SMC Corporation of America
Elite Part Number Search
Search Results "LEFS25EA-200-R5C918"

Fluid: air/inert gas, Operating pressure range: 0.10 - 1.0MPa, Effective area mm 2 (Cv): 2 position metal seal 72.0 (4.0); 2 position rubber seal 79.2 (4.4) 3 position metal seal 41.4 (2.3) - 72.0 (4.0); 3 position rubber seal 45.0 (2.5) - 79.2 (4.4), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W: metal seal 20 or less to 62 or less; rubber seal 25 or

Fluid: air/inert gas, Operating pressure range: 0.10 - 1.0MPa, Effective area mm 2 (Cv): 2 position metal seal 72.0 (4.0); 2 position rubber seal 79.2 (4.4) 3 position metal seal 41.4 (2.3) - 72.0 (4.0); 3 position rubber seal 45.0 (2.5) - 79.2 (4.4), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W: metal seal 20 or less to 62 or less; rubber seal 25 or

AIR DRYER, MEMBRANE(200/50)-20. OTHERS . IDG 3/8 MEMBRANE AIR DRYER . 1.83717 lb.

Fluid: air/inert gas, Operating pressure range: 0.1 - 0.7MPa (high pressure type 0.8MPa), Effective area mm 2 (Cv): 2 position metal seal 14.4 (0.8); 2 position rubber seal 16.2 (0.9) 3 position metal seal 12.6 (0.7); 3 position rubber seal 14.4 (0.8), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, H 1.5W: metal seal 29 or less; rubber seal 34 or less

Fluid: air/inert gas, Operating pressure range: 0.1 - 0.7MPa (high pressure type 0.8MPa), Effective area mm 2 (Cv): 2 position metal seal 14.4 (0.8); 2 position rubber seal 16.2 (0.9) 3 position metal seal 12.6 (0.7); 3 position rubber seal 14.4 (0.8), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, H 1.5W: metal seal 29 or less; rubber seal 34 or less

Standard: single acting, single rod, spring return/extend, Bore sizes *: 20, 25, 32, 40, Strokes *: 25~200, Mounts: basic, foot, front or rear flange, front or rear trunnion, clevis, Auto switch capable with a variety of lead wire lengths ROUND BODY CYLINDER. CG1, Air Cylinder. 1.65 lb. 335.

Series: NCDA1 (Standard w/ Magnet), Mounting: U (MT1, Rod Trunnion), Bore Size: 200 (2"), Stroke: 5000 (50"), Air Cushion / Rod Boot: Both Ends (Air Cushion), Thread: Nil (Small Male, Standard, Threaded), Adjustment Range: Not Applicable, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs.

Fluid: air/inert gas, Operating pressure range: 0.1 - 0.7MPa (high pressure type 0.8MPa), Effective area mm 2 (Cv): 2 position metal seal 14.4 (0.8); 2 position rubber seal 16.2 (0.9) 3 position metal seal 12.6 (0.7); 3 position rubber seal 14.4 (0.8), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, H 1.5W: metal seal 29 or less; rubber seal 34 or less

Fluid: air/inert gas, Operating pressure range: 0.10 - 1.0MPa, Effective area mm 2 (Cv): 2 position metal seal 72.0 (4.0); 2 position rubber seal 79.2 (4.4) 3 position metal seal 41.4 (2.3) - 72.0 (4.0); 3 position rubber seal 45.0 (2.5) - 79.2 (4.4), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W: metal seal 20 or less to 62 or less; rubber seal 25 or

Fluid: air/inert gas, Operating pressure range: 0.15 - 1.0MPa, Effective area mm 2 (Cv): 2 position metal seal 36.0 (2.0); 2 position rubber seal 39.6 (2.2) 3 position metal seal 19.8 - 36.0 (1.1 - 2.0); 3 position rubber seal 21.6 - 39.6 (1.2 - 2.2), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W: metal seal 12 or less to 55 or less; rubber seal 15 or

SY is available in body ported or base mounted styles and can be used individually or manifold mounted.Fluid: air , Operating pressure range: (internal pilot) 0.1 - 0.7MPa (external pilot) -100kPa to 0.7MPa (external pilot, pilot pressure range) 0.25 - 0.7MPa , Effective area mm 2 (Cv): body ported 10.6 (0.59); base mounted 12.6 (0.7) , Coil rated voltage: 3, 5, 6, 12, 24VDC; 100, 110, 200

