Cooling Capacity: 15 kW, Cooling Method: Water-cooled, Pipe Thread: N [NPT, (w/Rc-NPT conversion Fitting)], Option: w/Earth Leakage Breaker w/Handle and w/Fluid Fill Port
Cooling Capacity: 15 kW, Cooling Method: Water-cooled, Pipe Thread: N [NPT, (w/Rc-NPT conversion Fitting)], Option: w/Earth Leakage Breaker w/Handle and w/Fluid Fill Port and SI Unit Only
Cooling Capacity: 15 kW, Cooling Method: Water-cooled, Pipe Thread: N [NPT, (w/Rc-NPT conversion Fitting)], Option: w/Caster Adjuster-foot and w/Fluid Fill Port, Manual Fill
Cooling Capacity: 150, Thread Type: F [G (w/Rc-G Conversion Fitting)], Power Supply: 46 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], Option 1: w/Fluid Fill Port, UL Certification: -, Option 2: -
Cooling Capacity: 15 kW, Cooling Method: Water-cooled, Pipe Thread: NPT, w/Rc-NPT Conversion Fitting, Power Supply: 46 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460-480 VAC (60 Hz)], Option: w/Caster Adjuster-foot and Fluid Fill Port
Cooling Capacity: 150 (15 kW), Cooling Method: W (Water-cooled), Pipe Thread: N [NPT, (w/Rc-NPT conversion Fitting)], Option: AB1K (w/Caster Adjuster Foot and w/Earth Leakage Breaker w/Handle and w/Fluid Fill Port)
Cooling Capacity: 150 (15 kW), Cooling Method: W (Water-cooled), Pipe Thread: N [NPT, (w/Rc-NPT conversion Fitting)], Option: ABK (w/Caster Adjuster-foot, w/Earth Leakage Breaker, and Fluid Fill Port)
Cooling Capacity: 150 (15 kW), Cooling Method: W (Water-cooled), Pipe Thread: N [NPT, (w/Rc-NPT conversion Fitting)], Option: K (w/Fluid Fill Port, Manual Fill)
Cooling Capacity: 150 (15 kW), Cooling Method: W (Water-cooled), Pipe Thread: Rc, Option: ABK (w/Caster Adjuster-foot, w/Earth Leakage Breaker, and Fluid Fill Port)
Cooling Capacity: 150 (15 kW), Cooling Method: W (Water-cooled), Pipe Thread: F [G, (w/Rc-G Conversion Fitting)], Option: AK (w/Caster Adjuster-foot and w/Fluid Fill Port, Manual Fill)
Cooling Capacity: 150 (15 kW), Cooling Method: W (Water-cooled), Pipe Thread: N [NPT, (w/Rc-NPT conversion Fitting)], Option: B1 (w/Earth Leakage Breaker w/Handle)
Cooling Capacity: 150 (15 kW), Cooling Method: W (Water-cooled), Pipe Thread: N [NPT, (w/Rc-NPT conversion Fitting)], Option: AB1 (w/Caster Adjuster Foot and w/Earth Leakage Breaker w/Handle)
Cooling Capacity: 150 (15 kW), Cooling Method: W (Water-cooled), Pipe Thread: N [NPT, (w/Rc-NPT conversion Fitting)], Option: AB1KW (w/Caster Adjuster Foot and w/Earth Leakage Breaker w/Handle and w/Fluid Fill Port and SI Unit Only)
Cooling Capacity: 150 (15 kW), Cooling Method: W (Water-cooled), Pipe Thread: N [NPT, (w/Rc-NPT conversion Fitting)], Option: B1K (w/Earth Leakage Breaker w/Handle and w/Fluid Fill Port)
Cooling Capacity: 150 (15 kW), Cooling Method: W (Water-cooled), Pipe Thread: N [NPT, (w/Rc-NPT conversion Fitting)], Option: B1KW (w/Earth Leakage Breaker w/Handle and w/Fluid Fill Port and SI Unit Only)
Cooling Capacity: 150 (15 kW), Cooling Method: W (Water-cooled), Pipe Thread: N [NPT, (w/Rc-NPT conversion Fitting)], Option: AK (w/Caster Adjuster-foot and w/Fluid Fill Port, Manual Fill)
Cooling Capacity: 150 (15 kW), Cooling Method: A (Air-cooled), Pipe Thread: F [G, (w/Rc-G Conversion Fitting)], Option: AK (w/Caster Adjuster-foot and w/Fluid Fill Port, Manual Fill)
If these items need to be supported, provide an additional support. t A Class 2 Pressure Vessel Pressure Resistance Certificate is provided with those below, which are considered to be Class 2 pressure vessels. Make sure to store the certificate in a safe location.
Use caution, as there is a danger of being burned if a valve is touched directly. 2. Valves may reach high temperatures when continuously energized. Use caution, as there is a danger of being burned if a valve is touched directly. SOL. AC AC SOL. Without light AC SOL.
The maximum protrusion of an auto switch (when fingers are fully closed) from the edge of the body is shown in the table below. Use the table as a guideline for mounting. Auto switch mounting bracket part no. BMG2-012 Auto switch part no. D-M9(V)/M9W(V)/M9A(V) Note) Use a screwdriver with a grip diameter of 5 to 6 mm to tighten the set screws (M2.5).