SMC Corporation of America
Elite Part Number Search
Search Results "CDM3E25-75-M9BL-C"

When actually mounting an auto switch, adjust the position after confirming the operating state of the auto switch. 95 Guide table10-MGF Dimensions 10-MGF40/63/100 4-N V D C D C E F H A + Stroke B + Stroke GB GA T X PP (Rc, NPT, G): Relief port 2-P(Rc, NPT, G) Port for extension Port for retraction When the cylinder is extended KA: T-slot for hexagon bolt 4-M K KB KC 6-K (6 positions) 9 9

Although switches satisfy IEC standard IP67 construction (JIS C 0920: watertight construction), do not use switches in applications where continually exposed to water splash or spray. Poor insulation or swelling of the potting resin inside switches may cause malfunction. 4. Do not use in an environment with oil or chemicals.

Flow Characteristics/Weight C [dm 3/(sbar)] b Cv C [dm 3/(sbar)] b Cv 1 2 (P A) 2 3 (A R) Valve model Flow characteristics Weight (g) Operating pressure range (MPa) Port size Grommet DIN terminal 0.10 0.13 0.13 0.10 0.13 0.13 0.13 0.13 0.13 0.13 0.41 0.32 0.32 0.41 0.32 0.59 0.32 0.32 0.59 0.32 2 3 2 3 2 3 VKF33 VKF33 Y VKF33 E VKF33 V VKF33 W VKF334 VKF334Y VKF334E VKF334V VKF334W 0.67

E C Padlock mounting position C D D Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com SUP SUP . A OUT IN A OUT IN 1 2 B 3 B EXH. EXH.

Rc 1/4 108 Head end cylinder port Rc 1/4 Dustproof cover Rod end cylinder port (Manual lock release) D (Stroke) Rc 1/8 Unlocking port IN OUT (125) (102) C B A Rc 1 DRAIN 195 (270) Dimensions (mm) A B C D Model Bore size (Nominal size B) FN111 FN112 610 (730) (844) 20 Rc 1 860 (1000) (1134) 40 8 Series FN1 Options Reservoir Dust removal filter 108 32 0 315 45 P.C.D.220 70 70 90 270 (80) 50

Power supply Single phase 200VAC (A type) or Single phase 100VAC (A1 type) MC NFB Servomotor HC-PQ C P U V W L1 U V Servo amp MR-CA or SM L2 E W MR-CA1 The cable length between the controller and servo amp is 2m or less. 24VDC Z CN1 EMG Note 7) Shuts off with alarm signal when servo ON is turned OFF.

E C Padlock mounting position C D D SUP SUP. A OUT IN A OUT IN 1 2 3 B B EXH. EXH. H 28 30 36 44 54 G 33 42 44 50 61 F 45 55 58 65 76 E 22 21 26 D 34 46 63 67 78 C 40 53 70 75 90 B 20 29 39 42 53 A 59 78 107 110 134 I 45 55 63 69 81 Model Piping port VHS20 VHS30 VHS40 VHS40-06 VHS50 1/8, 1/4 1/4, 3/8 1/4, 3/8, 1/2 3/4 3/4, 1 3

Cooling capacities: 9.5 kW, 14.5 kW, 20.5 kW (60Hz); Temperature range setting: 5 to 35°C; Temperature stability: ±0.1°C (10, 15 kW); ±1.0°C (20 kW); Power supply requirement: 3ph 380~415 VAC 50/60Hz, 3ph 460~480 VAC 60Hz; Waterproof specification: IPX4; Refrigerant: R410A (HFC); Circulating fluid: Tap or deionized water, or 15% ethylene glycol solution

Cooling capacities: 9.5 kW, 15.5 or 20.5 kW; Temperature range setting: 5 to 35°C; Temperture stability: ±1.0°C (9.5, 14.5 kW); ±1.0°C (20.4 kW); Power supply requirement: 3ph 380~415 VAC 50/60 Hz; 3ph 460~480 VAC 60Hz; Waterproof specification: IPX4; Circulating fluid: tap or deionized water or 15% ethylene glycol solution

Cooling capacities: 9.5 kW, 14.5 kW, 20.5 kW, 38 kW; Temperature range setting: 5 to 35°C; Temperature stability: ±0.1°C (10, 15, 38 kW); ±0.1°C (20 kW); Power supply requirement: 3ph 380~415 VAC 50/60Hz, 3ph 460~480 VAC 60Hz; Waterproof specification: IPX4; Refrigerant: R410A (HFC); Circulating fluid: Tap or deionized water, or 15% ethylene glycol solution

