The element retainer shall be assembled in such a way that the symbol A-A in (a) of Fig. 6 is overlapped with symbol B-B of element retainer shown in (b) of Fig. 6 in parallel. B A B A C View of c Actuators Modular F.R.L.
The element retainer shall be assembled in such a way that the symbol A-A in (a) of Fig. 6 is overlapped with symbol B-B of element retainer shown in (b) of Fig. 6 in parallel. B A B A C View of c Actuators Modular F.R.L.
P2 [MPa] 0.75P1 0.75P1-0.012m 0.75P1-0.0078m 0.75P1-0.0050m 0.75P1-0.0031m 1.5P1-0.024m 1.5P1-0.016m 1.5P1-0.010m 1.5P1-0.0063m Bore size (mm) 32 40 50 63 32 40 50 63 Orientation Circuit Horizontal A Graph 3 10 Line Circuit Orientation Movement Down A r e Extension 2 3 4 5 A Horizontal e r Retraction e Extension A Down Overrun (mm) e Retraction Up C w q Extension 1 B Up e Retraction q P1
Air dryer model IDF100FS-30-R IDF125FS-30-R IDF150FS-30-R Breaker capacity 20 A 30 A Sensitivity current: 30 mA Corrosion is not covered under warranty. Option symbol V With a timer controlled solenoid valve type auto drain Option symbol Float type heavy duty auto drain is changed to the solenoid valve type auto drain.
The material consists of a good chemical resistant fluoropolymer. This also has good heat resistance, and it is suitable for a wide range of applications.
Note 2) Intermediate strokes are available as a special order. Data L R S Piping Port Locaition Nil Operating direction Left Right L R S a b h g d c f e Note) Plugs are installed in ports other than those indicated for the model. Applicable Auto Switch/Refer to page 8-30-1 for further information on auto switches.
Barrel Perfluoro R is a registered trademark of MATSUMURA OIL Co.,Ltd. Kalrez R is a registered trademark of E. I. du Pont de Nemours and Company. Chemraz R is a registered trademark of Greene, Tweed & Co., ULTIC ARMOR R is a registered trademark of NIPPON VALQUA INDUSTRIES, LTD.
2%4$2$4$5 @4 #0 Section A-A' 20A Data A' $0 $1 #4 #5 #2 @1 $6 $3 Component Parts No. Description Cam follower cap Magnet Magnet Seal magnet Rail End spacer Square nut Square nut Spring pin Parallel pin No.
Position of rotation axis: Parallel to side b and passes a center of gravity. 1=m 12 a 2 1=m 4 r 2 oWith a load at the lever end rThin rectangle board (Parallelogram) Position of rotation axis: Perpendicular to the board and passes through center line. 2 1 2 2 a +K 1=m1 +m2 3 a Ex.)
Do not use a stopper cylinder for intermediate stopping of loads directly connected to a cylinder, etc. The operating ranges shown in the catalog should only be used for stopping pallets on a conveyor. If loads connected directly to a cylinder, etc., are stopped with a stopper cylinder, the cylinder's thrust will become a lateral load. Please consult with SMC in this case. Danger 1.
Do not use a stopper cylinder for intermediate stopping of loads directly connected to a cylinder, etc. The operating ranges shown in the catalog should only be used for stopping pallets on a conveyor. If loads connected directly to a cylinder, etc., are stopped with a stopper cylinder, the cylinder's thrust will become a lateral load. Please consult with SMC in this case. Danger 1.
/ Construction 9 5 bn bn 4 8 1 3 2 bs A A' bl bq br bm bt bo bp bk 7 View A-A' 6 Material Note Parts list Material Note Parts list No.
Caution indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury. Caution: Warning indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury. Warning: Danger : Danger indicates a hazard with a high level of risk which, if not avoided, will result in death or serious injury.
Changing the entry direction The cable entry direction of a connector can be changed as desired (4 directions at 90 intervals), depending on the combination of a housing r and a terminal block e. 1.
Caution indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury. Caution: Warning indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury. Warning: Danger : Danger indicates a hazard with a high level of risk which, if not avoided, will result in death or serious injury.
1/8 1/4 F G VVEX2 VVEX4 B 1/4 3/8 N NPT ( ) VEX1-17 VEX4-5 C 1/2 T NPTF 11 No.VEX-OMY0001 (2) () 3 2(A) 23(P2) 12(P1) a,b 12(P1),23(P2) (2) a 12(P1) 1(P)2(A)3 3(R) 3(R) b 23(P2) 2(A) 2(A)3(R)1 1(P) 1(P) 12(P1) 1 2 3 23(P2) 4 5 6 7 8 POM 9 -12No.VEX-OMY0001 () () 3(R) 2(A) 1(P) 1(P) 2(A) 3(R) () a b P1P2 2(A) 1(P) -13No.VEX-OMY0001 (7) (1) (2) (3) (4) (5
Fittings & Tubing Air Cylinders Rotary Actuators Bracket (Option) Bracket (Option) R R V Q V Q IN OUT B C IN OUT Clearance for maintenance G B C 2 x P (Port size) 2 x P (Port size) Hexagon width across flats 14 1/8 Drain Hexagon width across flats 17 1/4 E A Clearance for maintenance G Drain A AF50/60-A 1021J D M U S N T Bracket (Option) R V Q C B IN OUT 2 x P (Port size) Hexagon width across