TUBE B85 = NYLON 1/8" I.D. TUBE P80 = POLYSULFONE 1/16" P85 = POLYSULFONE 1/8" 700 = N.O. 701 = N.C. 5 15 30 60 100 *For details of all available mounting styles see F-4200 series pressure switch. Back to Top . I Introduction Table of Contents Vacuum Series The 700 series is a pilot actuated pressure valve with a precision adjustable pilot setpoint.
Note) Port size A B D E30003-A 3/8 31.8 30 30 E40004-A 1/2 31.8 36 36 Seal A (Spacer width) Note) in part numbers indicates a pipe thread type. No indication is necessary for Rc; however, indicate N for NPT, and F for G. Separate interfaces are required for modular unit. Part no.
A B FD FT FV FX FV MI W S 10 10 to 40 49.5 31.5 4.5 5.5 30 45 FX FT L B + Stroke 16 10 to 60 54 34 6.6 8 39 48 FZ CEP1 20 10 to 60 57.5 37.5 6.6 8 42 52 A + Stroke 2-FD 25 10 to 50, 75, 100 64 42 5.5 8 48 56 CE1 28 10 to 50, 75, 100 70.5 48.5 5.5 8 54 62 25, 28 CE2 Bore size (mm) FZ L M FV 10 55 18 ML2B 16 60 20 FX FT L B + Stroke 20 64 20 C J G5-S FZ 25 65 22 34 A + Stroke 4-FD 28 72
8 48 56 L B + Stroke RZQ FZ 28 10 to 50, 75, 100 104 126 5.5 8 54 62 A + Stroke 2-FD MI W S Bore size (mm) FZ L M 25, 28 CEP1 10 55 18 16 60 20 FV CE1 20 64 20 25 65 22 34 CE2 28 72 22 40 FT FX L B + Stroke FZ ML2B A + Stroke 4-FD C J G5-S Rear flange style: MQQLG 10, 16, 20 25, 28 Bore size (mm) Stroke range (mm) A L 2-FD 4-FD CV 10 10 to 40 75 8 16 10 to 60 88.5 10 MVGQ 20 10 to 60
Stabilize the source pressure by providing a tank and a vacuum regulator. Provide a vacuum switch valve to individual lines.
(mm) H1 6 7 8 11 11 H 36 40 45 53 56 GY 5 5.5 7 8 10 GX 10 8.5 9 11.5 11.5 EY 26 42 54 64 72 D 12 14 16 20 20 C 54 68 86 104 124 B1 17 19 22 27 27 BY 7 8 9 9 12 B 24 28 32 39 50 BX 9 6.5 8 10 11 ET AL 19.5 23.5 27 32 32 BS 37 45 44 54 53 K 5.5 5.5 6 7 7 A 22 26 30 35 35 BT Model MUB25 MUB32 MUB40 MUB50 MUB63 Stroke range (mm) 5 to 300 5 to 300 5 to 300 5 to 300 5 to 300 M5 x 0.8 depth 7.5
T L2 ASR ASQ Metric Size Inch Size A Model A Weight (g) Weight (g) d T H D1 D2 D3 D4 L1 L2 L3 L4 L5 L6 Model d T H D1 D2 D3 D4 L1 L2 L3 L4 L5 L6 M1 M1 AS131F-M5-23D AS131F-U10/32-01D 1/8" 8.4 3.2 8.4 19.8 19.8 17.5 12.7 17.5 12.7 28.7 10 28.7 AS131F-M5-04D AS131F-U10/32-03D 5/32" 9.3 20.3 M5 x 0.8 8 9.6 9.3 4.7 10.8 0.7 27.4 4 9.3 20.3 10 31 0.7 37.4 4.7 10.8 10-32 UNF 8 9.6 9.3 31 AS131F-M5
View A Data Terminal block number 4 3 2 1 1 2 3 4 5 6 7 8 8 7 6 5 16-11-25 22 For details about certified products conforming to international standards, visit us at www.smcworld.com.
OUT2 41.8 40.3 NC 8 Load 4 Sensor 40 4.3 OUT1 Black Main circuit Main circuit 7 3 Load Brown 6 2 Blue + SMC FLOW SWITCH 5 1 12 to 24VDC 35.8 40 A Series PF2A5 UNIT PF2A30-A RESET SET OUT2 NC 8 Load 4 Sensor OUT1 Panel fitting dimensions Black 3 x 7.2(=21.6) 7 3 Load 8-M3 36 +0.5 0 6.4 Brown 6 2 + Blue 5 1 12 to 24VDC 1 2 3 4 Series PF2A5 PF2A31-A 36 +0.5 0 19.4 Do not connect the white
When a load, such as a relay or solenoid valve, which generates surge is directly driven, use a type of switch with a built-in surge absorbing element. 8.
