SMC Corporation of America
Elite Part Number Search
Search Results "SYJ5120-5WOU-N3-F-Q"

Bore size Standard stroke (mm) MM YY L X K W J V H GA GB TA TB U G T F S DA R C Z NN Q B ML P PW YL (mm) 12 16 20 25 18 50 13 5 16 40 58 5 7.5 5 36 29 56 8 22 6 48 29 12 14 39 7 10, 20, 30, 40, 50, 75, 100 M4 x 0.7 10 M4 x 0.7 M5 x 0.8 7 M4 x 0.7 11 22 54 15 7 18 42 64 2.5 8 5.5 38 33 62 8 25 8 52 33 13 16 43 8 10, 20, 30, 40, 50, 75, 100 M5 x 0.8 13 M5 x 0.8 M5 x 0.8 5 M5 x 0.8 11 20, 30

N) 1 N: Approx. 0. 102 kgf F Stroke (mm) Bore size (mm) Model 25 50 75 100 125 150 175 200 MGTM 140 151 162 176 193 212 178 204 63 MGTL 199 212 226 243 170 186 127 143 MGTM 199 213 228 246 267 291 221 250 80 MGTL 180 192 205 220 237 255 154 62 MGTM 271 288 307 328 353 382 321 356 100 F MGTL 242 257 274 292 313 335 153 114 8-24-5 6 Series MGT Construction o !

.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Mounting style Auto switch Basic style Front mounting flange style Nil Without auto switch (Built-in magnet) B F For the applicable auto switch model, refer to the table below.

Nil S n Bearing type Slide bearing Ball bushing bearing M L Mounting style Auto switch Basic style Front mounting flange style Nil Without auto switch (Built-in magnet) B F For the applicable auto switch model, refer to the table below.

Options J: With drain guide M Mounting Dimensions Model Port Size (Nominal size B) A G F E D C B S 1.6 2.0 2.0 2.3 2.3 3.2 3.2 4.5 4.5 R 4.5 5 5 5 5 9 9 10 12 Q 26 28 28 34 34 50 50 60 76 P 70 84 84 100 100 110 110 130 180 O 54 66 66 80 80 88 88 102 136 N 35 40 40 50 50 55 55 65 85 L 9 12 12 14 14 14 14 16 20 K 5 8 8 8 8 10 10 10 15 J 15 20 17 22 19 25 21 30 40 I 56 66 66 80 80 90 90 100

Option Option 1.12-12 Electronic Vacuum Regulator Series ITV209l Operating Principles Operating Principles Pressure display When the input signal increases, the vacuum pressure solenoid valve q turns ON, and the atmospheric pressure solenoid valve w turns OFF.

How to Find the Flow Rate (at air temperature of 20C) Subsonic flow when P1 + 0.1013 < 1.89 (P2 + 0.1013) Q = 226S P(P2 + 0.1013) Sonic flow when P1 +0.1013 1.89 (P2 + 0.1013) Q = 113S (P1 + 0.1013) Q: Air flow rate [l/min(ANR)] S: Effective area (mm) P: Pressure drop (P1-P2) [MPa] P1: Upstream pressure [MPa] P2: Downstream pressure [MPa] Maintenance Correction for different air temperatures

Q = m x C x (T0 Tt) it = r x V x C x iT it = 1 x 20 x 4.2 x 103 x 12 900 = 1120 [J/s] 1120 [W] Q = m x C x (T0 Tt) it x 860 = c x V x 60 x C x iT it x 860 Cooling capacity = Considering a safety factor of 20%, 1120 [W] x 1.2 = 1344 [W] = 1 x 20 x 60 x 1.0 x 103 x 12 Thermo-chiller Q x t: Heat capacity [kJ] 15 x 860 1120 [W] 20C Water bath Cooling capacity = Considering a safety factor

E 2 x H A B C D Side support B MY-SB 2 x J A B C D A 61 70 87 B 75 84 105 C D E F G H J Part no.

applicable auto switch list. 909 Rotary Table MSQ 1122Specifications Suction Flow Rate of Vacuum Suction Type (Reference values) Size 1 2 3 7 10 20 30 50 Fluid Air (Non-lube) Size Suction flow rate L/min (ANR) 1/2/3/7 10/20/30/50 Air Preparation Equipment Pressure Control Equipment Flow Control Equipment Pressure Switches/ Pressure Sensors Directional Control Valves Air Grippers Modular F.

