6 Body size If more than one option is required, write option part numbers in the order of K, N. 1 2 3 4 M5 standard 01, 02 standard 03 standard 04 standard Tube size (1) 4 6 8 10 12 04 06 08 10 12 Electroless nickel plated (3) Brass PBT PBT/Stainless steel NBR NBR NBR NBR NBR NBR NBR/Stainless steel Electroless nickel plated Elbow type Control method Meter-out Meter-in 0 With One-touch fitting
AS431F-04 R 1/2 Note 1) Elbow type only Note 2) Meter-out and meter-in types can be visually differentiated by the lock nut.
(mm)Connection threadsModel Elbow typeUniversal type Meter-outMeter-inMeter-outMeter-in12R 1/2AS4201FG-04-12AS4211FG-04-12AS4301FG-04-12AS4311FG-04-12
Without auto switch 4, 6, 8, 10 Bore size (mm) M3 x 0.5 6 Port size Stroke (mm) 8 or more AS121F-M3-23 AS121F-M3-04 AS131F-M3-23 AS131F-M3-04 Note) Only applicable to the mounting position shown in Figure 1 below. Figure 1 Mounting position 1 Mounting position 2 a) Side mount b) Front mount Mounting position 3 Mounting position 4 Notes) 1.
Model L5 D3 T2 13.7 18.7 16.8 18.7 18.7 20.8 20.8 21.8 34.6 33.9 11.8 39.6 38.9 22.9 28.2 25.2 28.2 28.2 32.6 32.6 34.4 11.6 15.2 12.8 15.2 15.2 18.5 18.5 20.9 38.4 44.7 43.4 46.4 51.3 54.1 64.2 66 14 15.8 18 19.7 20.3 23.1 32 35 65 68 107 110 212 215 6 8 6 8 8 10 10 12 ASP330F-01-06S ASP330F-01-08S ASP430F-02-06S ASP430F-02-08S ASP530F-03-08S ASP530F-03-10S ASP630F-04-10S ASP630F-04-12S
One-touch fitting ARJ310-01 ARJ310-N01 ARJ310F-01-04 ARJ310F-01-06 ARJ310F-N01-03 ARJ310F-N01-07 R 1/8, M5 x 0.8 NPT 1/8, M5 x 0.8 R 1/8, M5 x 0.8 NPT 1/8, M5 x 0.8 Note) M5 x 0.8 female thread is cut inside the pipe.
06 10 1/4 3/8 1/2 3/4 1 Applicable model AMR3l00-02 to 03 AMR4l00-02 to 04 AMR5l00-04 to 06 AMR6l00-10 R 3 4 5 6 Body size 3 4 5 6 Adapter ass'y port size (2 pcs.)
420-04-F 121F-M3 131F-M3 121F-M5 (U10, 32) 131F-M5 (U10, 32) 221F-01 231F-01 2211F-01-06 221F-02 231F-02 321F-03 (02) 331F-03 (02) 421F-04 431F-04 1000F 2000F 2050F 3000F 4000F 1001F 2001F 2051F 3001F 4001F 230F 330F 430F 530F 630F 330F 430F 530F 630F Manifold regulator 4-, 5-port solenoid valve VQ Directional control valves 0 1000 2000 4000 5000 1000 2000 3000 1000 2000 1000 3000 5000 7000
1 3 Port Air Operated Valve Series VGA342 How to Order SA 04 VGA342 A VA Port size Passage A Normally closed (N.C.) B Normally open (N.O.) Thread type Nil Rc F G N NPT T NPTF 04 1/2 06 3/4 10 1 SA VA JIS Symbol VM N.C. N.O.
02 12 02 04 02 9 stations 4 stations 12 stations 4 stations 2 stations 2 stations 2 stations 2 stations (2) (2) (2) (2) Specified layout (Up to 8 solenoids possible.)
JIS Symbol How to Order VR 12 1 06 0 F Body size Applicable tubing diameter Metric size Inch size 1 2 1/8 standard 1/4 standard 23 04 06 08 10 3.2 01 03 07 09 11 1/8" 5/32" 1/4" 5/16" 3/8" 4 6 8 10 Shuttle valve With One-touch fittings For 3.2, use 1/8" tubing. 5-7-5 63 Series VR1210F/1220F Example of Operating Circuit OR circuit Self-hold circuit Interlock circuit When either A or B is
One-touch fitting ARJ310-01 ARJ310-N01 ARJ310F-01-04 ARJ310F-01-06 ARJ310F-N01-03 ARJ310F-N01-07 R 1/8, M5 x 0.8 NPT 1/8, M5 x 0.8 R 1/8, M5 x 0.8 NPT 1/8, M5 x 0.8 Note) M5 x 0.8 female thread is cut inside the pipe.
