Note 2) Refer to the specifications of display unit for the flow rate value per pulse. 340 Clean Air Module LLB Series Dimensions LLB3-1-PRVSF V2 49.5 HAA HAW Mounting hole for 4 x M4 AT 45 37 35 IDF IDU 1.5 4 20.5 278.5 50 IDF FS A Valve open and locked position Rc 1/4 (NPT 1/4) Rc 1/4 (NPT 1/4) IDFA 90 (Lever operating direction) Max. 91 IDFB A Hand valve Valve closed position 5.5 39 IDH
25 32 40 4 4 5.5 M6 X 1 3.5 60 25 26 54 M8 X 1.25 depth14 35 80 105 50 93 12 M5 X 0.8 MGP 7 7 9 4 70 32 31 62 40 95 60 12 M10 X 1.5 depth18 125 M8 X 1.25 103 M5 X 0.8 Rc(PT)1/8 Rc(PT)1/8 7 7 9 4 70 32 38 62 40 95 60 12 M10 X 1.5 depth18 125 M8 X 1.25 104 MGQ 8 8 11 4 38 47 67 45 75 12 150 M8 X 1.25 115 M12 X 1.75 depth 21 82.5 115 MGG Bore size (mm) WH U W Y T V Wq Z X 20 25 32 40 23 50
Replace XXX with flow rate using 3 digits, example 50 slpm = "050" Adjustable Range: AP3571= 10 to 200 slpm, AP4571= 10 to 350 slpm Model Mode Two step mode Status Code Normally closed (N.C.)
Without lead wire: (with connector and 2 of sockets only) SY100-30-A Rated voltage Lead wire length 5 6 V S R 1 2 24 VDC 12 VDC 6 VDC 5 VDC 3 VDC 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz [115 VAC 50/60 Hz] Nil 6 10 15 20 25 30 50 300 mm 600 mm 1000 mm 1500 mm 2000 mm 2500 mm 3000 mm 5000 mm Electrical entry G H L LN LO M MN MO W0 Grommet, 300 mm lead wire Grommet, 600 mm lead wire
50 (mg/L) 200 50 50 [pH4.8](mgCaCO3/L) 100 50 50 (mgCaCO3/L) 200 70 70 (mgCaCO3/L) 150 50 50 (mgSiO2/L) 50 30 30 (mg/L) 1.0 0.3 1.0 (mg/L) 0.3 0.1 1.0 (mg/L) (mg/L) 1.0 0.1 1.0 (mg/L) 0.3 0.3 0.3 (mg/L) 4.0 4.0 4.0 6.07.0 1 2 JIS K 0101 2 a b c 4.2 IDF100150F-W 4 2 IDX-OM-Z004 4 (3) 1 Y Y , Y Y (4) 3 2 (5) 1( 2 3 4 a) 1. 1.5 2. 4.2 IDF100150F-W
48 13.5 Electrical entry Grommet DIN terminal Conduit terminal Conduit Q R Q R S Q R S T Q R VXS23 1/4, 3/8 29.5 66 67 58 55 110.5 60 79.5 102.5 50 60 VXS24 1/2 29.5 69.5 67 61.5 55 110.5 63.5 79.5 109 50 63.5 VXS25 3/4 32 78 69.5 70 57.5 113 72 82 120.5 52.5 72 VXS26 1 32 81 69.5 72.5 57.5 113 74.5 82 126.5 52.5 74.5 Model Port size P 224 Zero Differential Pressure Type Pilot Operated 2
o32,a4ol51o IOC) o50 to 61 00/1 0 to 1 0O Singleacting Spring return/extend s 1 2 1 0 6 4 U 5 , 1 0 o50h0.20 Ion.rotating rod Double acting Singl rod o12, @16/5 lD 30 o20, @295to 50 o32, o4ol510 1OO o50, 0631 0 to 1 00 Double rod s12, s1615 lo 30 o20 lo o40l5 to 50 o50, a6310lo 50 @Actuation Doude acting Srngle acting spnng refurn Single acting sprinq extend Larg bore siro Double acting
The machine stops once after moving the distance set in Pr.50 "Setting for the movement amount after near-point dog ON" from the OFF --> ON position. Later the operation restarts and then stops at the first zero signal to complete the machine OPR.
