SMC Corporation of America
Elite Part Number Search
Search Results "ZSE20B-L-M-N01-S"

Flow Rate Range: 25 [0.5 to 25 (25 for CO2) ℓ/min], Flow Adjustment Valve: Yes, Port Size: NPT1/8, Piping Entry Direction: Straight, Output Specification: E [1 PNP Outputs + Analog (1 to 5 V)], Unit Specification: Fixed SI Unit, Instruction Manual: With Instruction Manual, Calibration Certificate: None, Connector: Lead Wire w/Connector (2 m), Option: Bracket for w/Flow Adjustment Valve

Flow Rate Range: 10 [0.2 to 10 (5 for CO2) ℓ/min], Flow Adjustment Valve: Yes, Port Size: NPT1/8, Piping Entry Direction: Straight, Output Specification: E [1 PNP Outputs + Analog (1 to 5 V)], Unit Specification: Fixed SI Unit, Instruction Manual: With Instruction Manual, Calibration Certificate: None, Connector: Lead Wire w/Connector (2 m), Option: Bracket for w/Flow Adjustment Valve

Flow Rate Range: 50 [1 to 50 (25 for CO2) ℓ/min], Flow Adjustment Valve: Yes, Port Size: NPT1/8, Piping Entry Direction: Straight, Output Specification: E [1 PNP Outputs + Analog (1 to 5 V)], Unit Specification: Fixed SI Unit, Instruction Manual: With Instruction Manual, Calibration Certificate: None, Connector: Lead Wire w/Connector (2 m), Option: Bracket for w/Flow Adjustment Valve

Flow Rate Range: 10 [0.2 to 10 (5 for CO2) ℓ/min], Flow Adjustment Valve: Yes, Port Size: NPT1/8, Piping Entry Direction: Straight, Output Specification: 2 NPN Outputs, Unit Specification: Fixed SI Unit, Instruction Manual: With Instruction Manual, Calibration Certificate: None, Connector: Lead Wire w/Connector (2 m), Option: Bracket for w/Flow Adjustment Valve

Output Specification: NPN Open Collector 2 Outputs + Analog Current Output, Unit Specification: SI Unit Only, Piping Specification: NPT 1/8, Lead Wire: w/o Lead Wire, Bracket: Panel Mount Adapter, Operation Manual: -

Output Specification: NPN Open Collector 2 Outputs + Analog Current Output, Unit Specification: SI Unit Only, Piping Specification: NPT 1/8, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Bracket: Bracket B, Horizontal Mounting, Operation Manual: w/o Operation Manual, Calibration Certificate

Output Specification: NPN Open Collector 2 Outputs + Analog Current Output, Unit Specification: SI Unit Only, Piping Specification: NPT 1/8, Lead Wire: w/o Lead Wire, Bracket: Bracket A, Vertical Mounting, Operation Manual: -

Piping: NPT1/8, w/M5 Female Thread, Output Specification: NPN Open Collector 2 Outputs+Analog Current/Auto-shift Switching, Unit Specification: Fixed SI Unit; for Vacuum/Compound Pressure: kPa; for Positive Pressure: MPa, Option: None, Calibration Certificate: None, Lead Wire: 3m

The ISE2 series is a compact, pressure switch (for positive pressure) and can be integrated with ZX or ZR vacuum systems. The ISE2 series pressure switch has a quick response time of 10mS and the plug connector option makes wiring easy and simple. 3 SCREEN HI PRECISION DIG PRESS SWITCH. N59. 73.00000 lb. PRESSURE SWITCH, ISE1-6.

