(SI unit side) Valve manifold Output No. 1 3 5 7 9 17 29 31 Solenoid on side B Accessories Bit No. 1 3 5 7 1 1 5 7 Replacement of the SI unit Remove the M3 hexagon screw from the SI unit and release the SI unit from the valve manifold. Replace the SI unit.
Round head screw (M3 x 8) , 4 pcs. EX600-ZMV2 (Specified for SY series) Enclosed parts: Round head screw (M4 x 6) , 2 pcs. Round head screw (M3 x 8) , 4 pcs. (2) End plate bracket EX600-ZMA2 Enclosed parts: Round head screw (M4 x 20) , 1 pc. P tight screw (4 x 14) , 2 pcs. EX600-ZMA3 (Specified for SY series) Enclosed parts: Round head screw (M4 x 20) with washer, 1 pc.
Withstand voltage -13No.PF-OMA1011-A Mounting and Installation Installation Mounting by panel mount adapter Fix the panel mount adapter to the Controller with the set screws M3 x 8L (2 pcs.) as attached.
0.5 ~0.6 Nm + G 1/2 M3 0.5 ~0.6 Nm M3 0.5 ~0.6 Nm A-A () 1) 2) 3) 30 1) 2) 1 0.1MPa 5 VN-OMP0002 Series Series Series Series 1 DC AC VT307 VNA ( ) (JIS B2301)(JIS B 2302) VNA (JIS B 6349) VNA 1 ISO VG32 VNA ( JIS K 6439) VNA VNA VNA VNA AS AS AS AS VNA AS 10A 111 420-03 3/8 B(9.5) 12 12 12 12(P1) (P1) (P1) (P1) 10(P2) 10(P2) 10(P2) 10(P2) 12(P1)10(P2) 15A 211 420-04 1/2 B
0.5 ~0.6 Nm + G 1/2 M3 0.5 ~0.6 Nm M3 0.5 ~0.6 Nm A-A () 6 VN-OMP0001 VNC VNC VNC VNC VNH VNH VNH VNH / / / / 1 DC AC VT307 12(P1) 12(P1) 12(P1) 12(P1) 10(P2) 10(P2) 10(P2) 10(P2) 12(P1)10(P2) Air operated Solenoid Port VNC02 12 (P1) External pilot Bleed port External pilot 10 (P2) Bleed port External pilot Pilot exhaust Ass Ass Ass Ass y y y y VNH VNH VNH VNH () 3 3 3 3
Speed controller with one-touch fittings , Body sizes: M3, M5, 1/8, 1/4, 3/8, 1/2 , Maximum operating pressure 1MPa, Meter in or meter out control , Port sizes: M3, M5, U10/32, 01, 02, 03, 04 , Various tube O.D. in both metric and inch, FLOW CONTROL W/FITTING *LQA, AIRLINE EQUIPMENT, AS***F 1/2INCHSTANDARD (NPT), .21958 lb
As the indicator LED protrudes from the switch unit, mounting the switch bracket above the LED may cause damage to it. (4) Insert the auto switch mounting screw (M3) included in accessories from the mounting hole of the auto switch mounting band, inserting the through hole of the switch bracket.
Nm N M1 M M3 W W2 W W4 ML2B25 10.0 1.2 3.0 200.0 58.0 65.0 100.0 ML2B32 20.0 2.4 6.0 300.0 80.0 96.0 150.0 ML2B40 40.0 4.8 12.0 500.0 106.0 140.0 250.0 ML2B25 ML2B32 ML2B40 J 0.43 0.68 1.21 18 ML2B/M1 ML2B/W1 ML2B/W1 0 0 0 Nm 0 0 0 N N 0 m/s m/s m/s ML2B/M2 ML2B/W2 ML2B/W2 N m N N m/s ML2B/M3 m/s m/s 20 ML2B/W3 ML2B/W3 10 Nm 5 3 2 1 N N m/s m/s m/s ML2B/W4 500 N 00 N
Description Note Material Bracket set 1 SFD-BR100 With 2 countersunk head screws (M3) IDK e AMG AFF SFD200-C Component Parts No. Description Note Material AM Element 1 PC, Polyolefin, PU o !
) M2 M3 M1 M2 1.25 1.68 Slide 12 3 0.53 0.70 Ball bushing 3.34 4.25 Slide 16 7 1.53 2.11 Ball bushing 11.4 17.1 Slide l l 20 12 5.60 7.28 Ball bushing Note) For the purpose of calculating the moment, the length of the arm is the distance that is measured from the guide shaft center ( mark).
