Note 2) AS1000, AS2000 are not applicable. 8 3 2 1 Bore size 2 1 Bore size Applicable series M3 M5 01 02 03 04 M3 x 0.5 M5 x 0.8 Rc 1/8 Rc 1/4 Rc 3/8 Rc 1/2 AS1000 AS1000 AS2000 AS2000/3000/4000/5000 AS3000/4000/5000 AS4000/5000 Thread type Nil Metric thread (M3, M5) Rc NPT G N F Caution Be sure to read before handling.
Refer to pages 15-18-3 to 15-18-4 for Safety Instructions and Common Precautions on the products mentioned in this catalog, and refer to pages 15-8-6 to 15-8-8 for Precautions on every series. 3 Construction w r y t u !2 e !1 No. q w e r t y u i o !0 !1 !
The standard lead wire length IS 06m.Grommet L IS added for 3m long lead wire (Example) ZSE4B-Ol -25L Port size: 01 stands for R(PT)1/8 and TI tor NPTF1 /8 Both types have M5X0.8 female threads InSide, Option (Available separately) Panel mount adaptor No.
(n1L~n1H n2L~n2H) ON (20 ) Hysteresis "" 20 ON () (P1LP1H P2LP2H) ON (20 ) () 5%R.D.(5%) (0~1MPa 0.001MPa 1/1000) "()" () "" () ripple -12No.PS-OMH0005CN-D M38 L(2) (ZS-26-B) +(ZS-26-01) 48(ZS-26-D) 48 (ZS-26-D) () (ZS-26-01) (ZS-26-B) 90 IP65(48IP40) 1/41/2 0.58 mm -13No.PS-OMH0005CN-D 2 -14No.PS-OMH0005CN-D FG () AWG No.
Alarm1 Water Leak Detect FLT 01 Alarm2*1 02 Alarm3 RFGT High Press FLT 03 Alarm4*1 04 Alarm5 Reservoir Low Level FLT 05 Alarm6 Reservoir Low Level WRN 06 Alarm7 Reservoir High Level WRN 07 Alarm8 Temp. Fuse Cutout FLT 08 Alarm9 Reservoir High Temp. FLT 09 Alarm10*1 10 Alarm11 Reservoir High Temp.
IR1000 : G33-2-01 G33-P2-N01-X30 IR1010 : G33-4-01 G33-P4-N01-X30 IR1020 : G33-10-01 G33-P10-N01-X30 Set pressure Thread type NIL:Rc N:NPT 0: 0.005~0.2MPa 1: 0.01~0.4MPa 2: 0.01~0.8MPa F:G 4. Marking on product Product name plate Production lot no. MAX.SUP.PRESS. MAX.SUP.PRESS. MAX.SUP.PRESS. MAX.SUP.PRESS. 1.0 1.0 1.0 1.0 MPa MPa MPa MPa OUTPUT PRESS. OUTPUT PRESS. OUTPUT PRESS.
R The pressure range in which the Pressure switch meets the specifications. Values outside of this range can be set if they are within the set pressure range, but cannot be guaranteed to meet the product specifications. Rated pressure range The value currently displayed.
exhaust center Closed center Exhaust center Silencer (AN101-01) Component Parts No.
Options: SET Priority, RESET Priority Inputs: S> (Set) R> (Reset) Output: ON/OFF 6.3 The PULSE Block The PULSE Block sends a single pulse at any the following times (chosen by the user): the Input pin receives an ON signal, the Input signal turns OFF, or Both.
Meter-out: Gray Meter-in: Light blue 23 3.2 Note 2) 01 1/8" 03 5/32" 07 1/4" 09 5/16" 11 3/8" 13 1/2" ASR ASQ 04 4 06 6 08 8 10 10 12 12 16 16 Thread type Nil R N NPT Note 1) For selecting applicable tubing O.D., refer to the Model on page 554. Note 2) Use 1/8" tube. Port size 01 1/8 02 1/4 03 3/8 04 1/2 Made to Order (For details, refer to page 562.)
Note 3) Only the metric size is available for the G thread type. 1 180 Indicator window Port size Indicator window 01 1/8 02 1/4 03 3/8 04 1/2 2 90 Thread type 3 270 Nil R N NPT G G Indicator window Note) Orientation of indicator direction is xed when manufacturing, and cannot be changed by the user. In addition, the universal type is only available with 180 setting. 5
Thread type Nil R N NPT G G Port size 01 1/8 02 1/4 03 3/8 04 1/2 Made to Order (For details, refer to page 678.) Symbol Specications -X12 Lubricant: Vaseline -X21 Grease-free (Seal: Fluorine-coated) + Restrictor (Without check valve) -X214 Restrictor (Without check valve) 10Clean Series 668 A
Series VXK21/22/23 Direct Operated 2 Port Solenoid Valve with Built-in Y-strainer For Air/Single Unit How to Order (Single Unit) Specifications For Air For Water For Oil For Steam Dimensions Construction VXK 2 21 01 VXK 2 21 01 1 G 0 0 1 G R 1 5 AC DC Model Refer to the Table (1) shown below for availability. Bracket Orifice size Refer to the Table (1) shown below for availability.
(mm)Connection threadsModel Elbow typeUniversal type Meter-outMeter-inMeter-outMeter-in6R 1/8AS2201FG-01-06AS2211FG-01-06AS2301FG-01-06AS2311FG-01-06
How to Order 30 M BE 02 03 K AR D Common supply Symbol Description Body size 20 30 40 Nil With backflow function Without backflow function With backflow function Nil c Thread type 01 Port size (IN) 02 03 04 01 Port size (OUT) 02 Note 1) 03 Nil Without mounting option B With bracket a Mounting H With set nut (for panel mount) Nil Without pressure gauge Note 2) Note 2) Square embedded type
3) 1 1 () -3No.PS-OMH0002CN-D () () () () -4No.PS-OMH0002CN-D () * (ISE70 ) SUS630SUS430SUS304 (ISE75(H)) ON/OFF (ISE70 ) (10 10 ) UL1310 UL1585 UL -5No.PS-OMH0002CN-D * (50 N ) , ,ISE70 40 NmISE75(H)80 Nm 1.52 FG *() 6 33 2 () ( etc.) 10 m10 m DC(-)() -6No.PS-OMH0002CN-D * () CE (FKM) * 2030 1 LCD * ()(), (ISE70 ) O -7No.PS-OMH0002CN-D ISE ISE ISE ISE ISE ISE ISE ISE 70 01
Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 01 (R 1/8)
Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 01 (R 1/8)
Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 01 (R 1/8)
Output Specification: X (NPN Open Collector 2 Outputs + Copy Function), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 01 (R 1/8)