2 q u o e w !0 i t r !1 y With external stopper: CRJU !3 !8 !4 !5 !8 !7 !6 Component Parts Material Description Material Magnet Round head no. 0 Philips screw Hexagon socket head set screw Stopper Holder Stopper retainer Hexagon socket head set screw Hexagon nut Hexagon socket head cap screw Description No. !0 !1 !2 !3 !4 !5 !6 !7 !

2 q u o e w !0 i t r !1 y Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com With external stopper: CRJU !3 !8 !4 !5 !8 !7 !

0 Steel wire NBR Steel wire NBR XT010-20 XT010-21 XT041-1 4-16-6 3 Series VS3135/3145 Dimensions VS3135/3145 V100 SY SYJ VK VZ Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com VT 3-Port size VP 4-Q Mounting hole 3-Q Mounting hole VG VP S070 VQ VS3135 VKF VQZ VZ Q Terminal

types of mounting are possible Knock pin holes provided on each mounting surface make positioning easy 34 35 38 40 50 63 Top mount Side mount (1in = 25.4mm) A Body length Application examples Drop prevention for a upward facing cylinder Holding a clamped condition Retraction is locked Retraction is locked T-slot side mount Bottom mount LOCK LOCK Series MLGP How to Order MLGP M Z73 40 50 F

Reference formulas [Dynamic moment at impact] Use the following formulas to calculate dynamic moment when taking stopper impact into consideration. m F FE a M 1.4 = 1.4a (mm/s) FE = agm Note 4) 100 1 ME = FE L = 0.05a m L (Nm) Note 5) L ME g : Load mass (kg) : Load (N) : Load equivalent to impact (at impact with stopper) (N) : Average speed (mm/s) : Static moment (Nm) : Impact speed

3 i w u o y q Section B-B' (Solenoid valve) Component Parts Replacement Parts Note Description Material Description Part no. No. No. SY114Urban white Resin Manifold block 3 port solenoid valve q o ZSE1-00--X130 Urban white Zinc die-casted Body Vacuum switch w !0 Urban white Resin Silencer cover P44027A End plate assembly e !1 Aluminum Nozzle AN203-KM8 Silencer r !

Fit the grooved part of gasket w into the flange part of case q. b. Place element e in case q. Element e must be positioned at the center of case q. c. Set clamp ring t to case q. The tapered part of clamp ring t must be facing downward. d. Set seal part of the element e to the cover r while the flange part of case q is being placed on clamp ring t. e.

Fit the grooved part of gasket w into the flange part of case q. b. Place element e in case q. Element e must be positioned at the center of case q. c. Set clamp ring t to case q. The tapered part of clamp ring t must be facing downward. d. Set seal part of the element e to the cover r while the flange part of case q is being placed on clamp ring t. e.

[F 2] 2 Press the button once to reduce the value by one digit, press and hold to continuously reduce. : Display set by customer [F 3] [FiL ] Select digital filter [ 1.0] 1 second Product number Suitable screws Tightening torque Thread depth [F 5] [FUnC] Select FUNC (switching analogue output 3/external input) [AoUt] Analogue output Align the master IO-Link version to the device.

Stainless steel 9 With switch only Magnet plate Aluminum alloy 10 With switch only Switch mounting bracket 11 Scraper 12 With back-up ring Rod seal NBR 13 Piston seal 14 Tube gasket 15 Piston gasket 18 Series CHKGB Dimensions 2-Rc P F with effective thread depth G Q S Width across flats f c R D R a b g e H E C B + Stroke h + Stroke 4-K through J 8-L counter bore A + Stroke M Rod end male