3-wire (NPN) 2-wire Relay, PLC IC circuit 5 V, 12 V 3-wire (PNP) 12 V 2-wire Relay, PLC 24 V Grommet 3-wire (NPN) 3-wire (PNP) IC circuit 5 V, 12 V Diagnostic indication (2-color indication) 2-wire 12 V Lead wire length symbols: 0.5 m Nil (Example) A93 3 m L (Example) A93L 5 m Z (Example) F9NWZ Solid state switches marked with are produced upon receipt of order.

circuit diagram ZSE5 ISE5 6 9 8 7 10 7 ZSE6 ISE6 OUT1 8 OUT1 OUT2 12 to 24 V DC AUTO SHIFT GND (COM) LED (Green) + 12 to 24V DC OUT2 9 ZSE3 ISE3 LED (Red) 6 GS Input circuit diagram (Autoshift, channel selection) PS 7 Sensor connection 300 ISA + 12 to 24V DC 5 CH.SELECT 1.8k Voltage input type Current input type ZSE1 ISE1 6 Same as 10 AUTO SHIFT.

VDC) Brown LINE(+) Brown DC(+) Load Main circuit Main circuit (Analog output) 1 k Black OUT 12 to 24 VDC + 12 to 24 VDC + Load Blue LINE() Blue DC() Load Install the load either on the LINE (+) or LINE () side.

Example 1) When the pressure in the rear and the front of the cylinder differs: Example 2) When the air supply is cut off and releasing the inlet pressure to the atmosphere, the residual pressure release of the outlet side can be ensured for a safety purpose. 1 1 2 12 2 1 2 1 3 1 2 1 14 2 4 12 L 10 5 1 3 How to Order ARP 30 03 BE K Option / Semi-standard: Select one each for a to f.

Example 1) When the pressure in the rear and the front of the cylinder differs: Example 2) When the air supply is cut off and releasing the inlet pressure to the atmosphere, the residual pressure release of the outlet side can be ensured for a safety purpose. 1 1 2 12 2 1 2 1 3 1 2 1 14 2 4 12 L 10 5 1 3 How to Order ARP 30 03 BE K Option / Semi-standard: Select one each for a to f.

10 C8 8(5/16) 12 10 N7 1/4 10.3 8.3 N7 1/4 10.3 8.3 PFM7-01/02--X693 PFM7S-01/02--X693 A B C() A B C() Rc1/81/4 Rc1/81/4 NPT1/81/4 NPT1/81/4 13 11 17 13 11 17 G1/8 G1/8 G1/4 17 15 21 G1/4 17 15 21 -73No.PF-OMJ0005CN-I PFM7-C4/C6/C8/N7--X694 PFM7S-C4/C6/C8/N7--X694 A B A B C4 4(5/32) 10.1 36.1 C4 4(5/32) 10.1 8.1 C6 6 10.3 36.3 C6 6 10.3 8.3 C8 8(5/16) 12 37 C8 8(5/16) 12 10 N7 1/4 10.3

V 300 24 V 600 Max.28 V80 mA 1 V C 15 V 1 k D420 mA 12 V 300 24 V 600 -18No.PF-OMN0011CN-C NPN PF3W30G PNP PF3W30H DC(+) DC(+) OUT1 OUT1 DC(-) DC(-) / / Max.80 mA 1.5 V 30 ms Max.28 V80 mA 1 V 30 ms 2 PF3W30J/PF3W30K DC(+) DC(-) / J15 V 1 k K420 mA 12 V 300 24 V 600 -19No.PF-OMN0011CN-C NPN2 PF3W30A NPN PF3W30C/PF3W30D NPN PF3W30G OUT1 OUT2(PF3W30A) DC(

-(Exanple: A53) 3m .1 (E)mple: A53L) 5n .2 (Example: A534 ' lf loot bckel is required, order 2 pcs. per cylander. " The clevis mounl @mes with clevis pin, llat washer and sPUlpin, $Ecillcalions Model Cyli nder Specif ications For Lock Unit specifications see page 8 217 PSI (1.5 MPa) 14s PSI (1.0 t\.4Pa) 12 PSI (0.08 [,4Pa) -250:'10, 251 -10O0: ia, 1001-1500:i" Basic, Foot.

Port size VCB2 VCW20-12-01A 34 40 25 30 12.8 12.8 5 4.5 6 13 1/8, 1/4 VCW30-12-02A 42 52 30 40 19 19 6 5.5 7 19 1/4, 3/8 VCB3 VCW30-12-04A Note 1) 48 56 36 44 23 23 6 5.5 7 23 1/2 VCW40-12-02A 42 52 30 40 23 23 6 5.5 7 19 1/4, 3/8 VCB4 VCW30-12-04A Note 1) 48 56 36 44 23 23 6 5.5 7 23 1/2 VCW40-12-06A 56 65 44 53 28.2 28.2 6 5.5 7 26 3/4 2 mounting screws (for mounting bracket) are included