P O R T S PT Ports XC18 NPT Ports (25~40 Only) A L L O W A B L E M O M E N T A N D M A X I M U M A L L O W A B L E L O A D H O W T O O R D E R M Y 1 M R O D L E S S C Y L I N D E R MY1M G M O M E N T (N M) A L L O W A B L E L O A D (N) B O R E S I Z E 16 16mm 20 20mm 25 25mm 32 32mm 40 40mm 50 50mm 63 63mm Local Production Available N O O F S W I T C H E S ...2 Pieces S ...1 Piece

Thread type Symbol Type Nil N F Rc NPT G 50 60 75 Port size 100 30 Port size Symbol Nil H L L S L S L S Nil H L 02 03 04 1/4 3/8 1/2 50 60 75 Components 100 30 Components Nil H L L S L S L S Nil H L Mist separator Micro mist separator Differential pressure gauge Regulator AFM40-A AFD40-A GD40-2-01-X29 AR40 Replacement Parts (Element for mist separator, micro mist separator) Description AFM40

L D-A73 (Example) 20Lead wire length Data 5 m None Nil L 0.5 m 3 m Z N Applicable for the connector type (D-C) only.

: Transfer load (kg) a : Work piece acceleration (mm/s) Me: Dynamic moment L : Overhang to work piece center of gravity (mm) m a = 2000 1000 L1 a = 3000 0 2 4 6 8 10 Transfer load m (kg) 600 L2 400 Mer L2 (mm) Rolling Yawing m 200 L2 Mer 0 2 4 6 8 10 m Transfer load m (kg) 3000 a = 1000 L3 (mm) 2000 L3 1000 a = 2000 m a = 3000 Mey a 0 2 4 6 8 10 Transfer load m (kg) Refer to page 145 for

weight m (kg) Load weight m (kg) 10 10 40 40 5 5 32 32 1 10 50 100 200 1 10 50 100 200 Eccentric distance l (mm) Eccentric distance l (mm) MGPL80, 100 (14) V = 400 mm/s 200 100 100 Load weight m (kg) 80 50 10 10 50 100 200 Eccentric distance l (mm) 8-19-31 Series MGP Horizontal Mounting (Slide bearing) MGPM16 to 100 (15) l = 50 mm, V = 200 mm/s (16) l = 100 mm, V = 200 mm/s 100 50 50 80

3 4 5 5 6 7 l\caut ion l n s t a l l a t i o n l n s t a l l a t , I D G s * M ( V ) i o n . r o n i n l e t s i d e 0 f m e m b l a n e a i r J i u t t , s u r e l v i n s t a l l m i s t s e p a r a t 0 r a n d m i c r o m i s t s e P a r a t o r ' t w i f n o u t t t r e m , i t d 0 e s n o t p e r f o r m ' w e l l b e c a u s e v a t e r a n d o i l f l o w i n ' l t F I u s h P j P

: Transfer load (kg) a : Work piece acceleration (mm/s) Me: Dynamic moment L : Overhang to work piece center of gravity (mm) m a = 2000 1000 L1 a = 3000 0 2 4 6 8 10 Transfer load m (kg) 600 L2 400 L2 (mm) Mer Rolling Yawing m 200 L2 Mer 0 2 4 6 8 10 m Transfer load m (kg) 3000 a = 1000 L3 (mm) 2000 L3 1000 a = 2000 m a = 3000 Mey a 0 2 4 6 8 10 Transfer load m (kg) Refer to page 145 for

Refer to page 336 for the lead wire length of L and M plug connectors. Refer to page 337 for the connector assembly with cover for L and M plug connectors. Note) Enter the cable length symbols in .

Reference formulae [Dynamic moment at impact] Use the following formulae to calculate dynamic moment when taking stopper impact into consideration. m F FE a M 1.4 = 1.4a (mm/s) FE = agm 100 1 ME = FE L = 0.05a m L (Nm) 3 L ME g : Impact speed (mm/s) : Distance to the loads center of gravity (m) : Dynamic moment (Nm) : Gravitational acceleration (9.8m/s) : Load mass (kg) : Load (N) :

L1: Use the graph to find the L when the speed is 300 mm/s and load mass is m = 0.3 kg. L = 30 mm / L1 max. overhang = 30 mm L2: Use the graph to find the L when the speed is 300 mm/s and load mass is m = 0.3 kg and multiply it by 1/2. L = 30 mm / L2 max. overhang = 30 mm/2 = 15 mm * For end plate mounting, L2 is 1/2 of the L which is found from the graph.