AMV6-14 AMV15-20 AMV37-20 AMV75-30 AMV160-40 1.6 3.0 5.9 10 43 59 0.3 0.5 1.0 1.0 10 10 360 650 1,500 3,700 7,500 16,000 1 1 1/2 2 2 80 (3B) JIS 10K FF flange 360 650 1,500 3,700 7,500 16,000 100 (4B) JIS 10K FF flange Construction Gasket Cover Element Tension bolt No Description Material Component Parts 1 2 3 4 Holder Case Cover Tension bolt Aluminum alloy Carbon steel Carbon steel Carbon
e MO XB T-slot dimensions (mm) DM HN XAH7 XC XL Bore size (m) a b c d e End lock mechanism (locking type manual release ) 6.5 10.5 5.5 3.5 9.5 32 Section XX detailed diagram 6.5 10.5 5.5 4 11 40 8.5 13.5 7.5 4.5 13.5 50 11 17.8 10 7 18.5 63 LL With rear lock (mm) Standard strokes (mm) Bore size (mm) ML NN OA B C DA FA FB G GA GB GC H HA J K L MM 84.5 62.5 16 12 10 48 12.5 9 12.5 112 M6 24
Fittings & Tubing Air Cylinders Rotary Actuators How to Order Clean series 10 11 Relief type Vacuum suction type Nil Built-in magnet No D With auto switch (Built-in magnet) 10 C D M 2 X L 40 150 Z M9BW Low speed cylinder Mounting Basic (Double-side bossed) Axial foot Rod flange Head flange Boss-cut, Basic Boss-cut, Rod flange B L F G BZ FZ Auto switch Nil Without auto switch For applicable
Model: 10 (Side Ported), Connector Type: F (D-sub Connector, IP40, 25 Pins), Connector Entry Direction: 1 (Upward), Valve Stations: 10 Stations, P,E Port Location: D (D Side, 2 to 10 Stations), SUP/EXH Block: R (External Pilot), A,B Port Size: C8 (ø8 One-touch Fitting)
Model: 10 (Side Ported), Connector Type: F (D-sub Connector, IP40, 25 Pins), Connector Entry Direction: 1 (Upward), Valve Stations: 10 Stations, P,E Port Location: D (D Side, 2 to 10 Stations), SUP/EXH Block: Internal Pilot, A,B Port Size: LN11 (ø3/8" One-touch Fitting)
The drain pipe must have a minimum pipe bore of 10 mm, and a maximum length of 5 m (when installing an optional auto-drain).
The SY is available in body ported or base mounted styles, and can be used individually or manifold mounted.Plug-in connector connecting base, Side ported, Available with external pilot, Connector types: D-sub, Flat ribbon cable (26, 20 or 10 pins), PC wiring, One-touch fittings, MFLD ASSY, 10-STA, VALVE, SS5Y3 MANIFOLD SY3000, UM, SS5Y3 BUILT IN FITTING
Printed in Japan. 1st printing November, 1999 D-SMC.L.A. P-80 (YG)
10 8 8 10 10 12 15 40 50 55 66 80 88 84 100 110 28 34 50 5 5 9 26 32 37 37 37 37 13 16 19 20 22 25 108 155 221 1/4, 3/8 3/8, 1/2 1/2, 3/4 3 Series AMP Model Selection Selection Caution Caution 1.
Printed in Japan. 1st printing November, 1999 D-SMC.L.A. P-80 (YG)
Series: 1 (JSY1000), Type: 10 (Side-Ported), Connector Type: T (Terminal Block Box), Valve Stations: 10 Stations, P,E Port Location: D (D Side, 2 to 10 Stations), SUP/EXH Block: Internal Pilot, A,B Port Size: C6 (ø6 One-touch Fitting), Mounting: D (DIN Rail Mounting), DIN Rail Option: 0 (DIN Rail Mounting, w/o DIN Rail)
Series: 3 (JSY3000), Type: 10 (Side-Ported), Number of Cores - Lead Wire: L1 (34 Cores), Lead Wire Length: 1 (0.6m), Valve Stations: 10 Stations, P,E Port Location: D (D Side, 2 to 10 Stations), SUP/EXH Block: Internal Pilot, A,B Port Size: C8 (ø8 One-touch Fitting), Mounting: D (DIN Rail Mounting)
-02 Round Square embedded type Round Square embedded type G46-10-02 G36-10-01 1.0MPa Note 3) GC3-10AS Note 2) GC3-10AS GC3-10AS 1 4 1 8 1 4 Note 1) Pressure gauge G46-2-02 G36-2-01 G46-2-02 Set pressure + 0.05MPa (at relief flow rate of 0.1l/min(ANR)) 5 to 60C (With no condensation) 5m 0.2MPa Note 3) GC3-2AS GC3-2AS GC3-2AS Note 4) AD48 N.O.
SET-ON (10) Start readiness signal Indicates operation in progress when ON. ON when program is being executed and when returning to the home position. BUSY (11) Operating signal COM +24V 1 COM 11 GND NO.0 When this signal is off, an alarm is being generated for the actuator/controller.
COM.(2) DC 24V 12V S,Z 1V R,U 47V 32V 3 3 A B , 10 No.SY3000V-OMY0001 SY series DIN a b DIN DIN DIN 25 2 610 3 1115 4 1620 5 2124 6 DIN DIN DIN A B a b 5 D PC 1 D (IP40) PC FREE LOCK LOCK FREE 11 No.SY3000V-OMY0001 SY series AB 4(A),2(B),1(P),3/5(E) 12 No.SY3000V-OMY0001 SY series 1) 0.1mm 2) 0.1mm 3) +0.15mm 0.2mm 1) TK-123 , 2) 13 No.SY3000V-OMY0001 SY series
Model: 10 (Side Ported), Connector Type: F (D-sub Connector, IP40, 25 Pins), Connector Entry Direction: 1 (Upward), Valve Stations: 10 Stations, P,E Port Location: D (D Side, 2 to 10 Stations), SUP/EXH Block: Internal Pilot, A,B Port Size: N11 (ø3/8" One-touch Fitting)
Connector Type: FD (D-sub Connector, 25 Pins), Connector Entry: 1 (Upward), Stations: 10 Stations, SUP, EXH Block Mounting: D (D Side 1~10 Stations), Pilot Specification: S (Internal Pilot w/Built-in Silencer), SUP, EXH Block Fitting Spec: Straight Fitting, DIN Rail Length Specified: 10 Stations
Series: 1 (10-SV1000), Base Type: 10, Connector Type: PG (Flat Ribbon Cable Connector: 20 Pins), Connector Entry Direction: 1 (Upward), Valve Stations: 06 (6 Stations), P, E Port Location: D (D Side, 2-10 Stations), Pilot Type: Internal Pilot, A, B Port Size: C6 (One-touch Fitting for Ø6), Mounting: D (DIN Rail Mounting w/DIN Rail)