Indoor Outdoor Temperature control accuracy 0.01 to 0.03C Users equipment 1 Temperature sensor Users equipment 2 Heat source Users equipment 3 Thermo-chiller for facility water circuit HRSH Series HRS100/150 Series Water-cooled thermo-con HECR-W If the external temperature sensor is installed directly on the heat source, the learning control function may not work properly due to a large heat

It is particularly impossible to use liquid including metallic powder such as iron powder. pH (at 25C) 6.5 to 8.2 Electric conductivity (25C) [S/cm] 100*1 to 800*1 Chloride ion (Cl) [mg/L] 200 or less Sulfuric acid ion (SO42) [mg/L] 200 or less Standard item Acid consumption amount (at pH4.8) [mg/L] 100 or less Total hardness [mg/L] 200 or less Calcium hardness (CaCO3) [mg/L] 150

Fittings & Tubing Air Cylinders Rotary Actuators ARP20(K) 1021 ARP20(K) 1021 Rc1/4 0.50 0.25 0.45 0.40 Outlet pressure (MPa) Outlet pressure (MPa) 0.35 Set point 0.30 0.20 0.25 0.20 0.15 0.10 0.05 0.15 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.00 0 50 100 150 200 250 300 Flow rate (L/min (ANR)) Inlet pressure (MPa) 1021 1021 ARP30(K) ARP30(K) Rc3/8 0.50 0.25 0.45 Air Preparation Equipment 0.40

0.1 B L H G Effective thread depth J 2-Port size D I NB NB T N K W N S + Stroke F F NA R ZZ + Stroke 43 35 29 22 20.5 27.8 D Model Port size K NN B L MM x J N NA H 16 15 10 I 46 36 30 NB 19 17 17 T S 11 9 8 G ZZ 10 8 8 R 60 50 50 W 16 16 13 F 40 40 30 X 12-REA40 12-REA32 12-REA25 Rc, NPT, G 1/8 Rc, NPT, G 1/8 Rc, NPT, G 1/4 70 60 46 M26 x 1.5 M26 x 1.5 M32 x 2.0 21 17 15 50 40 34 19 15 13 150

ON: 5 or less, OFF: 4 or less Response time (DC) ms Note 1) 20 Max. operating frequency (Hz) Manual override Non-locking push type, push-turn locking slotted type Not required Lubrication Unrestricted Mounting position 150/30 Impact / vibration resistance (m/s2) Note 2) Dust tight Enclosure Note 1) Based on dynamic performance test, JIS B 8374-1981 (Standard type :Coil temperature 20C, at

operated poppet valve Air/Inert gas 0.7 MPa 0 MPa/101.2 kPa ON: 4 ms 1, OFF: 2 ms 1 10 to 50C Note 2) Valve specifications Electrical specification Minimum operating pressure / Vacuum Response time Note 1) L plug connector Base mounted L plug connector Body ported Ambient and fluid temperature Lubrication Manual override Impact / Vibration resistance Note 3) Not required Non-locking push type 150

Representative values) Working Principle: AL10 Type AL10 M5 AL40-06 Rc 3/4 Needle fully opened 0.1 Open 1.5 turn Open 1.0 turn Open 2.0 turn Open 0.5 turn 0.1 P1 = 0.5 MPa P1 = 0.3 MPa P1 = 0.7 MPa Pressure drop (MPa) Pressure drop (MPa) 0.08 0.08 Needle Section AA P1 = 0.1 MPa 0.06 0.06 0.04 0.04 0.02 0.02 Conditions: P1 = 0.5 MPa Needle: One side fully opened 0 0 2000 4000 6000 8000 0 0 50 100 150

10, ALDU900-12 to 20 Float switch mounting position Mounting thread M12 R 3.2 S 40 Q IN P M N M L A B C E E F G K J (Bracket mounting dimensions) H D S Bracket (Option) Panel (Option) 6 x 17 A B C D E F G H J K L M N P Q R S Model Port size ALDU600-06 ALDU600-10 ALDU900-12 ALDU900-14 ALDU900-20 289 291.2 453 453 476 24.5 13.6 51 45.5 14.5 69.5 78.2 89 94.5 102.5 4 3 55.5 344 487 145 90 150

AMV15 SP ZCUK 0.015 Inlet pressure (MPa) AMJ AFJ 0.01 AMV AMV AMV15 AMV160 AMV75 AMV37 AMV6 AMV3 ZH -X185 0.005 Related Products 0 100 200 500 1,000 2,000 5,000 10,000 20,000 Flow rate (L/min [ANR]) Dimensions AMV3, 6, 15, 37 AMV 75, 160 B Exhaust Exhaust A A B Port size IN IN C E 8 x d Flange part Model Port size A 231 305 410 710 562 860 B 123 153 210 210 500 500 C 80.7 105.3 d 19 19 E 150