(mm) Weight (g) A D M5 0.8 KGH04-M5 KGH04-01 14 13 9.5 8 17 22 4 4 2.4 9 16 5.6 1 4 KGH04-02 19.5 13.5 14 4 4 1 8 16 18 10 5.6 M5 0.8 KGH06-M5 KGH06-01 KGH06-02 14 3.4 16 14 15 18.5 17 11.5 18.5 22.5 23 4 10 12 14 1 8 1 4 6 13.1 13.1 17 3 8 KGH06-03 22 15.5 17 27 21 19 26 19 30 1 8 1 4 3 8 1 8 1 4 KGH08-01 KGH08-02 KGH08-03 KGH10-01 KGH10-02 24 20.5 15.5 26 27.5 28 26.5 22 30 33.5 14
Manufacturer M4 x 0.7 M3 x 0.5 Thread size 32.5 21.5 Effective thread length (mm) 8 6 Quantity 2 4 P.C.D. 46 45 Motor mounting area When mounting a coupling on the motor, mount it within the dimensional range shown on the left. A A B Section BB P.C.D.
A at the station with the smaller number in the above figure and the B side solenoid to SOL. A at the next station. 1 2 3 4 5 6 7 8 9 10 Terminal no. (Looking it by the double solenoid valve) SOL. () A B () () A B A B A B A B Note) Types with 10, 16, or 20 pin are also available. For details, refer to page 2-4-28.
A 30 Hs Auto SWitch uto ASWltch P roper Mountm Position (mm) ' D-ASO D-A60 D-A30 D-A44 D-G39 D-K39 D-M90 D-M9OV D-M9OW D-M9OWV D-M90AL D-M90 AVL D-FSOW D-J59W D-FSBAL o.F50 D-J50 o.F59F 0.=80 o.Y5DN60 o.Y7PIY7PV o.Y70W o.Y70WV o.Y7BAL ~ switcl:l . rnod8l o.A90 o.A9OV o.A59W D-F5NTL A B A B A B A B A I B A B A B Bore size 125 9 8 13 12 6.5 5.5 3 2 7 I 6 9.5 8.5 14.5 13.5 140 9 8 13 12 6.5
-6 S 8 3 4 + B-1 5 A-1 1 + B-3 2 A-3 8 14.2 B1 A1 17.7 2 1 14 18 10.2 6 A6 B6 5 B1 A1 B3 A3 2 1 5.7 15 16 L 11 30.7 11.4 [820m] A B-1 2 A A-1 1 L B B-2 6 LE-CP-1 B A-2 5 8 8m* COM-A/COM B-3 3 COM-B/ A-3 4 A 10m* B 15m* Shield Vcc B-4 12 C 20m* GND A-4 13 A B-5 7 * * * A A-5 6 B B-6 9 B A-6 8 3 4 + B-1 5 A-1 1 + B-3 2 A-3 2 1 14 18 5.5 6.3 B1 A1 17.7 5 6 14.2
7 @5 #8 #6 #4 @6 @7 @8 @4 Auto switch $1 #5 #9 #8 #2 @3 !9 $0 $2 !1 !8 !6 #7 !0 @9 A @0 !5 A !
Note 2) Use a bushing (part no: 131368) when connecting the R 1/8 pressure gauge to the R 1/16 gauge port. Note 3) Except for AR10. Accessory part no.
port: Rc 1/8 P port: Rc 1/8 R port: Rc 1/8 Thread type Type S42 20 20 stations Solenoid on same side of A and B port Type VK334 Type VK3140 V100 S Nil Rc Q CE-compliant Nil CE-compliant Port size R port: Rc 1/8 P port: Rc 1/8 F N T G S070 1 8 NPT 01 Rc C6 6 cassette B port: Rc 1/8 A port: Rc 1/8 NPTF Note) Applicable only for DIN terminal type VQD VQD-V Common SUP/Common EXH Type 21: Body
B port) 1/4 (For mounting bracket) 2-M4 x 0.7 depth 6.5 20 7 31.5 [38.5] 40 24.5 One-touch fitting (A, B port) Applicable tubing O.D.: 8, 5/16" 10, 3/8" G: Approx. 300 H: Approx. 600 77 121.4 [125.8] (Lead wire length) 13.6 B A Manual override (For manifold mounting) 24.2 19 42 (For mounting) 23.2 (52) (66) (Light/surge voltage suppressor) 47.6 (5.5) (49.5) 16.1 (42.5) 31.5 [38.5] + 24.5
a 2 port solenoid valve is connected to the right: When 2 air catch sensors are connected or when a 2 port solenoid valve is connected to the left: Joint bracket ISA-3-A Lead wire with connector (Individual wiring type) ISA-8-A ISA-8-B Bracket ISA-4-A DIN rail mounting bracket ISA-9-A Straight, 5 m A pair consists 1 set.