SMC Corporation of America
Elite Part Number Search
Search Results "VNA111A-6A-5EZA-B"

Displays in turn Normal output Bracket A M3x5 L M3x5 L Bracket B M3x5 L Bracket C Reversed output : The bracket A/B/C can be mounted in 4 ways. Safety Instructions 3. Press the or button to change the set value. The button is to increase and the button is to decrease. Press the button once to increase by one digit, and press it continuously to keep increasing the set value.

Maintenance Bracket A or D(Model: ZS-24-A/ZS-24-D) Bracket B (Model: ZS-24-B) [01/N01 type] [W1/WF1 type] Operator How to reset the product after power cut or forcible de-energizing The setting of the product will be retained as it was before a power cut or de-energizing.

.: ZS-50-A) Bracket B (Part No.: ZS-50-B) Thank you for purchasing an SMC ISE70/ISE71/ISE70G/ISE75G/ISE76G/ ISE77G/ISE78G Series High-precision Digital Pressure Switch. Please read this manual carefully before operating the product and make sure you understand its capabilities and limitations. Please keep this manual handy for future reference.

Bracket B (Part No.: ZS-50-B) Unit specification ["Nil" or M]: MPa Display unit Safety Instructions Display colour Output ON: Green/Output OFF: Red (Linked to OUT1) Switch output specifications PNP : Arbitrary display Mode display [F 2] Setting of OUT2 Same setting as [F 1] OUT1. These safety instructions are intended to prevent hazardous situations and/or equipment damage.

SPEEDCON connector wiring method is explained below. (1)Align the mark B on the metal bracket of the cable side connector (plug/socket) with the mark A. Wiring Setting1 Setting and Adjustment Address X10 OFF OFF OFF OFF (3)When the mark B of the connector has been turned 180 degrees (1/2 turn), wiring is completed. Confirm that the connection is not loose.

SPEEDCON connector wiring method is explained below. (1)Align the mark B on the metal bracket of the cable side connector (plug/socket) with the mark A. Wiring Settings1 Terminator Address Setting and Adjustment OFF OFF (3)When the mark B of the connector has been turned 180 degrees (1/2 turn), wiring is completed. Confirm that the connection is not loose.

SPEEDCON connector wiring method is explained below. (1)Align the mark B on the metal bracket of the cable side connector (plug/socket) with the mark A. Wiring Setting and Adjustment Address X10 OFF OFF OFF OFF OFF OFF OFF OFF 10 Mbps OFF OFF ON OFF OFF (3)When the mark B of the connector has been turned 180 degrees (1/2 turn), wiring is completed.

, EA, EB portA, B portSS5X5-20SX5 20Single base/B mountCommon SUP/Common EXH2 to 20 stationsValveRc 1 4Rc 1 8C4 (One-touch fitting ?

, EA, EB portA, B portSS5X5-41SX5 40Single base/B mountCommon SUP/Common EXH2 to 20 stationsBaseSideRc 1 4Rc 1 8C6 (One-touch fitting for ?

Magnet: D (Built-in), Mounting: B (Through Hole, Standard), Bore Size: 32mm, Water Resistant: None, Port Thread: TF (Bore 20: M5 Thread, Bore 32 to 50: G), Stroke: 20mm, Action: D (Double Acting), Rod End: B (Lever Type, Adjustable Absorber Type), Direct Mount Switch Groove: Z (Direct Mount Switch Groove), Mounting Bolt: L (Shipped Together Only for Mounting B)

Magnet: None, Mounting: B (Through Hole, Standard), Bore Size: 32mm, Water Resistant: None, Port Thread: Bore 12, 16: M Thread; Bore 20 to 50: Rc, Stroke: 20mm, Action: T (Single Acting/Spring Extend), Rod End: B (Lever Type, Adjustable Absorber Type), Direct Mount Switch Groove: Z (Direct Mount Switch Groove), Mounting Bolt: L (Shipped Together Only for Mounting B)

