SMC Corporation of America
Elite Part Number Search
Search Results "VVEX4-1-5-AN"

Controls air pressure in proportion to an electric signal; Available in MPa, kgf/cm², bar, PSI, and kPa units; Pressure range of -80kPa to 0.9MPa; Available port sizes 1/4, 3/8 and 1/2; Mounting bracket option; Made to order options available for expanded features, including analog 4-20mA sourcing type, manifold mountable, high speed response, and others

Controls air pressure in proportion to an electric signal; Available in MPa, kgf/cm², bar, PSI, and kPa units; Pressure range of -80kPa to 0.9MPa; Available port sizes 1/4, 3/8 and 1/2; Mounting bracket option; Made to order options available for expanded features, including analog 4-20mA sourcing type, manifold mountable, high speed response, and others.

Great value for vacuum sensing in wet or dry environments, with an IP65 rating; 3 setting modes: 3-step, simple, function selection; 7 displayable units: MPa, kPa, kgf/cm2, bar, psi, inHg, mmHg; 2 switch outputs (NPN or PNP) plus 1 analog output (V or mA); Port sizes: M5 (female), 1/8 Rc or NPT (male), One-touch fitting (straight, elbow) (ø4 or 6mm, ø1/4"); Bracket or panel mounting options

Great value for vacuum sensing in wet or dry environments, with an IP65 rating; 3 setting modes: 3-step, simple, function selection; 7 displayable units: MPa, kPa, kgf/cm2, bar, psi, inHg, mmHg; 2 switch outputs (NPN or PNP) plus 1 analog output (V or mA); Port sizes: M5 (female), 1/8 Rc or NPT (male), One-touch fitting (straight, elbow) (ø4 or 6mm, ø1/4"); Bracket or panel mounting options

Monitor output is available as an analog or switch signal. ITV regulators are IP65 equivalent. Flows up to 4400 L/min; Aproximately 19% lighter than the legacy ITV series; Controls air pressure in proportion to an electric signal; Available in MPa, kgf/cm², bar, PSI, and kPa units; Pressure range of 0.005 to 0.9MPa; Available port sizes 1/4, 3/8 and 1/2; Mounting bracket option

PSE540 is UL/CSA, CE and RoHS compliant, with an IP40 enclosure. Smallest remote pressure sensor from SMC, for the most compact applications; Power supply requirement: 12 to 24 VDC; IO-Link or NPN / PNP open collector output; 2 Accuracy options: ±1% or ±2% of F.S.; Repeatability: ±0.2% of F.S.; Port sizes: M3, M5, 1/8 Rc or NPT male; M5 female; ø4 or ø6mm plug for fittings

Controls air pressure in proportion to an electric signal; Available in MPa, kgf/cm², bar, PSI, and kPa units; Pressure range of 0.005 to 0.9MPa; Available port sizes 1/4, 3/8 and 1/2; Mounting bracket option; Series for 25A-ITV is compatible with secondary battery applications

Great value for vacuum sensing in wet or dry environments, with an IP65 rating; 3 setting modes: 3-step, simple, function selection; 7 displayable units: MPa, kPa, kgf/cm2, bar, psi, inHg, mmHg; 2 switch outputs (NPN or PNP) plus 1 analog output (V or mA); Port sizes: M5 (female), 1/8 Rc or NPT (male), One-touch fitting (straight, elbow) (ø4 or 6mm, ø1/4"); Bracket or panel mounting options

Controls air pressure in proportion to an electric signal; Available in MPa, kgf/cm², bar, PSI, and kPa units; Pressure range of 0.005 to 0.9MPa; Available port sizes 1/4, 3/8 and 1/2; Mounting bracket option; Made to order options available for expanded features, including analog 4-20mA sourcing type, manifold mountable, high speed response, and others

Yes, it can be changed. Remove the adjustment bolts and replace them with the shock absorbers listed in the “Specifications” section in the catalog.
Keep the hexagon nut and seal washer, as they will also be used with the internal shock absorbers.
Precautions:
① Make sure it is known that the product specifications have been changed from those indicated by the part number on the

IO-Link enabled sensor for wet or dry environments, with an IP65 rating; 3 setting modes: 3-step, simple, function selection; 7 displayable units: MPa, kPa, kgf/cm2, bar, psi, inHg, mmHg; IO-Link mode: 16-bit digital process data; SIO mode: 1 switch output (selectable NPN or PNP); Port sizes: M5 (female), 1/8 Rc (male), 1/8 NPT (male); Bracket or panel mounting options

Flow ranges (lpm): 0.2-10, 0.5-25, 1-50, 2-100 (selectable from PFM5 ranges); Analog input, sensor (DC): 1-5V or 4-20mA; Analog output (DC): 1-5V or 4-20mA; Switch output modes: Hysteresis, window comparator, accumulation set point, accumulation pulse; Display accuracy: ±0.5% F.S.; Analog output accuracy: ±0.3% F.S.

This component is available individually as an additional nozzle to expand an existing system, or as a replacement.  A complete system consists of 1 to 4 nozzles, an IZTP power supply module for each nozzle, and a single IZTC controller, plus cables and accessories as required. 

Flow ranges (lpm): 0.2-10, 0.5-25, 1-50, 2-100 (selectable from PFM5 ranges); Analog input, sensor (DC): 1-5V or 4-20mA; Analog output (DC): 1-5V or 4-20mA; Switch output modes: Hysteresis, window comparator, accumulation set point, accumulation pulse; Display accuracy: ±0.5% F.S.; Analog output accuracy: ±0.3% F.S.

Flow ranges (lpm): 0-0.5, 0-1.0, 0-3.0, -0.5-0.5, -1.0-1.0, -3.0-3.0 (selectable from PFMV5); Analog input, sensor (DC): 1-5V; Analog output, monitor (DC): 1-5V or 4-20mA; Switch output modes: Hysteresis, window comparator, accumulation set point, accumulation pulse; Display accuracy: ±0.5% F.S.; Analog output accuracy: ±1% F.S.

Flow ranges (lpm): 0.2-10, 0.5-25, 1-50, 2-100 (selectable from PFM5 ranges); Analog input, sensor (DC): 1-5V or 4-20mA; Analog output (DC): 1-5V or 4-20mA; Switch output modes: Hysteresis, window comparator, accumulation set point, accumulation pulse; Display accuracy: ±0.5% F.S.; Analog output accuracy: ±0.3% F.S.

IO-Link enabled sensor for wet or dry environments, with an IP65 rating; 3 setting modes: 3-step, simple, function selection; 7 displayable units: MPa, kPa, kgf/cm2, bar, psi, inHg, mmHg; IO-Link mode: 16-bit digital process data; SIO mode: 1 switch output (selectable NPN or PNP); Port sizes: M5 (female), 1/8 Rc (male), 1/8 NPT (male); Bracket or panel mounting options

This component is available individually as an additional nozzle to expand an existing system, or as a replacement.  A complete system consists of 1 to 4 nozzles, an IZTP power supply module for each nozzle, and a single IZTC controller, plus cables and accessories as required.