Magnet: D (Built-in), Series: J2, Mounting: F (Rod Flange), Bore Size: 10mm, Stroke: 45mm, Cushion: Rubber Bumper, Head Cover Port Location: R (Axial), Pivot Bracket: None, Rod End Bracket: None, Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire, Horizontal, Lead Wire or Prewired Connector: SDPC (0.5m Cord Length, M12-4 Pin Connector), Number: 2 pcs. (Or None in the Case of No Switch
Magnet: D (Built-in Magnet), Series: J2RA, Bore Size: 16mm, Stroke: 45mm, Head Cover Port Location: R (Axial), Rod End Bracket: None, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: SAPC (0.5m Cord Length, M8-3 Pin Connector), Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting Type: A (Rail Mounting)
Magnet: D (Built-in Magnet), Series: J2RA, Bore Size: 10mm, Stroke: 45mm, Head Cover Port Location: R (Axial), Rod End Bracket: None, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: L (3m), Number: S (1 pc.), Auto Switch Mounting Type: A (Rail Mounting)
Magnet: D (Built-in Magnet), Series: J2RA, Bore Size: 16mm, Stroke: 45mm, Head Cover Port Location: R (Axial), Rod End Bracket: None, Auto Switch: M9PWV--Solid State, 2-color Indication, 3 Wire PNP, Vertical, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting Type: A (Rail Mounting)
Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 45, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~1, Cushion: Rubber cushion, Auto Switches: M9BW, Lead
Magnet: D (Built-in Magnet), Series: J2K, Mounting: F (Rod Flange), Bore Size: 16mm, Stroke: 45mm, Head Cover Port Location: R (Axial), Pivot Bracket: None, Rod End Bracket: None, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: L (3m), Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting Type: A (Rail Mounting)
Magnet: Built-in, Mounting: Basic, Bore: 16mm, Stroke: 45mm, Head Cover: Axial, Pivot Bracket: None, Rod End Bracket: None, Auto Switch: A73C--Reed, DC Volt.>5,<24, LED, Connector, Vertical, Lead Wire or Prewired Connector: 3m, Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting: Rail Mounting, Cushion: -, Series: -
Magnet: Built-in, Mounting: Single Foot, Bore: 16mm, Stroke: 45mm, Head Cover: Axial, Pivot Bracket: None, Rod End Bracket: None, Auto Switch: F79W--Solid State, 2-color Indication, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting: Rail Mounting, Cushion: -, Series: -
ZA A B t 2 x D ZX C ZM ZL ZH ZH ZH ZH -X267 ZH13 to 20DA 2 x D B ZHP A F E C ZU VQD-V Long clamping screw set for 1 station required for assembly needs to be ordered separately.
-X10 X10 X10 IZS 40 IZS 42 1660 1660 10 10 B B Ordering example) Bar length Type 41 42 520 700 760 880 940 1000 1060 1180 1240 1360 1420 1480 1540 1660 1720 1780 1840 1960 2020 2080 2140 2200 2260 2380 2440 Symbol Specifications Contents Model with drop prevention cover The main unit is shipped fitted with a drop prevention cover available as an option.
(Part1:General requirements) ISO 10218-1992:Manipulating industrial robots -Safety JIS B 8370: JIS B 8361: JIS B 9960-1:-((1 :) JIS B 8433-1993: 2) : : : 1 2. 3. 1. 2. 3. 4. 2 No.LFE*-OMY0008 / 1 1.5 3 3) 1 1 () [] 3 No.LFE*-OMY0008 () () () () 4 No.LFE*-OMY0008 () * (100 20 ) () <> 2MPa 5 No.LFE*-OMY0008 * (1623 ) FG (49N ) () M12 IN IN OUT OUT OUT OUT () 6 No.LFE
Cv = Area x Stroke x A x Cf Time x 29 Area = x Radius 2 or see table B below. Stroke = Cylinder Travel (in.) A = Pressure Drop Constant (see table A) Cf = Compression Factor (see table A) Table B Cylinder Area (Sq. In.)
Cv = Area x Stroke x A x Cf Time x 29 Area = x Radius 2 or see table B below. Stroke = Cylinder Travel (in.) A = Pressure Drop Constant (see table A) Cf = Compression Factor (see table A) Table B Cylinder Area (Sq. In.)
A B C E Applicable clip Clip for P7 Clip for P10 Conforms to JIS B 2401 dimensional standard for O-rings for industrial applications.
Optuon B ventilation air outlet Earth leakage breaker Handle Lid for circulating fluid fill port (There is a handle on the other side too.)
Surface B Hexagon socket head set screw Slide table Gasket (apply grease) Replacement shock absorber Guide Cylinder fixing bolts End cover Mounting hole (round hole) Surface B Surface C Surface A Slider Actuator (cylinder) Mounting hole (Oval hole) Enlarged view of end cover Surface A Enlarged view end cover 3. Be sure to fasten the cylinder fixing bolts.
+ Stroke Dimensions (mm) A B GB Bore size 40 63 100 58 48.5 36.5 GB 73 61.5 38 78 66.5 38 Dimensions not listed above are the same as the standard model.
e Order No. b d f l1 c a 32 M10x1.25 GKM10-20 10 40 10 52 20 20 40 M12x1.25 GKM12-24 12 48 12 62 24 24 50/63 M16x1.5 GKM16-32 16 64 16 83 32 32 80/100 M20x1.5 GKM20-40 20 80 20 105 40 40 Rod end nut (standard equipment) 30 d D C H B Bore size (mm) Order No.
D-A9V D-F9V D-F9WV A 22 (20) 5 (7) W B The dimension in ( ) is for D-F9V and D-F9WV. (mm) D-A9, D-A9V D-F9, D-F9W D-F9V, D-F9WV Bore size (mm) A A W B W B W A B 20 25 32 22 22 13 (10.5) 19 18 9 19 11 15 24.5 24.5 9 (6.5) 15 20 5 15 7 11 26.5 26.5 11.5 (9) 17.5 22.5 7.5 17.5 9.5 13.5 Values in ( ) are dimensions for D-A93 type.
A B C A B C A B C A B C 1/8" 1/8" 1/4" 1/8" 1/4" 3/8" 1/4" 3/8" 1/2" 3/8" 1/2" 3/4" 1/2" 3/4" 1" Tubing Connection E 1A LQ3 Size Combination Class Fitting Style Symbol E T P U Combination 1 2 3 4 5 6 Tube Size (Inch) 1/8" x 0.086" 1/4" x 5/32" 3/8" x 1/4" 1/2" x 3/8" 3/4" x 5/8" 1" x 7/8" Style Elbow Union Tee Union Panel Union Straight Union A A A A A A Series LQ3 Dimensions Straight Male