Effective area (mm) Weight g A
Positioning Time Guide Positioning time A: Acceleration time B: Constant velocity time C: Deceleration time D: Resting time (0.4sec.)
Operating vacuum pressure 100 kPa Proof pressure 3.0 MPa Ambient and fluid temperature 5 to 60C (No freezing) Mounting section JIS B 0203 (Taper thread for piping) Thread JIS B 0209 Class 2 (Metric coarse thraed) Nut section JIS B 0211 Class 2 (Metric fine thread) Sealant (Male thread) With thread seal Copper-free (Standard) Brass parts are all electroless nickel plated Principal Parts Material
Applicable bore size (mm) A1 L NDd9 MM B C d H B C d H 0.030 0.060 0.030 0.060 Y-J010SUS 10 SNJ-016SUS 10 NTJ-010SUS 10 3.3 14 7 8 15.2 21 M4 x 0.7 16.2 M10 x 1.0 4 8.1 M4 x 0.7 3.2 Y-J016SUS SNKJ-016SUS NTJ-015SUS 16 16 16 5 17 8 11 16.6 21 M5 x 0.8 19.6 M12 x 1.0 4 9.2 M5 x 0.8 4 NDH10 U1 NX R1 Part no. +0.048 0 Y-J010SUS 3.3 3.2 8 10 +0.048 0 Y-J016SUS 5 6.5 12 10 Rod end cap T-bracket
stroke of 25 mm or less RZQ MI W S B A CEP1 CE1 CE2 [mm] Proper Mounting Position D-A7H,A80H D-A73C,A80C D-F7,J79,J79W D-F7V,J79C D-F7W,F7WV D-F7BAL,F7BAVL D-F79F ML2B D-M9 D-M9V D-F9W D-F9WV D-A79W D-A9 D-A9V C J G5-S D-A7,A80 D-F9BAL D-P5DWL Bore size (mm) CV B A B A B A B A B A B A B A MVGQ 32 27 37.5 27.5 38 24.5 35 26 36.5 30 40.5 29 39.5 40 CC 27 39 31 43 31.5 43.5 28.5 40.5 30 42
Hs A B A B 32 to 100 D-A73C D-A80C D-J79C D-A79W D-F7V D-F7WV D-F7BAVL Approx.
Auto switch mounting surface Bore size (mm) 20, 25 63, 80, 100 32, 40, 50 Port side Port side Port side C A C A C A B B B Auto switch mounting surface Auto switch mounting surface Auto switch mounting surface Auto switch model Port side A, B, C sides A, B, C sides Port, A, B, C sides BQ-2 BQ2-012 Two kinds of auto switch mounting brackets are used as a set.
A B A B 54 MXY6 34 MXH 59 5 MXY8 39 MXU 67 MXY12 47 MXS Solid State Auto Switch D-M9B(V), D-M9N(V), D-M9P(V) Lead wire entries inside MXQ (mm) B B Model Mounting Auto switch operating range MXF A B A B A B 50 MXY6 3 38 MXW 55 MXY8 3.5 43 MXJ 63 MXY12 3 51 MXP Lead wire entries parallel 2-Color Display Solid State Auto Switch D-M9BW(V), D-M9NW(V), D-M9PW MXY (mm) B A Model Mounting Auto switch
stroke 50 or larger bore size D-P5DW 40, 50, 63 B + First-stage stroke =U =U Mounted on different side in case of a full stroke of 25 mm or less B A [mm] Proper mounting position D-A7H,A80H D-A73C,A80C D-F7,J79,J79W D-F7V,J79C D-F7W,F7WV D-F7BAL,F7BAVL D-F79F D-F9 D-F9V D-F9W D-F9WV D-A79W D-F7LF D-A9 D-A9V D-F9BAL D-P5DWL D-A7,A80 Bore size (mm) A B A B A B A B A B A B A B A B 32 29 39.5
,oox'o''"n' ar3oro 60 Nole 2) Drain guide is G1i 4 (app cable 10 AF30lo 60) Nore 1) Wlhoul a valve name plate and caulion A F 1 0 1 0 6 0 Port size Symbol Port 1 0 20 30 40 50 60 Symbol Descrlption Applicable M5 a 1 B O AF20 to 60 1t4 a a a 3a a a 1t2 a g4 a a 1 a a auto dlain (N C.)
