Magnet: Built-in, Mounting: Rear Flange, Bore Size: 4", Stroke A: 20", Cushion A: Both Ends, Rod Boot A: None, Stroke B: 20", Cushion B: Both Ends, Rod Boot B: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Dual, Tandem Option: Dual Op., Sgl. Rod
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYLINDER, ACTUATOR, NCA1 TIE-ROD CYLINDER, SD, 4 INCH NCA1 DOUBLE-ACTING, .00000 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYLINDER, ACTUATOR, NCA1 TIE-ROD CYLINDER, RE, 3.25 INCH NCA1 DBL-ACT AUTO-SW, .00000 lb
Series NCA1 medium duty tie rod cylinders are NFPA interchangeable, have a crimped piston rod assembly, are pre-lubricated and available in 11 mounting styles. Bore sizes range from 1.5 to 4 inches. The NCA1 expanded line of medium duty cylinders offer bore sizes ranging from 5 to 8 inches, and come standard with adjustable air cushion.5in. bore medium duty air cylinder, 11 NFPA mounting
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYLINDER, ACTUATOR, NCA1 TIE-ROD CYLINDER, VD, 6 INCH NCA1 DOUBLE-ACTING, 151.958 lb
The NCG provides precision mounting, short overall length, and high speed. Rubber bumpers are standard and an optional adjustable air cushion is available. Nine mounting styles include basic body, foot, single clevis, front or rear flange, front or rear trunnion, nose mount, and double clevis. Bore sizes range from 3/4in. to 2 1/2in. and standard stroke lengths from 1in. to 12in.. The NCG
The NCG provides precision mounting, short overall length, and high speed. Rubber bumpers are standard and an optional adjustable air cushion is available. Nine mounting styles include basic body, foot, single clevis, front or rear flange, front or rear trunnion, nose mount, and double clevis. Bore sizes range from 3/4in. to 2 1/2in. and standard stroke lengths from 1in. to 12in.. The NCG
The NCG provides precision mounting, short overall length, and high speed. Rubber bumpers are standard and an optional adjustable air cushion is available. Nine mounting styles include basic body, foot, single clevis, front or rear flange, front or rear trunnion, nose mount, and double clevis. Bore sizes range from 3/4in. to 2 1/2in. and standard stroke lengths from 1in. to 12in.. The NCG
The NCG provides precision mounting, short overall length, and high speed. Rubber bumpers are standard and an optional adjustable air cushion is available. Nine mounting styles include basic body, foot, single clevis, front or rear flange, front or rear trunnion, nose mount, and double clevis. Bore sizes range from 3/4in. to 2 1/2in. and standard stroke lengths from 1in. to 12in.. The NCG
Series NCM stainless steel cylinder offers space savings, high performance, and interchangeability with other stainless steel cylinders. A wear ring extends the seal life and a bronze rod bushing is standard on all bore sizes. The NCM is available in 4 mounting styles * as well as double rod and spring return or spring extend models. The NCM is auto-switch capable without any change in cylinder
Series NCA1 medium duty tie rod cylinders are NFPA interchangeable, have a crimped piston rod assembly, are pre-lubricated and available in 11 mounting styles. Bore sizes range from 1.5 to 4 inches. The NCA1 expanded line of medium duty cylinders offer bore sizes ranging from 5 to 8 inches, and come standard with adjustable air cushion.5in. bore medium duty air cylinder, 11 NFPA mounting
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYLINDER, ACTUATOR, NCA1 TIE-ROD CYLINDER, TD, 5 INCH NCA1 DOUBLE-ACTING, 6.14 lb
The NCG provides precision mounting, short overall length, and high speed. Rubber bumpers are standard and an optional adjustable air cushion is available. Nine mounting styles include basic body, foot, single clevis, front or rear flange, front or rear trunnion, nose mount, and double clevis. Bore sizes range from 3/4in. to 2 1/2in. and standard stroke lengths from 1in. to 12in.. The NCG
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYLINDER, ACTUATOR, NCA1 TIE-ROD CYLINDER, MD, 1.5 INCH NCA1 DOUBLE-ACTING
CY36 Consult with SMC in case a bracket with weight exceeding the above value is to be mounted. 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 1000 2000 3000 4000 5000 6000 CY315 Note 1) According to the dead weight deflection in the figure on the right, provide clearance so that the cylinder does not touch the mounting surface or the load, etc., and is able
(53.8) 0.69 (17.5) Max. 5.0 (127.0) Max. 5.6 (142.2) (When selecting option code P) 1.5 (38.1) 2.25 (57.2) 2.00 (50.8) A 0.88 (22.4) Connections inch A (mm) 2 x 10-32 UNF depth 0.25 (6.3) (Mounting hole) FV4 MV4 FV6 MV6 TW6 3.70 (94.0) 4.70 (119.4) 2.96 (75.2) Flow Characteristics AZ1500 100 psig (0.69 MPa) 40 psig (0.28 MPa) Inlet pressure: 80 psig (0.55 MPa) 20 psig (0.14 MPa) AZ1500 2000
2000 0.3 MPa 0 50 100 150 200 250 300 0 50 100 150 200 250 300 Arm length [mm] Arm length [mm] Bore size: 63, Arm length: 200 mm, Operating pressure: 0.5 MPa With an arm length of 200 mm and an operating pressure of 0.5 MPa, according to the graph, the maximum clamping force is 2000 N.
Table (1) Indication of Flow-rate Characteristics Indication by Corresponding Other Conformed standard international standard equipment indications ISO 6358: 1989 JIS B 8390: 2000 C, b Pneumatic equipment JIS B 8390: 2000 Equipment: JIS B 8373, 8374, 8375, 8379, 8381 S Cv ANSI/(NFPA)T3.21.3: 1990 IEC60534-2-3: 1997 JIS B 2005: 1995 Equipment: JIS B 8471, 8472, 8473 Process fluid Av control
(Value in the initial state) Vibration resistance: No malfunction occurred in a one-sweep test between 45 and 2000 Hz in the axial direction and at a right angle to the main valve and armature in both an energized and a de-energized state, once in each condition.
O~ 0.2 0.3 04 05 0.6 O~ 08 09 00 1000 2000 Auto drain Flow rate /min (ANR) Inlet pressure MPa (Float type normally open) AW4001-04 AW4001 -04 OOrain line should be Bmm or more and should be less than Sm. Be sure not to have any upward turns in the drain line which would prevent drainage. -0.25 H---''t' .:c ' +-+-t---+--r--.