Valve model Port size VCS21 VCW20-12-01A 1/8, 1/4 34 40 25 30 12.8 12.8 5 4.5 6 13 VCW30-12-02A 1/4, 3/8 42 52 30 40 19 19 6 5.5 7 19 VCS31 VCW30-12-04A Note 1) 1/2 48 56 36 44 23 23 6 5.5 7 23 VCW40-12-02A 1/4, 3/8 42 52 30 40 23 23 6 5.5 7 19 VCW30-12-04A Note 1) 1/2 VCS41 48 56 36 44 23 23 6 5.5 7 23 VCW40-12-06A 3/4 56 65 44 53 28.2 28.2 6 5.5 7 26 2 mounting screws (for mounting bracket

The DIN rail is approximately 30mm longer than the length of manifold. 1.25 L dimensions L=12.5n+10.5 1 6 2 9 3 12 4 15 5 18 6 21 7 24 8 27 9 30 10 33 11 36 12 39 13 42 14 45 15 47 16 50 17 53 18 56 19 59 20 62 Station No. 85.5 123 160.5 198 235.5 273 310.5 348 385.5 423 460.5 498 535.5 573 598 635.5 673 710.5 748 785.5 L DIN rail mounting bracket VVQZ100-DB-5 This bracket is used for mounting

-(Exanple: A53) 3m .1 (E)mple: A53L) 5n .2 (Example: A534 ' lf loot bckel is required, order 2 pcs. per cylander. " The clevis mounl @mes with clevis pin, llat washer and sPUlpin, $Ecillcalions Model Cyli nder Specif ications For Lock Unit specifications see page 8 217 PSI (1.5 MPa) 14s PSI (1.0 t\.4Pa) 12 PSI (0.08 [,4Pa) -250:'10, 251 -10O0: ia, 1001-1500:i" Basic, Foot.

Applicable load Type Load voltage Auto switch model Band mounting DC AC 0.5 (Nil) 1 (M) 3 (L) 5 (Z) Lead wire length (m) Wiring (Output) Electrical entry Indicator light M9B M9BW 5 V 12 V 24 V 2-wire Yes Grommet Solid state auto switch Relay, PLC A93 100 V Yes 12 V 24 V 2-wire Grommet Reed auto switch Note 2) Auto switches marked with are produced upon receipt of order.

Nil Without auto switch Symbol Position detector arms Switch bracket Positioning angle c a b c d 10 11 12 13 14 15 20 23 25 180 Refer to the table below for auto switch part numbers. X X X X X X X X X X X X 90 X b d X X X Table position detector arm X X X X X X a Switch mounting bracket X Cylinder unit/Applicable auto switch types Load voltage Lead wire length (m) Auto switch part no.

(White) (Black) OUT1 (NPN) Load Main circuit Main circuit + + 12 to 24 VDC 12 to 24 VDC OUT1 (PNP) (Black) Load OUT1 (PNP) Load (White) (Blue) DC () (Blue) DC () 16-2-49 6 Series ISE70/75/75H Description LCD display Indication light (Green) MPa Displays the switch operation status. Displays the current pressure condition, set mode and error code.

Connection thread 1/8 1/4 3/8 1/2 3/4 1 5.2 to 6.6 8.9 to 10.3 16.2 to 17.7 20.7 to 22.1 20.7 to 22.1 26.6 to 28.0 Installation and Adjustment Torque (7 to 9) (12 to 14) (22 to 24) (28 to 30) (28 to 30) (36 to 38) Warning Air Supply 1. Confirm the symbols 1 and 2 before the Warning valve is connected. The port marked 1 is the air inlet and the port marked 2 is the outlet.

V300 24 V600 Max.30 V80 mA 1 V 2815 V 1 k 29420 mA 12 V300 24 V600 -40No.PF-OMO0007CN PF2A7--28--X560 PF2A7--68--X560 PF2A7--29--X560 PF2A7--69--X560 (15 V) (420 mA) 12 V 300 24 V 600 1 k 5F.S. 1 s A B 1 V 5 V 4 mA 20 mA 1 NL/min 10 NL/min PF2A710 3.5 CFM10 -2 35.0 CFM10 -2 5 NL/min 50 NL/min PF2A750 18 CFM10 -2 176 CFM10 -2 10 NL/min 100 NL/min PF2A711 3.5 CFM10 -1 35.5 CFM10

Load voltage Lead wire length (m) Applicable load Type Special function Electrical entry Indicator light Wiring (output) Direct mounting 0.5 (Nil) 3 (L) 5 (Z) DC 3-wire (NPN) F8N U U u Solid state switch IC circuit Relay PLC 5 V 12 V Grommet (Perpendicular) 3-wire (PNP) F8P Yes 24 V U U u F8B 2-wire 12 V U U u Lead wire length symbols: 0.5 m . Nil (Example) F8N 3 m .

, double, dual 3 port valve) 5.5 5.5 35 47.5 56 10.4 2-M4 clamping screw (131.5) 147 (3 position) A A A B A B A B A B A B A B 122.3 4 A SMC 53.6 2 B 37.6 18.5 Approx. 12 Approx. 12 EXH. outlet Applicable connector: Flat cable connector (20P) (conforms to MIL-C-83503) Triangle mark indicator position Approx. 10 D side U side Station 1 2 3 4 5 6 7 8 n C10: R(EXH) port For top ports C10: P(SUP