Fluid: air/inert gas, Operating pressure range: 0.15 - 1.0MPa, Effective area mm 2 (Cv): 2 position metal seal 36.0 (2.0); 2 position rubber seal 39.6 (2.2) 3 position metal seal 19.8 - 36.0 (1.1 - 2.0); 3 position rubber seal 21.6 - 39.6 (1.2 - 2.2), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W: metal seal 12 or less to 55 or less; rubber seal 15 or

SY is available in body ported or base mounted styles and can be used individually or manifold mounted.Fluid: air , Operating pressure range: (internal pilot) 0.1 - 0.7MPa (external pilot) -100kPa to 0.7MPa (external pilot, pilot pressure range) 0.25 - 0.7MPa , Effective area mm 2 (Cv): body ported 10.6 (0.59); base mounted 12.6 (0.7) , Coil rated voltage: 3, 5, 6, 12, 24VDC; 100, 110, 200

Fluid: air/inert gas, Operating pressure range: 0.15 - 1.0MPa, Effective area mm 2 (Cv): 2 position metal seal 36.0 (2.0); 2 position rubber seal 39.6 (2.2) 3 position metal seal 19.8 - 36.0 (1.1 - 2.0); 3 position rubber seal 21.6 - 39.6 (1.2 - 2.2), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W: metal seal 12 or less to 55 or less; rubber seal 15 or

Fluid: air/inert gas, Operating pressure range: 0.15 - 1.0MPa, Effective area mm 2 (Cv): 2 position metal seal 36.0 (2.0); 2 position rubber seal 39.6 (2.2) 3 position metal seal 19.8 - 36.0 (1.1 - 2.0); 3 position rubber seal 21.6 - 39.6 (1.2 - 2.2), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W: metal seal 12 or less to 55 or less; rubber seal 15 or

SY is available in body ported or base mounted styles and can be used individually or manifold mounted.Fluid: air , Operating pressure range: (internal pilot) 0.1 - 0.7MPa (external pilot) -100kPa to 0.7MPa (external pilot, pilot pressure range) 0.25 - 0.7MPa , Effective area mm 2 (Cv): body ported 10.6 (0.59); base mounted 12.6 (0.7) , Coil rated voltage: 3, 5, 6, 12, 24VDC; 100, 110, 200

SY is available in body ported or base mounted styles and can be used individually or manifold mounted.Fluid: air , Operating pressure range: (internal pilot) 0.1 - 0.7MPa (external pilot) -100kPa to 0.7MPa (external pilot, pilot pressure range) 0.25 - 0.7MPa , Effective area mm 2 (Cv): body ported 10.6 (0.59); base mounted 12.6 (0.7) , Coil rated voltage: 3, 5, 6, 12, 24VDC; 100, 110, 200

Standard: single acting, single rod, spring return/extend, Bore sizes *: 20, 25, 32, 40, Strokes *: 25~200, Mounts: basic, foot, front or rear flange, front or rear trunnion, clevis, Auto switch capable with a variety of lead wire lengths ROUND BODY CYLINDER. CG1, Air Cylinder. 0.25 lb.

SY is available in body ported or base mounted styles and can be used individually or manifold mounted.Fluid: air , Operating pressure range: (internal pilot) 0.1 - 0.7MPa (external pilot) -100kPa to 0.7MPa (external pilot, pilot pressure range) 0.25 - 0.7MPa , Effective area mm 2 (Cv): body ported 10.6 (0.59); base mounted 12.6 (0.7) , Coil rated voltage: 3, 5, 6, 12, 24VDC; 100, 110, 200

SY is available in body ported or base mounted styles and can be used individually or manifold mounted.Fluid: air , Operating pressure range: (internal pilot) 0.1 - 0.7MPa (external pilot) -100kPa to 0.7MPa (external pilot, pilot pressure range) 0.25 - 0.7MPa , Effective area mm 2 (Cv): body ported 10.6 (0.59); base mounted 12.6 (0.7) , Coil rated voltage: 3, 5, 6, 12, 24VDC; 100, 110, 200