Dimensions L A LA Attached from top W C PA MM Note 1) M F HB HA Note 2) Attached from bottom: MD R Body B (mm) Note 1) Note 2) B C F HA HB L LA MM MD M PA R W A Model CY3B15 CY3B20 CY3B25 CY3B32 CY3B40 16 35 6.5 5.5 16.5 23 57 25 M4 x 0.7 M3 4 25 6 36 18 36 6.5 5.5 17 23.5 66 30 M4 x 0.7 M3 4 27 6 37 20 46 8.0 5.5 21 28.5 70 30 M5 x 0.8 M4 5 36 7 47 22.5 60 9.5 6.0 27.5 36 80 35 M6 x 1.0
Compressed air 1.0MPa Fluid Max. operating pressure Min. operating pressure (1) 0.05MPa 1.5MPa Proof pressure Ambient and fluid temperature Filtration rating 5 to 60C 0.01m(95% particle size collection) Oil mist removal rate Max.0.1mg/m3 (ANR) (2) (At saturation of element oil, less than 0.01mg/m3(ANR){0.008ppm}) 2 years or when pressure drop reaches 0.1MPa Element life Note 1) With N.O.auto
Assembly is required. 7 Technical Data Pressure dew point Condensed water calculation Atmospheric pressure 45 Relative humidity 100% 40 0.1MPa Amount of water in air g /m3 35 80% 60% 0.2 40% 0.3 0.4 0.5 30 0.6 0.7 0.8 25 Amount of condensed water 20% 3 8 1.0 18.2 3.0 = 15.2g/m3 20 2 3 4 1.5 15 10 5 8 7 3.0 1 6 0 5 Intake air temperature C (atmospheric pressure) Air temperature (Pressure
CUX16-PS Proper tightening torque (Nm) (cylinder body) 10 16 20, 25 32 Hexagon socket head cap screw size (mm) M3 Bore size (mm) Rod seal 1 pc. CUX20-PS Gasket 1 pc. CUX25-PS 0.5410% Grease pack (10g) 1 pc. CUX32-PS M4 1.2310% Seals cannot be replaced for 10mm bore size. M5 2.5510% M6 4.0210% 2.
Remove pilot valve mounting screws (M3, 2 pcs.), rotate the pilot valve at 180 and then re-tighten the valve with the screw.
Real-time switch output Unit switching Hysteresis mode ON YES Accumulated flow l Display Real-time flow rate l/min OFF P-1 P-2 Real-time flow rate GPM gal (US) "P" Window comparator mode H : Hysteresis GPM = gal (US)/min H H Note) Fixed SI unit (l/min, l, m3 or m3x10) will be set for the type without the unit switching function.
Note Holding force N (Maximum static load) Equivalent to 0.5MPa Switch mounting screw (M3 x 0.5 x 10l) 32, 40 50, 63 80, 100 BQ-2 Standard Strokes Switch spacer Switch mounting nut Standard stroke (m) 5, 10, 15, 20, 25, 30, 35, 40, 45, 50 10, 15, 20, 25, 30, 35, 40, 45, 50, 75, 100 Bore size (mm) 20, 25 32, 40, 50, 63, 80, 100 Applicable switch Reed switch Solid state switch D-F7/J79 D-F7V
Dimensions L A LA Attached from top W C PA MM Note 1) M F HB HA Note 2) Attached from bottom: MD R Body B (mm) Note 1) Note 2) B C F HA HB L LA MM MD M PA R W A Model CY3B15 CY3B20 CY3B25 CY3B32 CY3B40 16 35 6.5 5.5 16.5 23 57 25 M4 x 0.7 M3 4 25 6 36 18 36 6.5 5.5 17 23.5 66 30 M4 x 0.7 M3 4 27 6 37 20 46 8.0 5.5 21 28.5 70 30 M5 x 0.8 M4 5 36 7 47 22.5 60 9.5 6.0 27.5 36 80 35 M6 x 1.0
Hexagon socket head cap screw Round head Phillips screw With spring washer, M3 x 0.5 x 14 L With spring washer, M3 x 0.5 x 16 L Switch mounting fitting Magnetic field resistant auto switch Mounting bracket kit number Items and number of each item Switch mounting bracket x 1 Switch mounting nut x 1 Round head Phillips screw x 1 Hexagon socket head cap screw x 2 Spring washer x 4 BQP1-
Assembly is required. 7 Technical Data Pressure dew point Condensed water calculation Atmospheric pressure 45 Relative humidity 100% 40 0.1MPa Amount of water in air g /m3 35 80% 60% 0.2 40% 0.3 0.4 0.5 30 0.6 0.7 0.8 25 Amount of condensed water 20% 3 8 1.0 18.2 3.0 = 15.2g/m3 20 2 3 4 1.5 15 10 5 8 7 3.0 1 6 0 5 Intake air temperature C (atmospheric pressure) Air temperature (Pressure