SMC Corporation of America
Elite Part Number Search
Search Results "ISE20B-Y-01-WA1"

Controller Mounting: D (DIN Rail Mouting), Cable Length: 1 (1 m), Inlet Port Silencer: B (ANB1-01, 55 dB), Digital Pressure Switch: P (ISE20A-Y-01-J-X603)

Pod NVF3000 NVF5000 Supply SUP Cylindet cYL.1, CYL.2 A , B Exhaust EXH.1, EXH.2 Rl, R2 Symbol (SirEle solenoid) l c 1 : c Y L . 1 l IC2:CYL.2 lEl :EXH.r I {E2:EXH.2] Lubricant 1.

Controller Mounting: S (Screw Mounting), Cable Length: 1 (1 m), Inlet Port Silencer: A (AN10-01, 62 dB), Digital Pressure Switch: P (ISE20A-Y-01-J-X603)

Controller Mounting: D (DIN Rail Mouting), Cable Length: 1 (1 m), Inlet Port Silencer: A (AN10-01, 62 dB), Digital Pressure Switch: P (ISE20A-Y-01-J-X603), Exhaust Check Valve: K (AKH06-00, for 6mm tubing), Exhaust Solenoid Valve: V (V124-5LU-M5)

Controller Mounting: S (Screw Mounting), Cable Length: 1 (1 m), Inlet Port Silencer: B (ANB1-01, 55 dB), Digital Pressure Switch: P (ISE20A-Y-01-J-X603), Exhaust Check Valve: K (AKH06-00, for 6mm tubing)

IDH Component Parts ID Threaded type Threaded type IDG Manual operation valve (with lever lock) IDK AMG Lead wire with L-type connector AFF With flow adjuster With differential pressure indicator AM PB AMD One-touch fitting One-touch fitting PA AMH AME u t q w e r y AMF No. Description Individual part no.

Different units (mm, inch, degree, and PLS) are applicable to different systems: mminch X-Y table, conveyor (Select mm or inch depending on the machine specifications) degree Rotating body (360 degrees/rotation) PLS X-Y table, conveyor When you change the unit, note that the values of other parameters and data will not be changed automatically.

10 to 60C (No freezing or condensation)Operating/Stored: 35 to 85% RH (No condensation)1000 VAC for 1 minute between live parts and case50 M or more between live parts and case (at 500 VDC Mega)10 to 150 Hz at whichever is smaller of 1.5 mm amplitude or 20 m/s2 acceleration, in X, Y, Z directions, for 2 hours each (Non-energized)100 m/s2 in X, Y, Z directions, 3 times each (Non-energized

10 to 60C (No freezing or condensation)Operating/Stored: 35 to 85% RH (No condensation)1000 VAC for 1 minute between live parts and case50 M or more between live parts and case (at 500 VDC Mega)10 to 150 Hz at whichever is smaller of 1.5 mm amplitude or 20 m/s2 acceleration, in X, Y, Z directions, for 2 hours each (Non-energized)100 m/s2 in X, Y, Z directions, 3 times each (Non-energized

Function: 1 (2 Position Single), Piping: 3 (Body Ported), Exhaust: 0 (Individual), Low Wattage: Y (Low Wattage Type), Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 5 (24VDC), Lead Wire: Y (DIN EN175301-803 Terminal w/Connector), Light/Surge Suppressor: Without light/surge voltage suppressor, Manual Override: Non-locking Push Type, A, B Port Size: 01 (1/

Function: 1 (2 Position Single), Piping: 3 (Body Ported), Exhaust: 0 (Individual), Low Wattage: Y (Low Wattage Type), Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 5 (24VDC), Lead Wire: Y (DIN EN175301-803 Terminal w/Connector), Light/Surge Suppressor: Z (With light/surge voltage suppressor), Manual Override: Non-locking Push Type, A, B Port Size: 01 (1