Function: 1 (2 Position Single), Piping: 2 (Body Ported), Exhaust: 0 (Individual), Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 6 (12VDC), Lead Wire: H (Grommet Lead Wire 600mm), Light/Surge Suppressor: Without light/surge voltage suppressor, Manual Override: Non-locking Push Type, Port Size: 02 (1/4), Thread: N (NPT)
Body Size: 3 (3/8), Type: 2 (Elbow), Control Type: 0 (Meter-out), Model: 1FSG, Thread: N (NPT), Port Size: 02 (1/4), Width Across Flats: 9 mm (or None: Sizes 2/3/4), Applicable Tubing: 11 (ø3/8"), Seal: S (with Sealant)
Body Class: 2 (Class 2, Orifice ø4), Valve Type: 0 (Normally Closed), Port Size: 02 (1/4), Thread: N (NPT), Material: C (Body: PFA, Endplate: PPS, Diaphragm: PTFE)
Body Size: 2, Set Pressure: 2 (1.5 to 116 psi [0.01 to 0.8 MPa]), Exhaust Direction: 0 (Bottom Exhaust), Thread: N (NPT), Port Size: 02 (1/4), Option: BEC (w/Bracket + NPN Open Collector, 1 Output + Analog Voltage Output), Semi-standard: ZA (Digital Pressure Switch: With Unit Conversion Function)
Function: 2 (2 Position Double), Body Option: 10 (Base Mounted Non Plug-in), Pilot: R (External Pilot), Voltage: 5 (24VDC), Lead Wire: D (DIN Terminal w/Connector), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: B (Locking Slotted Style), Port Size: 02 (Base Mounted w/Sub-plate 1/4 Side Piping), Thread: N (NPT)
Function: 2 (2 Position Double), Body Option: 10 (Base Mounted Non Plug-in), Pilot: R (External Pilot), Voltage: 4 (220VAC 50/60HZ), Lead Wire: D (DIN Terminal w/Connector), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style (Flush), Port Size: 02 (Base Mounted w/Sub-plate 1/4 Side Piping)
AS: AS, Body Size: 2 (1/8, 1/4 Basis), Style: 2 (Elbow), Control Method: 1 (Meter-in), Thread: N (NPT), Port Size: 02 (1/4), Applicable Tube OD: 05 (3/16")
Body Size: 20, Thread: N (NPT), Port: 02 (1/4), Option: C [Float Type Auto Drain (N.C.)], Attachment: Standard, Semi-Standard 1: 23 (2 + 3), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, and Pressure Gauge: psi, °F)
Stations: 11 Stations (Note: 2 Stations are Required for Terminal Box Mounting), Port Size: 02 (Rc1/4), Thread: Rc (PT), Kit Name: T (Terminal Box), Box Mounting Position: 0 (U Side Mounting), Control Unit: None, Release Valve Rated Voltage: w/o Air Release Valve, Option 1: CD (Exhaust Cleaner for D Side Mounting), Option 2: W (IP65 Protection Compatible)
Stations: 3 Stations (Note: 2 Stations are Required for Serial Unit Mounting), Port Size: 02 (Rc1/4), Thread: N (NPT), Kit Name: T (Terminal Box), Box Mounting Position: 0 (U Side Mounting), Control Unit: None, Release Valve Rated Voltage: w/o Air Release Valve, Option 1: None, Option 2: W (IP65 Protection Compatible)
Special Application: 10-AW (Clean Series), Body Size: 20, Reverse Flow: No, Thread: N (NPT), Port Size: 02 [1/4 (Size 20, 30, 40)], Accessory (Not Attached): BG (B+G), Option 1: 2 (Metal Bowl), Option 2: JZ (Drain Guide+Name & Caution Plates for Bowl & Gauge in Imperail Units)
Body Size: 20, Thread: N (NPT), Port Size: 02 (1/4), Option: Standard, Semi-Standard 1: 2J (2 + J), Semi-Standard 2: RZ (R + Z)
Body Size: 20, Thread: N (NPT), Port Size: 02 (1/4), Option: C (N.C. Float Type Auto Drain), Attachment: V (3-Port Valve for Residual Pressure Release; Mounting: AF+AR+V), Semi-Standard 1: 2 (Metal Bowl), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F)
Body Size: 30, Thread: N (NPT), Port Size: 02 (1/4), Option: BD (B + D), Semi-Standard 1: 2 (Metal Bowl), Semi-Standard 2: Z (NPT Porting requires Z, Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F)
Body Size: 20, Thread: Rc: Size 20, 25, 30, 40; M5: Size 10, Port Size: 02 (1/4), Option: H (Set Nut for Panel Mount), Semi-Standard 1: 2 (Metal Bowl), Semi-Standard 2: Standard
Type of Actuation: 2 (2 Position Double), Manifold Type: 20 (Body Ported), Pilot: Internal Pilot, Specifications: Standard, Voltage: 5 (24VDC), Electrical Entry: L (L Plug Connector w/Lead Wire 0.3m), Lead Wire Length: None, Surge Suppressor: U (Surge Suppressor w/Light Non-polar), Manual Override: Non-locking Push Style, Port Size: 02 (Body Ported 1/4, Base Mounted Sub-plate 1/4)
Body Size: 30, Thread: N (NPT), Port Size: 02 (1/4), Option: w/o Bracket; w/o Auto Drain, Semi-Standard 1: 2J (2 + J), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F)
Type of Actuation: 2 (2 Position Double), Manifold Type: 20 (Body Ported), Pilot: Internal Pilot, Specifications: Standard, Voltage: 5 (24VDC), Electrical Entry: D (DIN Terminal w/Connector), Lead Wire Length: None, Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style, Port Size: 02 (Body Ported 1/4, Base Mounted Sub-plate 1/4), Thread: T (NPTF)
Body Size: 20, Thread: N (NPT), Port Size: 02 (1/4), Option: G (for Sizes 20, 25, 30, 40 Round Type Pressure Gauge w/Limit Indicator; for Size10: Round Type Pressure Gauge w/o Limit Indicator), Attachment: S (Pressure Switch), Semi-Standard 1: 2 (Metal Bowl), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F)
Body Size: 20, Thread: N (NPT), Port Size: 02 (1/4), Option: C (N.C., Float Type Auto Drain), Semi-Standard 1: 2 (Metal Bowl), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F)