(inch) Thread UNF NPT UNF, M5, M6 10-32 UNF, M5, M6 Weight (g) H (Hex.)
AF-OMQ0004-C PRODUCT NAME AIR FILTER MODEL / Series / Product Number AF10-M5(C)(-2,6,R,Z)-A AF20-(F,N)01(F,N)02(B,C)(-2,6,C,J,R,Z)-A AF30-(F,N)02(F,N)03(B,C,D)(-2,6,8,J,R,W,Z)-A AF40-(F,N)02(F,N)04(B,C,D)(-2,6,8,J,R,W,Z)-A AF40-(F,N)06(B,C,D)(-2,6,8,J,R,W,Z)-A AF50-(F,N)06(F,N)10(B)(-2,6,8,J,R,W,Z)-A AF60-(F,N)10(B)(-2,6,8,J,R,W,Z)-A Contents Page 1. SAFETY INSTRUCTIONS 1-5 2.
B 0.2 A 0.2 Bore size A [mm] B [mm] Hexagon socket head cap screw 12 (10 x 2) 52 11 M3 x 0.5 16 (12 x 2) 57 11 M4 x 0.7 20 (16 x 2) 75 14 M4 x 0.7 25 (20 x 2) 84 17 M5 x 0.8 32 (25 x 2) 98 21 M6 x 1.0 40 (32 x 2) 107 27 M8 x 1.25 50 (40 x 2) 135 37 M8 x 1.25 63 (45 x 2) 146 40 M10 x 1.5 80 (56 x 2) 184 50 M12 x 1.75 100 (71 x 2) 219 62 M14 x 2 8.
Applicable blank plate assenbly SY100-77-1A VZ P R 20 stations 20 R port VS A port M5 X 0.8 P port M3 X 0.5 M5 X 0.8 M5 X 0.8 Note 1) SY114 (A) and SY124 (A) cannot be mounted on the same manifold.
D(Finger closing port) M5 x 0.8 (Finger closing port) M5 x 0.8 20Auto switch mounting groove (4 locations) 4-M6 x 1 (Piston rod and rack screw) Width across flats 10 (4 locations) Closed E 4-M5 x 0.8 through Open F (Thread for mounting attachment) (mm) A B C D E F G H 40 70 90 J 98 152 192 Model MHL2-16D MHL2-16D1 MHL2-16D2 45 75 95 60 90 110 28 58 78 68 110 130 98 170 210 128 200 240 26
Power supply 24 VDC B B B Ground with a ground resistance of 100 or less without connecting the DC1 () lead (Blue) of the power supply cable to the power supply 0 V. Red A A +24 V Black Blue Charged object Charged object 0 V Reduced-wiring Fieldbus System F.G. (mm) Ground with a ground resistance of 100 or less. A B When using the autobalance sensor (body-mounting type) 10 20 20 40 3.
The values of Av and Cv are based on JIS B 2005:1995, C and b are based on JIB B 8390:2000.
Tap M5 thread on the brackets mounting positions at the installation side, and fix the ionizer body and brackets with M5 threads. M5 tap M5 threads 4. Adjust angle of the ionizer body to ensure proper static charge elimination, and fix it with detent threads (M5) of brackets.
Description Material 32 PDU-12LZ 40 NBR 20 PDU-8Z 25 Rod seal PDU-10Z PDU-14LZ #4 How to order solenoid valves VZ319Voltage Electrical entry 10-15-35 Series CVM3 Basic Style (B) Single acting, Spring return: CVM3B S Bore size Stroke M5 x 0.8 Width across flats B2 Manual override Width across flats B1 S + Stroke ZZ + Stroke Single acting, Spring extend: CVM3B T Bore size Stroke H + Stroke