Magnet: Built-in Magnet, Mounting: Rod Flange, Tube Material: Aluminum Tube, Bore Size: 63mm, Thread: Rc, Stroke: 100mm, Bellows/Cushion: Cushion Both Sides, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 0.5m Cord Length, M8-3 Pin Connector, Number: 2 pcs. (Or None in the Case of No Switch), Made to Order: w/Heavey Duty Scraper
Series: Standard w/ Magnet, Mounting: MP2, Detachable Rear Clevis, Bore Size: 4", Stroke: 2", Air Cushion / Rod Boot: Both Ends (Air Cushion), Thread: Full Male, Threaded, Adjustment Range: Not Applicable, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 0.5m Cord Length, M8-3 Pin Connector, Number: 2 pcs. (Or None in the Case of No Switch)
SMC has redesigned the NCQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions.? Auto switch mounting grooves have replaced the NCQ2s mounting rails, preventing projection of auto switches and improving?ease and safety of work.Compact, double acting, single rod, large bore , Bore size (mm): 125,?
SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Single acting, single rod, compact cylinder , Bore sizes *: 12, 16, 20, 25
SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, double rod, compact cylinder, Bore sizes *: 12, 16, 20, 25,
SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing p, CYL, COMPACT *LQA, ACTUATOR, CQ2 COMPACT CYLINDER, LE, 32MM CQ2 DBL-ACT AUTO-SW, .83775 lb
Magnet: D (Built-in), Mounting: B [Through Hole (Standard)], Type: Standard, Bore Size: 32mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 30mm, Body Option: Standard (Rod End Female Thread, Without thread on 4mm bore), Auto Switch Groove: Z (Auto Switch Mounting Grooves), Mounting Bolt: None, Rod End Bracket: D (Simple Joint A Type + Joint)
Magnet: D (Built-in Magnet), Mounting: B (Through Hole [Standard]), Bore Size: 32mm, Port Thread Type: Rc; M Thread: 12 to 25, Stroke: 10mm, Body Option: Rod End Female Thread, Auto Switch Groove: Z (12 to 25, 2 surfaces; 32 to 40 4 surfaces), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m or None in the Case of No Switch, Number: 2 pcs. or None in the Case of No Switch
Magnet: D (Built-in Magnet), Mounting: B (Through Hole [Standard]), Bore Size: 32mm, Port Thread Type: Rc; M Thread: 12 to 25, Stroke: 20mm, Body Option: M (Rod End Male Thread), Auto Switch Groove: Z (12 to 25, 2 surfaces; 32 to 40 4 surfaces), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m or None in the Case of No Switch, Number: 2 pcs. or None in the Case of No Switch
Magnet: D (Built-in Magnet), Mounting: B (Through Hole [Standard]), Bore Size: 32mm, Port Thread Type: Rc; M Thread: 12 to 25, Stroke: 100mm, Body Option: M (Rod End Male Thread), Auto Switch Groove: Z (12 to 25, 2 surfaces; 32 to 40 4 surfaces), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m or None in the Case of No Switch, Number: 2 pcs. or None in the Case of No Switch
Magnet: D (Built-in Magnet), Mounting: B (Through Hole [Standard]), Bore Size: 32mm, Port Thread Type: Rc; M Thread: 12 to 25, Stroke: 10mm, Body Option: M (Rod End Male Thread), Auto Switch Groove: Z (12 to 25, 2 surfaces; 32 to 40 4 surfaces), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m or None in the Case of No Switch, Number: 2 pcs. or None in the Case of No Switch
Magnet: D (Built-in Magnet), Mounting: B (Through Hole [Standard]), Bore Size: 32mm, Port Thread Type: Rc; M Thread: 12 to 25, Stroke: 20mm, Body Option: Rod End Female Thread, Auto Switch Groove: Z (12 to 25, 2 surfaces; 32 to 40 4 surfaces), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m or None in the Case of No Switch, Number: 2 pcs. or None in the Case of No Switch
Magnet: D (Built-in Magnet), Mounting: B (Through Hole [Standard]), Bore Size: 32mm, Port Thread Type: Rc; M Thread: 12 to 25, Stroke: 35mm, Body Option: M (Rod End Male Thread), Auto Switch Groove: Z (12 to 25, 2 surfaces; 32 to 40 4 surfaces), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m or None in the Case of No Switch, Number: 2 pcs. or None in the Case of No Switch
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com