Valve; w/Stop Valve), Return Port Size: 04 (1/2), Flow Switch Output Specifications: FT (Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Flow Switch Unit Specifications: F (Integrated Display: gal/min; Accumulated Flow: gal; Temp.: °F)
Model Type: Standard, Piping: F (Direct), Port Size: 10 [1" (25A)], Port Thread: F (G), Silencer: w/o Silencer, Pilot Port Size: 1 (1/8")
Size: 2 (Series 20), Valve Operation Type: 1 (Normally Closed), Valve Type: Nil (Standard), Body Material: S (Stainless Steel), Seal Material: F (FKM), Orifice Diameter/Port Size: 302 (Orifice Diameter: ø3.2mm; Port Size: 1/4), Thread Type: F (G), Rated Voltage: 5 (24 VDC), Electrical Entry: WN (M12 Connector/without Connector Cable; with Surge Voltage Suppressor)
Size: 2 (Series 20), Valve Operation Type: 1 (Normally Closed), Valve Type: Nil (Standard), Body Material: C (Brass), Seal Material: F (FKM), Orifice Diameter/Port Size: 302 (Orifice Diameter: ø3.2mm; Port Size: 1/4), Thread Type: F (G), Rated Voltage: 5 (24 VDC), Electrical Entry: WN (M12 Connector/without Connector Cable; with Surge Voltage Suppressor)
Size: 2 (Series 20), Valve Operation Type: 1 (Normally Closed), Valve Type: Nil (Standard), Body Material: C (Brass), Seal Material: F (FKM), Orifice Diameter/Port Size: 302 (Orifice Diameter: ø3.2mm; Port Size: 1/4), Thread Type: F (G), Rated Voltage: 5 (24 VDC), Electrical Entry: DZ (DIN Terminal w/Light, w/Surge Voltage Suppressor)
Series: NCA1 (Standard), Mounting: F (MF1, Front Flange), Bore Size: 400 (4"), Stroke: 0200 (2"), Air Cushion / Rod Boot: Both Ends (Air Cushion), Thread: F (Flanged), Adjustment Range: Not Applicable, Auto Switch: No Switch, Lead Wire or Prewired Connector: M (1m), Number: 2 pcs. (Or None in the Case of No Switch), X Option: XC6 (Piston Rod and Rod End Nut SUS304)
Stations: 5 Stations, AB Port: 04L (1/2, Left), Thread: F (G), Control: None, PR Port: 04B (1/2, Both Sides), PR Thread: F (G)
Series: NCA1 (Standard), Mounting: F (MF1, Front Flange), Bore Size: 500 (5" - Large Bore), Stroke: 0200 (2"), Air Cushion / Rod Boot: Both Ends (Air Cushion), Thread: F (Flanged), Adjustment Range: Not Applicable, Auto Switch: No Switch, Lead Wire or Prewired Connector: M (1m), Number: 2 pcs. (Or None in the Case of No Switch), X Option: XC6 (Piston Rod and Rod End Nut SUS304)
Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 04 (1/2), Output Specification: D (OUT1: NPN; OUT2: Analog 4 to 20mA), Temperature Sensor: None, Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: F (Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °F)
Compressor Output 30HP, (22kW)], Thread: F [G (Conforms to ISO1179-1)], Port Size: 06 (3/4), Accessory: B (Bracket), Auto Drain: Drain Cock w/o Auto Drain, Rubber Material: F (Fluororubber)
Compressor Output 30HP, (22kW)], Thread: F [G (Conforms to ISO1179-1)], Port Size: 06 (3/4), Accessory: None, Auto Drain: Drain Cock w/o Auto Drain, Rubber Material: F (Fluororubber)
Magnet: None, Mounting: F (Rod Flange), Bore Size: 32mm, Stroke: 50mm, Rod End Thread: F (Female Thread)
Valve: None; Stop Valve: None, Return Port Size: 03 (3/8), Flow Switch Output Specifications: ET (Out 1: PNP; Out 2: Flow Rate: Analog 1 to 5 V ⇔ Analog 1 to 5 V; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Flow Switch Unit Specifications: F (Integrated Display: gal/min; Accumulated Flow: gal; Temp.: °F)
Rated Flow Range: 40 (5 to 40 L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 04 (1/2), Output Specification: E (OUT1: PNP; OUT2: Analog 1 to 5V), Temperature Sensor: None, Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: F (Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °F), Bracket: R (Bracket), Calibration Certificate: A (Calibration Certificate
Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: DT (Out 1: NPN; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Return Unit Flow Switch Unit Specifications: F (Integrated Display: gal/min; Accumulated Flow: gal; Temp.: °F)
Magnet: D (Built-in Magnet), Mounting: F (Rod Flange), Bore Size: 32mm, Stroke: 25mm, Action: T (Single Acting, Spring Extend), Thread: F (Female Rod End), Pivot Bracket: None, Rod End Bracket: None, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: L (3m)
(Or None in the Case of No Switch), X Option: XB6 [Heat Resistant Cylinder, up to 300°F (150°C)]
Rated Distance Range: F (0.01 to 0.03mm), Piping Specifications: F (Supply Side: G 1/8, Detection Side: G 1/8), Output Specifications: P (PNP Output), Unit Specification: M (Fixed SI Unit), Stations: 4, Cable Option: Straight, Bracket Option: B (Bracket), Control Unit: L3 (w/Control Unit, Supply Port: Left Side, With regulator, Round type pressure gauge; 0.2 MPa)
Rated Flow Range: 21 (50 to 250 L/min), Flow Adjustment Valve: None, Thread: Rc, Port Size: 14 (1 1/2), Output Specification: K (OUT 1: Analog 4 to 20mA; OUT 2: Analog 4 to 20mA), Temperature Sensor: T (Temperature Sensor), Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: F (Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °F)
Rated Flow Range: 202 (20 to 2000 L/min), Thread Type: F (G), Port Size: 06 (3/4), Output Specifications: F (Out 1: PNP; Out 2: Analog 4 to 20 mA), Option 1: w/Lead Wire and M8 Connector, 3m, Unit Specification: Unit Selection Function, Option 2: No Bracket, Calibration Certificate: A (Yes)