Max Operating Pressure: 4 (7 MPa), Construction: 40 (Element Upward Removal, Threaded), Port Size: 04 [1/2 Threaded, 15 (1/2) Flange SSA], Pressure Indicator: 0 (None), Relief Valve: 0 (Relief Valve), Fluid: 0 (Petroleum), Element: M (Micromesh), Filtration: 10μm, Fluid Direction: IN Left, Made to Order: X0 (Non-standard Filtration)
Max Operating Pressure: 4 (7 MPa), Construction: 40 (Element Upward Removal, Threaded), Port Size: 06 [3/4 Threaded, 20 (3/4) Flange SSA], Pressure Indicator: 0 (None), Relief Valve: 1 (None), Fluid: 0 (Petroleum), Element: P (Paper), Filtration: 5μm, Fluid Direction: L (IN Right)
Max Operating Pressure: 4 (7 MPa), Construction: 40 (Element Upward Removal, Threaded), Port Size: 08 [1 Threaded, 25 (1) Flange SSA], Pressure Indicator: 1 (Differential Pressure Indicator), Relief Valve: 0 (Relief Valve), Fluid: 0 (Petroleum), Element: P (Paper), Filtration: 10μm
Max Operating Pressure: 4 (7 MPa), Construction: 40 (Element Upward Removal, Threaded), Port Size: 04 [1/2 Threaded, 15 (1/2) Flange SSA], Pressure Indicator: 0 (None), Relief Valve: 0 (Relief Valve), Fluid: 0 (Petroleum), Element: P (Paper), Filtration: 10μm
Max Operating Pressure: 4 (7 MPa), Construction: 40 (Element Upward Removal, Threaded), Port Size: 04 [1/2 Threaded, 15 (1/2) Flange SSA], Pressure Indicator: 1 (Differential Pressure Indicator), Relief Valve: 0 (Relief Valve), Fluid: 0 (Petroleum), Element: P (Paper), Filtration: 10μm
Max Operating Pressure: 4 (7 MPa), Construction: 40 (Element Upward Removal, Threaded), Port Size: 10 [1 1/4 Threaded, 32 (1 1/4) Flange SSA], Pressure Indicator: 2 (Differential Pressure Indication Switch), Relief Valve: 1 (None), Fluid: 1 (Water-glycol, Emulsion), Element: M (Micromesh), Filtration: 40μm, Fluid Direction: IN Left, Made to Order: X0 (Non-standard Filtration)
Max Operating Pressure: 4 (7 MPa), Construction: 40 (Element Upward Removal, Threaded), Port Size: 08 [1 Threaded, 25 (1) Flange SSA], Pressure Indicator: 2 (Differential Pressure Indication Switch), Relief Valve: 0 (Relief Valve), Fluid: 1 (Water-glycol, Emulsion), Element: M (Micromesh), Filtration: 40μm, Fluid Direction: IN Left, Made to Order: X0 (Non-standard Filtration)
Max Operating Pressure: 4 (7 MPa), Construction: 40 (Element Upward Removal, Threaded), Port Size: 06 [3/4 Threaded, 20 (3/4) Flange SSA], Pressure Indicator: 1 (Differential Pressure Indicator), Relief Valve: 1 (None), Fluid: 1 (Water-glycol, Emulsion), Element: P (Paper), Filtration: 10μm, Fluid Direction: L (IN Right)
Max Operating Pressure: 4 (7 MPa), Construction: 40 (Element Upward Removal, Threaded), Port Size: 06 [3/4 Threaded, 20 (3/4) Flange SSA], Pressure Indicator: 1 (Differential Pressure Indicator), Relief Valve: 0 (Relief Valve), Fluid: 0 (Petroleum), Element: P (Paper), Filtration: 10μm
Max Operating Pressure: 4 (7 MPa), Construction: 40 (Element Upward Removal, Threaded), Port Size: 06 [3/4 Threaded, 20 (3/4) Flange SSA], Pressure Indicator: 0 (None), Relief Valve: 0 (Relief Valve), Fluid: 0 (Petroleum), Element: M (Micromesh), Filtration: 105μm, Fluid Direction: IN Left, Made to Order: X0 (Non-standard Filtration)
Max Operating Pressure: 4 (7 MPa), Construction: 40 (Element Upward Removal, Threaded), Port Size: 10 [1 1/4 Threaded, 32 (1 1/4) Flange SSA], Pressure Indicator: 2 (Differential Pressure Indication Switch), Relief Valve: 0 (Relief Valve), Fluid: 1 (Water-glycol, Emulsion), Element: M (Micromesh), Filtration: 10μm, Fluid Direction: IN Left, Made to Order: X0 (Non-standard Filtration)
Max Operating Pressure: 4 (7 MPa), Construction: 40 (Element Upward Removal, Threaded), Port Size: 06 [3/4 Threaded, 20 (3/4) Flange SSA], Pressure Indicator: 2 (Differential Pressure Indication Switch), Relief Valve: 1 (None), Fluid: 0 (Petroleum), Element: P (Paper), Filtration: 5μm
Max Operating Pressure: 4 (7 MPa), Construction: 40 (Element Upward Removal, Threaded), Port Size: 06 [3/4 Threaded, 20 (3/4) Flange SSA], Pressure Indicator: 1 (Differential Pressure Indicator), Relief Valve: 1 (None), Fluid: 0 (Petroleum), Element: P (Paper), Filtration: 10μm
Max Operating Pressure: 4 (7 MPa), Construction: 40 (Element Upward Removal, Threaded), Port Size: 08 [1 Threaded, 25 (1) Flange SSA], Pressure Indicator: 1 (Differential Pressure Indicator), Relief Valve: 0 (Relief Valve), Fluid: 1 (Water-glycol, Emulsion), Element: M (Micromesh), Filtration: 40μm, Fluid Direction: IN Left, Made to Order: X0 (Non-standard Filtration)
Max Operating Pressure: 4 (7 MPa), Construction: 40 (Element Upward Removal, Threaded), Port Size: 08 [1 Threaded, 25 (1) Flange SSA], Pressure Indicator: 2 (Differential Pressure Indication Switch), Relief Valve: 1 (None), Fluid: 1 (Water-glycol, Emulsion), Element: M (Micromesh), Filtration: 40μm, Fluid Direction: IN Left, Made to Order: X0 (Non-standard Filtration)
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, HYDRAULIC FILTER, OTHERS, FHG HYDRAULIC FILTER, JX, FHG 1 1/2INCH (MISC./OTHER), 23.14853 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, FILTER, HYDRAULIC, OTHERS, FHG HYDRAULIC FILTER, IX, FHG 1 1/4INCH (MISC./OTHER), 16.53466 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, HYDRAULIC FILTER, OTHERS, FHG HYDRAULIC FILTER, HX, FHG 1 INCH (MISC./OTHER), 16.21133 lb
FH series suction filters are compact and lightweight. Designed with an aluminum casted housing. Element can be replaced by simply opening the cover to detach the element without touching the pipes. The filter can be fitted with a differential pressure indicator which senses when the element is becoming dirty, facilitating maintenance and helping to avoid pump damage such as cavitations.
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, HYDRAULIC FILTER, OTHERS, FHG HYDRAULIC FILTER, HX, FHG 1 INCH (MISC./OTHER), 15.17147 lb, Port sizeModelBolt dimensionFlange (JIS B2291)O-ring (JIS B240-1-A)20FH441M20 x 2.5 x 65SSA65G75