between external terminals and case Insulation resistance 5M between external terminals and case (at 50VDC) Vibration resistance 10 to 500Hz at whichever is smaller of 1.5mm amplitude or 98m/s acceleration, in X, Y, Z directions, for 2 hours each (de-energized) 980m/s in X, Y, Z directions, 3 times each (de-energized) Impact resistance 2% F.S. or less based on the analog output value at 25C
ambient temperature) 2% F .S. 1 digit (at 25C ambient temperature) Display accuracy IF Light up when output is ON (Green) 2% F .S. or less (based on 25C) IP40 Operating: 0 to 50C, Stored: 10 to 60C (No freezing or condensation) Operating and stored: 35 to 85% RH (No condensation) 1000 VAC for 1 min. between live parts and enclosure 50 M or more between live parts and enclosure (at 500 VDC
Specification: 22 (Copper, Flourine and Silicon Free + Low Particle Generation, Vacuum Suction Type), Bore Size: Ø12, Stroke: 25mm, Adjuster: C (Metal Stopper), Magnet: W/Magnet and Rail, Auto Switch: M9NW (Solid State, 2-color Indication, 3 Wire NPN, Horizontal), Lead Wire: L (3m), Number: 3 pcs.
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Support bracket: -, Auto Switches: Without auto switch,
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Support bracket: None, Auto Switches: Without auto switch
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Support bracket: None, Auto Switches: Without auto switch
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Support bracket: None, Auto Switches: Without auto switch
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Support bracket: -, Auto Switches: Without auto switch,
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Support bracket: None, Auto Switches: Without auto switch
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Support bracket: None, Auto Switches: Without auto switch
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Support bracket: None, Auto Switches: Without auto switch
Magnet: D (Built-in), Series: 85 (Standard), Head Cover Type: N (Basic Integrated Clevis), Bore Size: 25mm, Stroke: 25mm, Cushion: C (Air Cushion), Rod Boot: None, Mounting Bracket: None, Accessory: None, Auto Switch Mounting Type: B (Band), Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal
Magnet: D (Built-in), Series: 85 (Standard), Head Cover Type: N (Basic Integrated Clevis), Bore Size: 25mm, Stroke: 25mm, Cushion: C (Air Cushion), Rod Boot: None, Mounting Bracket: None, Accessory: None, Auto Switch Mounting Type: B (Band), Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: L (3m)
Magnet: D (Built-in), Series: 85 (Standard), Head Cover Type: N (Basic Integrated Clevis), Bore Size: 25mm, Stroke: 25mm, Cushion: C (Air Cushion), Rod Boot: None, Mounting Bracket: None, Accessory: None, Auto Switch Mounting Type: B (Band), Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: SAPC (0.5m Cord Length, M8-3 Pin Connector)
Magnet: D (Built-in), Series: 85 (Standard), Head Cover Type: N (Basic Integrated Clevis), Bore Size: 16mm, Stroke: 25mm, Cushion: C (Air Cushion), Rod Boot: None, Mounting Bracket: None, Accessory: None, Auto Switch Mounting Type: B (Band), Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Environment, Applications: Standard, Support bracket: Double End Boss-cut, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number of the switches: N/A, Type of Auto Switch Mounting: N/A, Custom-made
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Environment, Applications: Standard, Operating Pressure(MPa): 0.05~1.0, Cushion: Air cushion, Support bracket: Double end, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number of the switches: N/A
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -20~80, End Locking: No, Valves: No, Cushion: Air cushion (ø10 to ø25 N only), Operating Pressure(MPa): 0.05
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -20~80, End Locking: No, Valves: No, Cushion: Air cushion (ø10 to ø25 N only), Operating Pressure(MPa): 0.05
This is a legacy product. Please contact us for the latest version.sales@ocaire.com