RCSK-o15 RCSK-02 RCSK-03 RCSK-04 BCSK-05 RCSK-O5 RCSK-08 RCSK-10 Double Hod clevi6 w/ oin(1). retainina rinos{2) RCDK-015RCDK.02 RCDK{3 RCDK-04 RCDK.OS RCDK.05 RCDK-08 RCDK.lO 'Jah nul sold separatly 'For accessory parl dimensions see cat.
For Water Digital Flow Switch Series PFW How to order PFW7 20 03 27 Integrated display type Flow rate range 0.5 to 4l/min 2 to 16l/min 5 to 40l/min 04 20 40 Unit specification Thread type Nil M With unit switching function Fixed SI unit Note) Rc NPT G Nil N F Wiring specification Note) Fixed units: Real-time flow rate: l/min Accumulated flow: l 3m lead wire with connector Without lead wire
How to Order VR 12 1 06 0 F Body size Applicable tubing outside diameter Metric sizes Inch sizes 1 2 1/8 standard 1/4 standard 23 04 06 08 10 01 03 07 09 11 3.2 4 6 8 10 1/8" 5/32" 1/4" 5/16" 3/8" With One-touch fitting Use 1/8" tubing for 3.2. 1 Series VR120F Application Circuit Examples Self holding circuit 1. When "A" is turned ON, output goes ON. 2.
x 0.8 5 9 ZPT32F-B8 32 35 M8 x 1.25 8 12 13 16 36.5 ZPT32F-B01 Rc(PT)1/8 6.2 14 Width across flats P N NL F D C Y 2.5 A B Dimensions A (mm) B C D F N NL P Y Model ZPT40F-B8 M8 x 1.25 8 12 40 43 12.5 18.5 39 5 ZPT40F-B01 Rc(PT)1/8 6.2 14 ZPT50F-B8 M8 x 1.25 8 12 50 53 13.5 19.5 40 6 ZPT50F-B01 Rc(PT)1/8 6.2 14 4 Vertical Vacuum Entry Series ZPT With Buffer How to Order ZPT 10 F GN J 20 04
04 C2 2 H 02 2 C4 4 L 04 4 N1 1/8" 01 1/8" N3 5/32" 03 5/32" L2 2 4 L4 4 LN1 1/8" LN3 5/32" -N KJL04-C1-N 10 Assy ZB1-FE3-A 30m ZA ** 10 1 0-101kPa15V 2%F.S ZA ZB1-SE1-A 3 -100100kPa15V 2%F.S.
(.) 8-2 Ball valve Heavy duty auto drain (ADH4000-04) (10) Drain tube IDU Series 8-1 8 1 IDX-OM-W029 8 L 8-3 (ADH4000-04) IDU22E75E-23/30-L N.O() ) 0.151.6MPa ) 50L/min (ANR) 8-4 IDU Series 8-3 (ADH4000-04) 8 2 IDX-OM-W029 9.M 9 9-1 ( ) 9-2 ADM200 IDU22E/37E-30-M IDU55E/75E-30-M ADM200-042 ADM200-042-4 (IDF-S0090) (IDF-S0510) 1.0MPa 1 1 1 2 2 / AC200V(50/60Hz)
(.) 9-2 Ball valve Heavy duty auto drain (ADH4000-04) Drain tube (10) IDFA Series 9-1 9 1 IDX-OM-W032 9 L 9-3 (ADH4000-04) IDFA22E 75E-23-L ) 0.151.6MPa N.O.() 3/h(ANR) ) 3m 9-4 1.
02 03 04 04 06 10 10 12 01 02 01 02 14 20 VEX312VEX322VEX332VEX342VEX350VEX370VEX390( ) VEX1-18-1A VEX5-32A VEX7-32A VEX9-32A ( ) VEX1-18-2A VEX3-32-2A P2 AN120-M5 AN103-01 AN210-02 1) VEX1-9-1P VEX4-2A-P VEX1-11-2 VEX4-4 DXT152-14-1A NXT013-3 VO307K-1 2) 3) VEX322 VEX342 Rc A 1/8 1/4 F G VVEX2 VVEX4 B 1/4 3/8 N NPT ( ) VEX1-17 VEX4-5 C 1/2 T NPTF 11 No.VEX-OMY0001 (2) () 3 2(A