Lockable by installing the AP PL210 to the actuation port of air operated valve (only available for N.C. with actuation port connection NPT 1/8 inch) Prevent accidental valve opening by manually shutting off actuation pressure Lockable only in the closed position Accept standard pad lock with 1/4 inch shackle Actuation port connection:10-32 UNF thread Actuation port pressure rating: Maximum 150

Lockable by installing the AP PL210 to the actuation port of air operated valve (only available for N.C. with actuation port connection NPT 1/8 inch) Prevent accidental valve opening by manually shutting off actuation pressure Lockable only in the closed position Accept standard pad lock with 1/4 inch shackle Actuation port connection:10-32 UNF thread Actuation port pressure rating: Maximum 150

(Individual IN) IN (Common IN) SRP SRF Symbol Model Dimensions ITV C 34 43 D 21 28 E 18 27 F 56 70 G 16 20 H 9 11.5 J 18 24 K 19 28 M 52 66 P 9 11.5 Q 11.5 16.5 R 4.8 4.8 A 4.5 4.5 B 25 34.5 ARM1000 ARM2000 IC ITVH Dimensions by the Number of Stations Manifold stations (n) ITVX Model Symbol 1 36 27 48 39 2 55 46 76 67 3 74 65 104 95 4 93 84 132 123 5 112 103 160 151 6 131 122 188 179 7 150

MPa Flow rate 20 L/min (ANR) Condition: Inlet pressure 0.7 MPa Flow Characteristics (Representative values) Pressure Characteristics (Representative values) ARP20(K) ARP20(K) Rc 1/4 0.50 0.25 0.45 ARJ 0.40 AR425 to 935 Outlet pressure (MPa) Outlet pressure (MPa) 0.35 Set point 0.30 ARX 0.20 0.25 AMR 0.20 ARM 0.15 0.10 ARP ARP 0.05 IR 0.15 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.00 0 50 100 150

Flow rate 20 L/min (ANR) Condition: Inlet pressure 0.7 MPa Flow Rate Characteristics (Representative values) Pressure Characteristics (Representative values) ARP20(K) ARP20(K) Rc 1/4 0.50 0.25 0.45 ARJ 0.40 AR425 to 935 Outlet pressure (MPa) Outlet pressure (MPa) 0.35 Set point 0.30 ARX 0.20 0.25 AMR 0.20 ARM 0.15 0.10 ARP ARP 0.05 IR-A 0.15 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.00 0 50 100 150

Inlet pressure 0.5 MPa Outlet pressure 0.2 MPa Flow rate 20 l/min (ANR) Condition: Inlet pressure 0.7 MPa Flow Characteristics (Representative values) Pressure Characteristics (Representative values) ARP20(K) ARP20(K) Rc1/4 0.50 0.25 0.45 0.40 Outlet pressure (MPa) Outlet pressure (MPa) 0.35 Set point 0.30 0.20 0.25 0.20 0.15 0.10 0.05 0.15 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.00 0 50 100 150

A digital pressure gauge is recommended for such situation or as deemed necessary. 451 AR10-A to AR40-A Series Flow Rate Characteristics (Representative values) Condition: Inlet pressure 0.7 MPa AR10-A M5 AR20-A Rc1/4 0.6 0.6 0.5 0.5 Outlet pressure (MPa) Outlet pressure (MPa) 0.4 0.4 0.3 0.3 0.2 0.2 0.1 0.1 0 0 0 25 50 75 100 125 150 0 200 400 600 800 Flow rate L/min (ANR) Flow rate L/min

AR20K-B to AR60K-B Series Flow Rate Characteristics (Representative values) Condition: Inlet pressure of 0.7 MPa AR10-A M5 AR20(K)-B Rc1/4 AR25(K)-B Rc3/8 AC AF+AR+AL AW+AL AF+AR AF+AFM+AR AW+AFM AF Attachment AFM / AFD AR AL AW 0.6 0.6 0.6 0.5 0.5 0.5 Outlet pressure [MPa] Outlet pressure [MPa] Outlet pressure [MPa] 0.4 0.4 0.4 0.3 0.3 0.3 0.2 0.2 0.2 0.1 0.1 0.1 0 0 00 25 50 75 100 125 150

L3 (1) Model Port size Max. 1 4 1 2 120 150 AS800 AS900 74 93 204 262 192 250 80 94 1 1 , 2 Note 1) L3: Reference dimensions Note 1) L3: Reference dimensions 531 Speed Controller: Standard Type In-line Push Locking Type Series AS RoHS Model/Specifications Lock speed setting, with the touch of a button It can be locked only by pushing the handle after adjustment.

Series: NCDA1K (Non-rotating w/ Magnet), Mounting: C (MP4, Single Detachable Rear Clevis), Bore Size: 150 (1 1/2"), Stroke: 0300 (3")

The multi-stage ZL series is a high-efficiency vacuum generator, which operates at 150% efficiency (compared to about 40% for other units). For each scfm of compressed air it consumes, the ZL generates an incredible 1.587 scfm of suction flow. The ZL is available with a built-in vacuum switch with digital readout for design flexibility.