Pressure Range: 0 to 1 MPa, Piping: Rc 1/4, Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Right-angled, 5 m, Bracket: Bracket B, Operation Manual/Calibration Certificate: -

Pressure Range: 0 to 1 MPa, Piping: Rc 1/4, Orifice: None, Unit Specification: SI Unit Only, Lead Wire: Lead Wire with M12 Connector; Right-angled, 5 m, Bracket: Bracket A, Interchangeable with ISE75[H], Operation Manual/Calibration Certificate: -

Pressure Range: 0 to 16 MPa, Piping: Rc 1/4, Orifice: None, Unit Specification: SI Unit Only, Lead Wire: Lead Wire with M12 Connector; Right-angled, 5 m, Bracket: -, Operation Manual/Calibration Certificate: -

Pressure Range: 0 to 16 MPa, Piping: Rc 1/4, Orifice: None, Unit Specification: SI Unit Only, Lead Wire: -, Bracket: -, Operation Manual/Calibration Certificate: -

Pressure Range: 0 to 16 MPa, Piping: Rc 1/4, Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Right-angled, 5 m, Bracket: Bracket A, Interchangeable with ISE75[H], Operation Manual/Calibration Certificate: -

Pressure Range: 0 to 16 MPa, Piping: Rc 1/4, Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Right-angled, 5 m, Bracket: -, Operation Manual/Calibration Certificate: -

Pressure Range: 0 to 2 MPa, Piping: Rc 1/4, Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Right-angled, 5 m, Bracket: Bracket A, Interchangeable with ISE75[H], Operation Manual/Calibration Certificate: -

Pressure Range: 0 to 2 MPa, Piping: Rc 1/4, Orifice: None, Unit Specification: SI Unit Only, Lead Wire: Lead Wire with M12 Connector; Right-angled, 5 m, Bracket: -, Operation Manual/Calibration Certificate: -

Pressure Range: 0 to 2 MPa, Piping: Rc 1/4, Orifice: None, Unit Specification: SI Unit Only, Lead Wire: -, Bracket: -, Operation Manual/Calibration Certificate: -

Pressure Range: 0 to 5 MPa, Piping: Rc 1/4, Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Straight, 5 m, Bracket: -, Operation Manual/Calibration Certificate: -

Pressure Range: 0 to 16 MPa, Piping: Rc 1/4, Orifice: None, Unit Specification: SI Unit Only, Lead Wire: Lead Wire with M12 Connector; Right-angled, 5 m, Bracket: Bracket A, Interchangeable with ISE75[H], Operation Manual/Calibration Certificate: -

PF2M7-B.eng:PF2M7-B.eng.qxd 21/04/09 14:02 1 Before Use Digital Flow Switch PF2M7## Wiring Wiring of connector Connections should only be made with the power supply turned off. Use separate routes for the product wiring and any power or high voltage wiring. Otherwise, malfunction may result due to noise.

Positive response Customer's system This product (controller) (device) Request messagePositive responseRequest messageNegative responseRequest message Based on the request message, reads/writes register and returns a positive response. 10 to 200 ms Response messageResponse message Negative response Returns a negative message when the received request message is not normal.

After cleaning the filter, return it to the product. 0 to 250 ms 0ms times of If the trouble cannot be solved even after restart, temperature sensor need to be replaced. 5 7 0.10 to 10.00 times. AL2 Temperature sensor breaks. P1 set Set with [] or [] key value If the trouble cannot be solved even after restart, temperature sensor need to be replaced.

Note 3) When removing a straight-type fitting from a valve, after removing the clip, attach tubing or a plug (KJP-02, KQ2P) to the One-touch fitting, and pull it out while holding the tubing or plug. If it is pulled out while holding the release button of the fitting (resin part), the release button may be damaged.

B H NTJ-015A NT-02 NT-04 NT-05 M5 x 0.8 7.8 9.2 12 8 4 H B M8 x 1.25 12.5 15.0 20 13 5 M14 x 1.5 21.0 25.4 32, 40 22 8 M18 x 1.5 26 31.2 50, 63 27 11 Electrical Wiring Input/Output The input/output of the scale cylinder is performed by a 7 shielded twisted pair wire from the sensor section plus a connector.

The maximum detectable piston speed is: Auto switch operating range (mm) _ Load operating time (ms) Operating current of load (OFF condition) > Leakage current V (mm/s) = x 1000 If the criteria given in the above formula are not met, it will not reset correctly (stays ON). Use a 3 wire switch if this specification will not be satisfied.

VQZ300 Port size Symbol VQZ200 VZ 1 One-touch fitting for 4 One-touch fitting for 6 One-touch fitting for 8 One-touch fitting for 10 M5 thread Rc (PT)1/4 C4 C6 C8 C10 M5 02 Metal seal Rubber seal 1 (P) 3 (R) VT (A) 2 N.O. 2 VT 1 (P) 3 (R) Note 1) Refer to p.2.10-18 for inch size Onetouch fittings. VP (A) 2 N.C. 3 VG 1 (P) 3 (R) Manual override (A) 2 N.O.

Factor: 0.9 Effective area Non voltage input (0V/Between respective input: Short or open) and Analog voltage input (RUN1 input during external input operation) Input 40 ms or less Response time Start (START) Reset (RESET) Detecting switch of cylinder motion (SW) Emergency stop (STOP) Operation 1 (RUN 1) Operation 2 (RUN 2) Prepared (READY) Balance pressure setting precision 0.75%FS (After

P1: 0.05 to 0.9 MPa P2: 0.2 to 0.9 MPa Pilot pressure (Air operated: P2, P3: 0.2 to 0.9 MPa P2 P3) 0.01 MPa 0.01 MPa Repeatability Sensitivity Response time Max. operating frequency 60 ms or less 3 cycles/sec. 6 turns 8 turns Free Not required (Use turbine oil Class 1 ISO VG32, if lubricated.)