PS ML2B IN 151 106 75 45 CQSY25-PS 16 8 OUT 201 141 101 60 When only grease for maintenance is necessary, please order by the following part numbers.
The angle is 60 when any of the following auto switches are used: D-90/90A/97/93A The angle is 69 when any of the following auto switches are used: D-S99(V)/T99(V)/S9P(V) 3.
Note 3) As a guide, the load mass should be approximately 60% of the thrust load factor. 32 40 Note 1) Exceeding the allowable pressure will lead to the breaking of the magnetic coupling and cause the piston slider and external slider becoming separated.
Add 10 g for conduit, 30 g for DIN terminal, and 60 g for conduit terminal type respectively. Note 3) Refer to Glossary of Terms on page 226 for details on the maximum operating pressure differential and the maximum system pressure.
Note 3) The symbol F in the dimensions indicates the position where the clamping force is generated defined by the product specifications. 82 WRF100 Dimensions WRF-S/S-type clamp arms (Without cover) WRF100-S200/S240 4 x M8 x 1.25 depth 12 108 60 2 x M12 x 1.75 through 25 25 80 0.015 0 2 x 8H7 ( ) 60 0.05 depth 12 (2 x 4 x M5 x 0.8 through) ( ) C B For limit switch mounting A 60 60 36 0.5
Install this product after discharging the drainage that has already accumulated in Mounting Example Compressor Aftercooler Air tank Main line filter Air dryer How to Order ADM200 Port size OUT IN Symbol 04 03 3 8 3 8 Construction/Dimensions 1 2 3 8 Voltage 100 VAC Hz 1 50 60 200 VAC Hz 50 60 240 VAC Hz 50 60 110 VAC Hz 50 60 220 VAC Hz 50 60 24 VDC 12 VDC 2 3 4 5 6 7 Set screw Operating
The intersection E is the dew point under pressure 0.7 MPa with the ambient temperature of 30C and the relative humidity of 60%. Value for E is at 62C. 5. Trace the intersection E upward, and C leftward to obtain the intersection D. 6. The intersection C is the amount of water included in the compressed air 1 m3 at 0.7 MPa with the pressure dew point of 62C.
CE2 IN 84.8 59 42 25 CQSY16-PS 12 6 OUT 113 79 57 34 CQSY20-PS ML2B IN 151 106 75 45 CQSY25-PS 16 8 OUT 201 141 101 60 When only grease for maintenance is necessary, please order by the following part numbers.
YB-03 32, 40 80 9 6.5 10 18 50 d2 d1 YB-05 50, 63 120 11 6.5 12 22 60 L UT C UA (mm) Part No.
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, LUBRICATOR, AIRLINE EQUIPMENT, AL MASS PRO, HA, AL MASS PRO 1 MODULAR (PT), 3.09978 lb, ModelPort sizeFluidProof pressureMaximum operating pressureNote)Minimum dripping flow rate ( /min (ANR))Oil capacity (cm3)Recommended lubricantAmbient and fluid temperatureBowl materialBowl guardWeight (kg)AL503
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, LUBRICATOR, AIRLINE EQUIPMENT, AL MASS PRO, HA, AL MASS PRO 1 MODULAR (PT), 3.66298 lb, ModelPort sizeFluidProof pressureMaximum operating pressureNote)Minimum dripping flow rate ( /min (ANR))Oil capacity (cm3)Recommended lubricantAmbient and fluid temperatureBowl materialBowl guardWeight (kg)AL601Air1.5
Cost effective and clean looking, series AR regulators offer various pressure range settings to accommodate most applications. The locking adjustment knob prevents accidental setting changes. The modular design of the AR series connects with other SMC air preparation equipment.Modular type regulator, Optional embedded pressure gauge , Available with built-in backflow mechanism , Knob is
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, "ACTUATOR, ACTUATOR, ELECTRIC ACTUATOR, HC, 20MM LE ELECTRIC ACTUATOR
Applications that call for precise movement ranging from 10-150mm * typically require a cylinder and a precision guide. The MXS accomplishes this by integrating a cross roller bearing with a guide and two small air cylinders for compact force generation. The MXS is available in six sizes each with set stroke lengths and is standard with auto switch capability. Stroke adjustments are available
The MXQ precision slide is ideal for applications requiring closely held parallelism and perpendicular specifications. The table and bearing guide are integrated into one precisely machined part made of hardened stainless steel. This minimizes tolerance stack-up associated with multiple part assemblies, and affords height tolerances of +/-0.05mm. The bearing is a recirculating linear guide
Applications that call for precise movement ranging from 10-150mm * typically require a cylinder and a precision guide. The MXS accomplishes this by integrating a cross roller bearing with a guide and two small air cylinders for compact force generation. The MXS is available in six sizes each with set stroke lengths and is standard with auto switch capability. Stroke adjustments are available
Setting range: 0.1/0.2/0.5/1/2/5/10/30/60 s (Initial value 1 s) The analogue input update time is set for every wireless slave unit. Analogue input update time Define the address assignment direction of the EX600 I/O units connected to the wireless master unit. The address assignment direction is changed by mode 1/mode 2. Be careful about the I/O map.