When making drain exhaust piping, use piping with bore size 8 or larger than 8. Length should be shorter than 5 m. Do NOT pipe upwards. AU200/300 Effective thread depth 6.5 4-M5 x 0.8 AU200, 300 Float type auto-drain Port size H G F E D C B A Model Port size 1 4 / 3 8 AU200 / 50 70 61 30 40.5 31.5 164 165 AU300 50 70 61 30 40.5 31.5 188.5 165 14-3-12
M Element Replacement Procedure Body Model A B C D E F G H I J K L M N Size ZFB100-04 ZFB100-06 ZFB200-06 ZFB200-08 ZFB300-08 ZFB300-10 12.8 4 6 53 54 8.5 14.4 15.5 50 15 17.5 24 12.5 26 22.5 48 Metric size Inch size 15.2 6 8 9.5 16.6 17.5 61 16 19.5 27 13.5 28 65 24.5 52 Collar part arrow 57 8 10 69.5 70 18.5 11 18 21.5 65 17 21 29.5 14.5 30 27 Transparent cover 3 16 1 4 " 1 4 " 3 8 " 1
.: 15 to 145 psi [0.1 to 1.0 MPa] L Port size 1/4, 3/8, 1/2 Drain port size 3/8 Bowl material Polycarbonate Bowl guard material Polycarbonate Weight 0.46 kg Appearance color White 1 Discharged flow rate of the air compressor should be 14 scfm [400 L/min (ANR)] or more. How to Order AD402 04 A D Semi-standard symbol: When plural options are required, indicate them in alphanumeric order.
Rod seal ( Fig.8 ) Pay attention to the mounting direction of the seal. Apply grease to the scraper and the inner circumference of the rod seal as shown in Fig. 8. 2. Piston seal ( Fig. 9 ) Mount with care not to twist the piston seal.
When making drain exhaust piping, use piping with bore size 8 or larger than 8. Length should be shorter than 5 m. Do NOT pipe upwards. AU200/300 Effective thread depth 6.5 4-M5 x 0.8 AU200, 300 Float type auto-drain Port size H G F E D C B A Model Port size 1 4 / 3 8 AU200 / 50 70 61 30 40.5 31.5 164 165 AU300 50 70 61 30 40.5 31.5 188.5 165 14-3-12
Solenoid on side A 0 2 4 6 8 16 28 30 Side D After maintenance is complete, perform appropriate functional inspections. Stop operation if the equipment does not function properly. Safety cannot be assured in the case of unexpected malfunction.
Individual grounding should be provided close to the product with a short cable. 0 2 4 6 8 16 28 30 Solenoid on side A Output No. Valve manifold Accessories Side D NOTE (SI unit side) Replacement of the SI unit Remove the M3 hexagon screws from the SI unit and release the SI unit from the valve manifold. Replace the SI unit.
Nil S MHW -X Tool stand MA210 Y59A S1 MRHQ MA Tool stand DAuto switch type Lead wire length Without auto switch Nil Nil L Grommet With 0.5 m lead wire With 3 m lead wire D-Y59A (3-wire) Y59A Solid state auto switch Lead wire: Axial direction entry D-Y59B (2-wire) Y59B 741
Connector type Connector type SMC Corporation 1-16-4 Shimbashi, Minato-ku, Tokyo 105-8659, JAPAN Tel: 03-3502-2740 Fax: 03-3508-2480 URL http://www.smcworld.com 2001 SMC CORPORATION All Rights Reserved 1st printing December, 2001 D-Export dept. P-100(D) Printed in Japan. This pamphlet is printed on recycled paper with concern for the global environment.
Passage: FG (2-Position), Solenoid: S (Single), Voltage: 3 (24V DC), Option: ZV (Individual Pilot Exhaust, Indicator Light w/Surge Voltage Suppressor), Seal: Metal Seal, Subplate: A02 (Side Ported 1/4), Thread: T (NPTF)
Passage: FG (2-Position), Solenoid: S (Single), Voltage: 3 (24V DC), Option: NV (Indicator Light, Individual Pilot Exhaust), Seal: R (Rubber Seal), Subplate: A03 (Side Ported 3/8), Thread: F (G), Connector: SC (Pre-wired Connector)
Passage: FG (2-Position), Solenoid: S (Single), Voltage: 5 (110 VAC, 50/60Hz), Option: Z (Indicator Light w/Surge Voltage Suppressor), Seal: Metal Seal, Subplate: w/o Subplate, Thread: Rc, Connector: SC (Pre-wired Connector)
Passage: FG (2-Position), Solenoid: S (Single), Voltage: 5 (110 VAC, 50/60Hz), Option: N (Indicator Light), Seal: Metal Seal, Subplate: w/o Subplate, Thread: Rc, Connector: SC (Pre-wired Connector)
Passage: FG (2-Position), Solenoid: S (Single), Voltage: 3 (24V DC), Option: N (Indicator Light), Seal: R (Rubber Seal), Subplate: A02 (Side Ported 1/4), Thread: T (NPTF), Connector: O (DIN Terminal Block w/o Connector)
Passage: 2-Position, Reverse Pressure, Solenoid: Single, Voltage: 24V DC, Option: Indicator Light w/Surge Voltage Suppressor, Seal: -, Subplate: -, Thread: -, Connector: -
Passage: 2-Position, Solenoid: Single, Voltage: 100V AC, Option: Indicator Light w/Surge Voltage Suppressor, Seal: Rubber Seal, Subplate: Side Ported 1/4, Thread: NPTF, Connector: -
Passage: 2-Position, Reverse Pressure, Solenoid: Single, Voltage: 24V DC, Option: -, Seal: -, Subplate: -, Thread: -, Connector: -
Passage: 2-Position, Solenoid: Single, Voltage: 200V AC, Option: Indicator Light, Seal: Metal Seal, Subplate: w/o Subplate, Thread: Rc, Connector: Pre-wired Connector
Passage: 2-Position, Solenoid: Single, Voltage: 200V AC, Option: Indicator Light w/Surge Voltage Suppressor, Seal: -, Subplate: -, Thread: -, Connector: -
Passage: 2-Position, Solenoid: Single, Voltage: 100V AC, Option: Indicator Light w/Surge Voltage Suppressor, Seal: Rubber Seal, Subplate: Side Ported 3/8, Thread: NPTF, Connector: -