Type of Actuation: 2 (2 Position Double), Manifold Type: 40 (Base Mounted), Pilot: Internal Pilot, Specifications: Standard, Voltage: 3 (110VAC 50/60HZ), Electrical Entry: D (DIN Terminal w/Connector), Lead Wire Length: None, Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: D (Push-turn Locking Slotted Style), Port Size: 02 (Body Ported 1/4, Base Mounted Sub-plate 1/4), Thread
Body Size: 20, Thread: Rc, Port: 02 (1/4), Option: E [Square embedded type pressure gauge (with limit indicator)], Attachment: Standard, Semi-Standard 1: 2 (Metal Bowl), Semi-Standard 2: Standard
Body Size: 20, Thread: N (NPT), Port Size: 02 (1/4), Option: BC (B + C), Semi-Standard 1: 2R (2 + R), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F)
Body Size: 20, Thread: N (NPT), Port Size: 02 (1/4), Option: B (Assembly of a Bracket and Set Nuts), Semi-Standard 1: 2 (Metal Bowl), Semi-Standard 2: Z (NPT Porting requires Z, Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F)
Body Size: 20, Thread: N (NPT), Port: 02 (1/4), Option: C [Float Type Auto Drain (N.C.)], Attachment: Standard, Semi-Standard 1: 2 (Metal Bowl), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, and Pressure Gauge: psi, °F)
Body Size: 30, Thread: N (NPT), Port Size: 02 (1/4), Option: Standard, Attachment: Standard, Semi-Standard 1: 2 (Metal Bowl), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F)
Configuration: 2 (2 Position Double), Sealant: 1 (Rubber Seal), Function: Standard (1W), Coil Voltage: 5 (24VDC), Light & Surge Suppressor: w/Light and Surge Suppressor, Manual Override: Non-locking Push Style, 1: 1, Porting Specification: B (Bottom Ported), Port Size: 02 (1/4)
Type of Actuation: 1 (2 Position Single), Manifold Type: 20 (Body Ported), Pilot: Internal Pilot, Specifications: Standard, Voltage: 2 (200VAC 50/60HZ), Electrical Entry: D (DIN Terminal w/Connector), Lead Wire Length: None, Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style, Port Size: 02 (Body Ported 1/4, Base Mounted Sub-plate 1/4), Thread: T (NPTF)
Function: 2 (2 Position Double), Body Option: 10 (Base Mounted Non Plug-in), Pilot: Internal Pilot, Voltage: 5 (24VDC), Lead Wire: D (DIN Terminal w/Connector), Surge Suppressor: None, Manual Override: Non-locking Push Style (Flush), Port Size: 02 (Base Mounted w/Sub-plate 1/4 Side Piping), Thread: N (NPT)
Body Size: 20, Thread: N (NPT), Port: 02 (1/4), Option: Standard, Attachment: Standard, Semi-Standard 1: 12J (1 + 2 + J), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, and Pressure Gauge: psi, °F)
Stations: 3 Stations, Port Size: 02 (Rc1/4), Electrical Entry Direction: D (Plug-in L Kit D Side), Cable Length: 2 (3.0m Cable), Control Unit: None, Release Valve Rated Voltage: w/o Air Release Valve, Option 1: None, Option 2: W (IP65 Protection Compatible)
Body Size: 20A, Thread: N (NPT), Port Size: 02 (1/4), Option: G (for Sizes 20, 25, 30, 40 Round Type Pressure Gauge w/Limit Indicator; for Size10: Round Type Pressure Gauge w/o Limit Indicator), Attachment: V (3-Port Valve for Residual Pressure Release), Semi-Standard 1: 2 (Metal Bowl), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F)
Type of Actuation: 2 (2 Position Double), Manifold Type: 40 (Base Mounted Non Plug-in Single/Stacking Base, Plug-in Stacking Base), Pilot: Internal Pilot, Specifications: Standard, Voltage: 6 (12VDC), Electrical Entry: D (DIN Terminal w/Connector), Lead Wire Length: None, Surge Suppressor: None, Manual Override: Non-locking Push Style, A, B Port Size: 02 (Base Mounted w/Sub-plate 1/4), Thread
Actuation Type: 2 (2 Position Double), Sealant: 0 (Metal Seal), Function: Standard (1W), Voltage: 5 (24VDC), Lead Wire: H (Grommet Lead Wire 1.5m), Light & Surge Suppressor: Yes, Manual Override: Non-locking Push Style, Protection: Dust Proof, 1: 1, Piping Specification: Side Ported, Port Size: 02 (Rc1/4)
Body Size: 2 (1/8, 1/4), Type: 2 (Elbow), Control Type: 0 (Meter-out), Thread: N (NPT), Port Size: 02 (1/4), Applicable Tubing O.D.: 04 (ø4), Seal: S (w/Sealant)
Size: No.2, Orifice: 3 (4.5mm), Style: 2 (Normally Open), Option: G (For Air and Water -- Seal: NBR, Body: Stainless Steel), Port Size: 02 [1/4 (8A)], Thread: N (NPT)
Body Size: 2 (1/8, 1/4), Type: 3 (Universal), Control Type: 0 (Meter-out), Control Range: FM (1 to 50 mm/s), Indicator Window Direction: 0° , or None for FC, FM, Thread: R, Port Size: 02 (1/4), Width Across Flats [H]: 9mm or None for Body Size 2, Tube Size: 08 (ø8), Sealant: S (with Sealant), Push lock: A (Push-lock)
Body Size: 2 (1/8, 1/4), Type: 3 (Universal), Control Type: 0 (Meter-out), Control Range: FM (1 to 50 mm/s), Indicator Window Direction: 0° , or None for FC, FM, Thread: R, Port Size: 02 (1/4), Width Across Flats [H]: 9mm or None for Body Size 2, Tube Size: 10 (ø10), Sealant: S (with Sealant), Push lock: A (Push-lock)
Body Size: 40, Thread: None (Rc: for Body Size 20, 30, 40, 50, 60; M5: for Body Size 10), Port Size: 02 (1/4), Option: B (Bracket), Semi-Standard 1: 2 (Metal Bowl), Semi-Standard 2: Standard, Made to Order: X2141 (w/Element Service Indicator)
Actuation: 2 (2 Position Double), Seal: 0 (Metal Seal), Function: Standard (0.4W DC, AC), Coil Voltage: 5 (24VDC), Light & Surge Suppressor: Yes, Manual Override: Non-locking Push Style (Tool Required), Enclosure: W [Dust-tight, Water-jet-proof (IP65)], Sub-plate: 02 (1/4 Port Size), Thread: F (G)