) 10 (%) [mA] 40 NPN PNP NPN PNP 2 OUT1: OUT2: [mA] 80 [V] 28(NPN ) 26.4(NPN ) [V] 2 (80mA ) [ms] 2.5 (20,100,500,1000,2000ms ) 0.2 (%) F.S. 1digit 1 0 1 0 ( ) 1 to 5V2.5 (%) F.S. 1 (%) F.S. 1k 3 1/2 7 LED () 2 (%) F.S. 1digit (253) ON OUT1: OUT2: IP40 [] -5 to 50 -10 to 60 [%RH] ,35 to 85 [ACV] 1000 1 [M] 50 (DC500V ) 2 (%) F.S. (-5 to 50 25) 2 (AWG26) 5
=20mm 3263 =30mm 80 =50mm 0.5MPa MHSH3 / MHSH3-32DA MHSH3-40DA MHSH3-50DA MHSH3-63DA MHSH3-80DA mm 12 20 25 32 40 MPa 0.20.6 0.10.6 -1060 c.p.m. 60 30 mm 5 5 10 10 15 N 1 45 130 204 335 524 g 530 770 1,330 2,300 4,000 1) 0.5MPa MHSH3-32DB MHSH3-40DB MHSH3-50 DB MHSH3-63 DB MHSH3-80 DB mm 5 5 10 10 15 N 6~10 11~15 20~25 29~34 49~59 g 500 740 1,290 2,250 4,000 g 32 40 50 63 80 MHSHJ3
For ordering information, refer to the option part numbers on page 82. 74 3 Controller Series LC1 Performance/Specifications General specifications Model LC1-1H1 LC1-1H2 Item 100/110V AC 10%, 50/60Hz (100V AC, 50/60Hz for LC1-1HV1) 200/220V AC 10%, 50/60Hz (200V AC 10% for LC1-1H32) (200V AC, 50/60Hz for LC1-1HV2) Power supply Leakage current 5mA or less Dimensions 80 x 120 x 244mm Weight
Dynamic moment Me3 L2 We W = 1/3 14.7 (50 + 27) 103 Review Me3. = 0.38 [Nm] 3 = Me3/Me3 max = 0.38/3 = 0.13 Guide central axis A Me1 W We Me1 = 1/3 We (L1 + B) 103 = 1/3 14.7 (50 + 48) 103 L1 B = 0.48 [Nm] 4 = Me1 /Me1 max = 0.48/3 = 0.16 Review Me1.
Dynamic moment Me3 We W L2 = 1/3 14.7 (50 + 27) 103 Review Me3. = 0.38 [Nm] 3 = Me3/Me3 max = 0.38/3 = 0.13 Guide central axis A Me1 W We Me1 = 1/3 We (L1 + B) 103 = 1/3 14.7 (50 + 48) 103 L1 B = 0.48 [Nm] 4 = Me1 /Me1 max = 0.48/3 = 0.16 Review Me1.
Dynamic moment Me3 We W L2 = 1/3 14.7 (50 + 27) 103 Review Me3. = 0.38 [Nm] 3 = Me3/Me3 max = 0.38/3 = 0.13 Guide central axis A Me1 W We Me1 = 1/3 We (L1 + B) 103 = 1/3 14.7 (50 + 48) 103 L1 B = 0.48 [Nm] 4 = Me1 /Me1 max = 0.48/3 = 0.16 Review Me1.
, 63 CY1S, CY1L: 6 to 40 12, 16, 20 25, 32, 40 50, 63, 80 100 12, 16, 20 25, 32, 40 50, 63, 80 100 20, 25 32, 40 50, 63 32, 40 50, 63 80, 100 6, 10 16, 20 25, 32 10, 16 20 25, 32 12, 16 20, 25 32, 40 6, 10 15, 20 25, 32 6, 10 16 20, 25 32, 45 6, 10 16 20, 25, 32 40, 50 10, 15 25 12, 16 20, 25 Bore sizes (mm) 5 to 50mm/s 7 to 50 mm/s 5 to 50 mm/s 5 to 50mm/s Piston speed Shock absorber (optional
Solenoid valve ( ): Effective area [mm2] : Metal seal Speed controller Composed effective sectional area (mm2) B 9.0 to 14.4 A 3.6 to 6.3 VQ1000 (4.5) VQ1000 (6.3) SY3000 (5.9) SX3000 (5.9) VJ5000 (3.6) VZ3000 (3.6) C 16.2 to 18.0 D 36 to 45 VF5000 (45) E 64.8 to 67 Refer to System selection table, and the appropriate solenoid valve, speed control valve ad bore size may be selected.
Time Accumulated pulse output mode 50 msec Time -35No.LV50***-OMQ0002-G [F 2] Setting of OUT2 Set the output mode of OUT2.
CN1(P.18) 4.2 CN2CN3: LE-CP-CN3 CN2 4.3 CN4I/O 1 CN4 3m 16 - 2 USB 120.3 120.3 mm mm 200 200 mm/s mm/s USB A-miniB type 100 500 100 500 1 1 200 1000 200 1000 2 2 50 200 50 200 3 3 CN4 4.4 CN5I/O PLC I/O CN5 PLC 6.4 I/O P.27 6.3 /(P.24) 17 - 5.
, 3/8 VCW31 30 50 86 36.5 13.5 15 32 25 23 M5 8 24 59 46 57 60 54.5 48.5 101 57 68 104 1/2 22 45 90 41 11 17 36 22.5 23 M5 8 26 64.5 48 62.5 62 60 50.5 103 62.5 70 107 1/4, 3/8 VCW41 30 50 94 41 13.5 17 36 25 23 M5 8 26 66.5 48 64.5 62 62 50.5 103 64.5 70 111.5 1/2 35 60 102 41 17.5 17 36 30 28.2 M5 8 26 70 48 68 62 65.5 50.5 103 68 70 119 3/4 17-2-55 8 Series VCW Dimensions (N.O.)
VQ VKF Surge voltage suppressor mounting part (For G) VQZ VZ VS VFN Surge voltage suppressor Electrical entry G Grommet, 300 mm lead wire H Grommet, 600 mm lead wire C Conduit JIS Symbol T Conduit terminal D DIN terminal Rated voltage 50 60 1 2 3 100 VAC, Hz 200 VAC, Hz 110 VAC, Hz 220 VAC, Hz 50 60 50 60 4 50 60 5 6 24 VDC 12 VDC 7 240 VAC, Hz 50 60 9 Other Option Manifold Accessory