P + 0.1 0.1 QCR = 2V x x 10P 0.1 QCP = 2 x a x l x x 10QC = QCR + QCP Formula QC2 = QC x n x Number of actuators x Reserve factor QCR = Air consumption of Mini-Rotary Actuator [l (ANR)] QC2 = Compressor discharge flow rate n = Actuator reciprocations per minute QCP = Air consumption of tubing or piping [l (ANR)] V = Internal volume of Mini-Rotary Actuator [cm] Internal cross section of tubing

P + 0.1 0.1 QCR = 2V x x 10P 0.1 QCP = 2 x a x l x x 10QC = QCR + QCP Formula QC2 = QC x n x Number of actuators x Reserve factor QCR = Air consumption of Mini-Rotary Actuator [l (ANR)] QC2 = Compressor discharge flow rate n = Actuator reciprocations per minute QCP = Air consumption of tubing or piping [l (ANR)] V = Internal volume of Mini-Rotary Actuator [cm] Internal cross section of tubing

PA+w x PC F=q x PA+(e-q) x PC F=-q x PA+r x PB+(w-e) x PC F=q x PA q, w and e are piston areas.

Fluid JIS Symbol OUT Option (1) Made to Order (2) Standard specifications Water (Standard) Turbine oil High temperature water (D, E, N, P) High temperature oil (D, N) Air X44 Vacuum (up to 1.3 x 102 Pa) X44 Note 1) Refer to page 17-3-9 Applicable Fluids Check List for details of special fluids outside of the standard options and specifications. Note 2) Please contact SMC for details.

Outside Local Area: (800) 258-9200-www.stevenengineering.com ZSP ISA2 IS ZSM PF2 01: R 1/8 T1: NPTF 1/8 IF 2-3.5 Mounting hole 13 Data M5 x 0.8 Connector type 30 SE3C I Z 01 T1 20.5 RESET button DOWN button SET button UP button Lead wire length 600 39 8.5 3.5 (3000) 10 01: R 1/8 T1: NPTF 1/8 2-3.5 Mounting hole 13 M5 x 0.8 16-4-7 8 Series ZSE3/ISE3 Dimensions/Switch Only Grommet type ZSE3

10-5 cm3 (cc) 0.0610 m3 35.320 L 0.0353 L 0.2642 Weight g 0.0353 kg 2.2046 1.356 N . m 1.356 J 3.6 l\rJ mm3 cm3 (cc) m3 L L rn3 in3 Energy ft3 N. m f t 3 J gar(u.s.)

Corrected air flow = (Air flow) (Data A x Data C) Corrected air flow = (Air flow) (Data B x Data C) 3 Select a model having an air flow capacity that is higher than the corrected air flow. IDF selection example IDU selection example The procedure for selecting the optimum model under the following conditions is shown below.

Y, Z directions for 2hrs. each (deenergized) 980m/s (100G) in X, Y, Z directions 3 times each (deenergized) In a temperature range of 0 to 50C, 2% F.S. or less of pressure measured at 25C Vibration resistance Impact resistance Temperature characteristics 01: R1/8, M5 x 0.8, T1: NPT1/8, M5 x 0.8, W1: Rc1/8 C4: With 4 One-touch fitting, C6: With 6 One-touch fitting, M5: M5 female threads 5

Operating port 2 x M3 x 0.5 I J Vacuum port M3 x 0.5 3.5 (Plugged when the product is a symmetric type.) 4 3 8 K 4 x M3 x 0.5 thread depth 5.5 Note 2) Note 3) 2 x M3 x 0.5 thread depth 3.5 17 5 Note 1) When using a positioning pin, use a stepped positioning pin. For details, please consult with your SMC sales representative.

Type AS1200-M3 Direct cylinder elbow type 2 Bore size JIS Symbol Direct cylinder flat elbow type 4 Symbol Bore size Applicable series Control type AS1200-M3 AS1400-M3 M3 M3 x 0.5 Meter-out Meter-in 0 1 AS120-M5 AS120-U10/32 AS220-01 AS220-02 AS320-03 AS420-04 M5 x 0.8 10-32UNF 1/8 1/4 3/8 1/2 M5 U10/32 01 02 03 04 P.15-11-3 Thread type Cylinder side R Tube side Rc Symbol Metric thread (M3

4 x M8 I Minimum fluid level 6 x M8 135 170 Minimum fluid level Body mounting: Cut-out processing of the window is required for the customers tank.

Electrical entry q Description 01 02 03 01 02 03 01 02 03 Mounting bolt and gasket are not included. Platinum silver Body C: Conduit VS4010-CSSub-plate Platinum silver Aluminum die-casted w T: Conduit terminal VS4010-TSSpool/Sleeve Stainless steel e U: Grommet, D: DIN terminal VS4010-SReplacement Parts Part no. No.

SI Unit for VQC/S0700 Series Valves ( EX500-Q 01 ) SI Unit for SV Series Valves ( EX500-S 01 ) M3 28: 4 pcs. ( Plus-minus slot round head screw ) Supply/exhaust block assembly Supply/exhaust block assembly 1.

1.25 M12 x 1.25 M16 x 1.5 M16 x 1.5 M20 x 1.5 M20 x 1.5 Ports G1/8 G1/4 G1/4 G3/8 G3/8 G1/2 Cushioning stroke [mm] 19 19 24 24 30 30 Mounting position Any Standard strokes [mm] 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600, 700, 800 (DIN ISO 4393) [mm] Other stroke lengths in accordance with ISO 497 R 10 Stroke tolerance [mm] <250mm: +1.0/-0mm, <1000mm: +1.4/-0mm Working pressure

Refer to p.0-26 and 0-27 for Safety Instructions and common precautions on the products mentioned in this catalog, and refer to p.3.0-7 to 3.0-9 for precautions on every series.

M3 Port size With One-touch fitting AS M3 x 0.5 M5 x 0.8 10-32 UNF 1/8 1/4 3/8 1/2 M5 Thread type U10/32 01 02 03 04 ASP R Unified thread (10-32 UNF) Metric thread (M3, M5) Nil ASN N NPT AQ ASV Needle Valve/Flow Characteristics AK AS1201F-M5, AS1211F-M5 AS1301F-M5, AS1311F-M5 AS2201F-01, AS2211F-01 AS2301F-01, AS2311F-01 AS1201F-M3, AS1211F-M3 AS1301F-M3, AS1311F-M3 ASS Inlet pressure: 0.5

) 2 to 60 psig (0.014 to 0.4 MPa) 5 to 100 psig (0.034 to 0.7 MPa) 15 to 200 psig (0.1 to 1.4 MPa) 15 to 300 psig (0.1 to 2.1 MPa) Code Bonnet Standard Panel installation 3) 01 02 06 10 20 30 No code P Connections (Inletq, Outletw) 3) Panel mounting hole: dia. 1.42 inch (36.1 mm).

1.25 10 12 14 M14 x 1.5 8 M8 x 1.25 10 12 14 M14 x 1.5 M10 x 1.25 M10 x 1.25 JIS class 2 +1.4 0 mm M5 x 0.8 Specific Product Precautions Be sure to read before handling.