Magnet: D (Built-in), Mounting: B (Through Hole, Standard), Bore Size: 32mm, Water Resistant: None, Port Thread: Bore 12, 16: M Thread; Bore 20 to 50: Rc, Stroke: 20mm, Action: T (Single Acting/Spring Extend), Rod End: B (Lever Type, Adjustable Absorber Type), Direct Mount Switch Groove: Z (Direct Mount Switch Groove), Mounting Bolt: L (Shipped Together Only for Mounting B), Auto Switch:

Magnet: D (Built-in), Mounting: B (Through Hole, Standard), Bore Size: 40mm, Water Resistant: None, Port Thread: Bore 12, 16: M Thread; Bore 20 to 50: Rc, Stroke: 20mm, Action: B (Double Acting/Spring Loaded), Rod End: B (Lever Type, Adjustable Absorber Type), Direct Mount Switch Groove: Z (Direct Mount Switch Groove), Mounting Bolt: None, Auto Switch: M9B--Solid State , Gen.

Magnet: D (Built-in), Mounting: B (Through Hole, Standard), Bore Size: 32mm, Water Resistant: None, Port Thread: Bore 12, 16: M Thread; Bore 20 to 50: Rc, Stroke: 15mm, Action: D (Double Acting), Rod End: B (Lever Type, Adjustable Absorber Type), Direct Mount Switch Groove: Z (Direct Mount Switch Groove), Mounting Bolt: L (Shipped Together Only for Mounting B)

Magnet: D (Built-in), Mounting: B (Through Hole, Standard), Bore Size: 50mm, Water Resistant: None, Port Thread: TN (NPT), Stroke: 25mm, Action: B (Double Acting/Spring Loaded), Rod End: B (Lever Type, Adjustable Absorber Type), Direct Mount Switch Groove: Z (Direct Mount Switch Groove)

Magnet: D (Built-in), Mounting: B (Through Hole, Standard), Bore Size: 32mm, Water Resistant: None, Port Thread: F (Built-in One-touch Fitting), Stroke: 20mm, Action: B (Double Acting/Spring Loaded), Rod End: Round Bar Style, Direct Mount Switch Groove: Z (Direct Mount Switch Groove), Mounting Bolt: L (Shipped Together Only for Mounting B)

Magnet: None, Mounting: B (Through Hole, Standard), Bore Size: 40mm, Water Resistant: None, Port Thread: Bore 12, 16: M Thread; Bore 20 to 50: Rc, Stroke: 20mm, Action: B (Double Acting/Spring Loaded), Rod End: B (Lever Type, Adjustable Absorber Type), Direct Mount Switch Groove: Z (Direct Mount Switch Groove)

Magnet: None, Mounting: B (Through Hole, Standard), Bore Size: 40mm, Water Resistant: None, Port Thread: Bore 12, 16: M Thread; Bore 20 to 50: Rc, Stroke: 30mm, Action: B (Double Acting/Spring Loaded), Rod End: F (Round Bar w/Female Rod End), Direct Mount Switch Groove: Z (Direct Mount Switch Groove), Mounting Bolt: L (Shipped Together Only for Mounting B)

Magnet: D (Built-in), Mounting: B (Through Hole, Standard), Bore Size: 16mm, Water Resistant: None, Port Thread: Bore 12, 16: M Thread; Bore 20 to 50: Rc, Stroke: 15mm, Action: B (Double Acting/Spring Loaded), Rod End: Round Bar Style, Direct Mount Switch Groove: Z (Direct Mount Switch Groove), Mounting Bolt: L (Shipped Together Only for Mounting B)

Magnet: D (Built-in), Mounting: B (Through Hole, Standard), Bore Size: 50mm, Water Resistant: None, Port Thread: Bore 12, 16: M Thread; Bore 20 to 50: Rc, Stroke: 20mm, Action: B (Double Acting/Spring Loaded), Rod End: B (Lever Type, Adjustable Absorber Type), Direct Mount Switch Groove: Z (Direct Mount Switch Groove)