Cooling capacities: 9.5 kW, 14.5 kW, 20.5 kW (60Hz); Temperature range setting: 5 to 35°C; Temperature stability: ±0.1°C (10, 15 kW); ±1.0°C (20 kW); Power supply requirement: 3ph 380~415 VAC 50/60Hz, 3ph 460~480 VAC 60Hz; Waterproof specification: IPX4; Refrigerant: R410A (HFC); Circulating fluid: Tap or deionized water, or 15% ethylene glycol solution

Cooling capacities: 9.5 kW, 15.5 or 20.5 kW; Temperature range setting: 5 to 35°C; Temperture stability: ±1.0°C (9.5, 14.5 kW); ±1.0°C (20.4 kW); Power supply requirement: 3ph 380~415 VAC 50/60 Hz; 3ph 460~480 VAC 60Hz; Waterproof specification: IPX4; Circulating fluid: tap or deionized water or 15% ethylene glycol solution

Cooling capacities: 9.5 kW, 14.5 kW, 20.5 kW, 38 kW; Temperature range setting: 5 to 35°C; Temperature stability: ±0.1°C (10, 15, 38 kW); ±0.1°C (20 kW); Power supply requirement: 3ph 380~415 VAC 50/60Hz, 3ph 460~480 VAC 60Hz; Waterproof specification: IPX4; Refrigerant: R410A (HFC); Circulating fluid: Tap or deionized water, or 15% ethylene glycol solution

5.27 AIR PREPARATION AUTO DRAINS AUTO DRAIN SERIES (N)AD Port Sizes 14~1 Float Type Automatic Drain Valve T E C H N I C A L SPECIFICATIONS Type (N)AD402 (N)AD600 Operating Pressure 1.5~9.9 Bar 3~9.9 Bar 22~145PSI 45~145PSI Max Supply Pressure 15 Bar / 220PSI Max Operating Pressure 9.9 Bar / 145PSI Ambient & Fluid Temperature 5 ~ 60C / 40~140F Port Size 1/2 3/4, 1 Drain Port 3/4 3/4, 1 D I

L O L G H F K J E D I A B C 2-4.5 A B C D E F G H I J K L Model 4 ZFC100-04 6 ZFC100-06 53.2 9.1 30 14.1 10 18 11.6 19.5 23 20 29 5/32" ZFC101-03 1/4" ZFC101-07 6 ZFC200-06 8 ZFC200-08 67 15.5 34 17.5 14 22 15.6 23.1 27 24 35 1/4" ZFC201-07 5/16" ZFC201-09 Element Replacement Element replacement procedure 1) Stop operation and reduce the filter's internal pressure to atmosphere. 2) Turn cover

Vacuum Area Diameter (Vacuum pressure: 84 kPa) after Vacuum Suction by Vacuum Pad (mm) Flat U Flat with ribs C Bellows B Deep D Large size H Type Large size bellows HB Material Size Part no.

(Refer to graph A) No AW AMR AWM Graph C: The balance completion time Yes AWD 5 ITV No Is the cylinder speed appropriate? (Refer to graph B) 4 VBA Completion time (sec) 3 VE Yes VY 2 Use graph C as a guide for the balance completion time.

EXH system Common SUP system Common, Individual Vacuum Ejector Specifications Fluid Air 0.7 MPa 84 kPa 0.2 to 0.55 MPa 0.25 to 0.55 MPa 5 to 60 C 5 to 50 C Main valve Pilot valve Poppet VJ114, VJ324M Maximum operating pressure Maximum vacuum pressure Without valve With valve Without valve With valve Supply pressure range Operating temperature range Maximum air suction volume increased

diameter C C CN Lead wire length 0.6 m Lead wire length 3 m No lead wire 05 0.5 mm 07 0.7 mm 10 1.0 mm 13 1.3 mm 15 1.5 mm ZL Refer to Table (2) for lead wire with 4-wire connecor.

Substantial reduction of installation labor hours , Max. operating pressure: 1.0MPa , Max. operating temperature: IDF 60 C, IDU 80 C, Applicable dryer: IDF1E to 75E, IDU3E to 75E, PRESSURE SW IDFB55/75-/46(N), OTHERS, AIR PREP SPECIAL, 21, AIR PREP SPL NO SIZE RATING, 0.0616 lb