Action D B T Port thread type Double acting Double acting with spring loaded Single acting (Spring extend) 20 to 50 Nil TN TF Rc NPT G Note) TF for 20 indicates M5.
ASN How to Order AQ ASN2 03 ASV JIS Symbol AK Option Nil S None With seal ASS Port size ASR M5 U10/32 01 02 03 04 M5 x 0.8 10-32 UNF 1/8 1/4 3/8 1/2 ASF Thread type Metric thread (M5) Unified thread (10-32 UNF) R NPT Nil N Needle Valve/Flow Characteristics Inlet pressure: 0.5 MPa Flow rate (l/min (ANR)) Effective area (mm2) Number of needle rotations 15-11-1 2 Series ASN Construction Component
Cylinder port size C3 C4 C6 M5 CM L3 L4 L6 L5 B3 B4 B6 B5 LM With 3.2 One-touch fitting With 4 One-touch fitting With 6 One-touch fitting M5 thread Mixed sizes and with port plug Top ported elbow Wtih 3.2 One-touch fitting Top ported elbow With 4 One-touch fitting Top ported elbow With 6 One-touch fitting M5 thread Bottom ported elbow With 3.2 One-touch fitting Bottom ported elbow With 4
x 0.8 M5 x 0.8 M3 x 0.8 Note) Only for external pilot Flow Characteristics Flow characteristics Port size 1R2 (PRA) 2R3 (ARR) Manifold C [dm3/(sbar)] 1(P), 3(R) port 2(A) port b Cv C [dm3/(sbar)] b Cv Type SS3YJ7-20 1/8 2.2 2.2 2.1 2.2 2.0 1.6 2.1 0.34 0.39 0.35 0.35 0.27 0.32 0.24 0.55 0.59 0.59 0.59 0.47 0.39 0.51 2.3 2.4 2.3 2.4 2.2 2.2 2.3 0.27 0.32 0.27 0.36 0.32 0.27 0.31 1/8 1/4 1
C4 C6 M5 L4 L6 B4 B6 4 One-touch fitting 6 One-touch fitting The "" symbol indicates mounting. Put the "" symbol at the beginning of part numbers for solenoid valves, etc., which are to be mounted. M5 x 0.5 4 elbow fitting assembly (upward) Valve stations are numbered from station 1 on the D side.
Model GS40-M5 GS40-01 GS40-02 AV Air/Inert gas Fluid AU 3% F.S.
Q H 05 1 3 5 ZM JIS Symbol Air supply port Exhaust port Vacuum port Port size connection Nozzle diameter 05 07 0.5 mm 0.7 mm 3 5 M5 x 0.8 M3 x 0.5 Specifications Ejector System Circuit 10 1.0 mm 13 1.3 mm Applicable nozzle size (mm) Supply valve P Q Supply valve and release valve 0.5, 0.7, 1.0, 1.3 Air operated valve H M 0.35 MPa 0.5 MPa Supply pressure Components Port size M3 x 0.5 M5 x
AIR SUP (P1) Rc, NPT, G 1/8" (12.7) 119 106 13 79 39 14 FLUID IN 1/2" tube extension AIR SUP (P2) Rc, NPT, G 1/8" 59 110 Foot (Option) 611 PAF Series Dimensions: Air Operated Type (PAF3000 Series) With nut (with LQ1 fittings): PAF3413S-1S13 1S19 152 2 x M5 x 0.8 Thread depth 9 139 114 116 95 19 4 x 7 Bottom view of body FLUID OUT AIR SUP (P1) Rc, NPT, G 1/8" With nut 119 106 13 79 39 14
Please contact us for the latest version.sales@ocaire.com, VALVE, SGL SOL, BODY PT (DC), VALVE, VQ1000/VQ20/VQ30 VALVE, BD, VQ1000 BODY PORT (M5), .17482 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, VALVE, SOL, BASE MT (DC), VALVE, SYJ300 SOLENOID VALVE 3-PORT, 2B, SYJ300 OTHER SIZE RATING, .16168 lb
Please contact us for the latest version.sales@ocaire.com, VALVE, SOL, BODY PT (DC), VALVE, SYJ500 SOLENOID VALVE 3/PORT, BA, SYJ500 BODY PORT M5, .11023 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, VALVE, SOL, BASE MT (DC), VALVE, SYJ300 SOLENOID VALVE 3-PORT, 2A, SYJ300 OTHER SIZE RATING, .13227 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, VALVE, SOL, BASE MT (DC), VALVE, SYJ300 SOLENOID VALVE 3-PORT, 2B, SYJ300 OTHER SIZE RATING, .14530 lb
Please contact us for the latest version.sales@ocaire.com, VALVE SOLENOID BODY PORTED, VALVE, VZ200 SOL VALVE 3-PORT, BA, VZ200 BODY PT(M5, NON-US STD), .19841 lb
VQD1000 series 4 port, direct operated, poppet solenoid valve offers large flow capacity in a compact, lightweight body. Vacuum applications (up to -100kPa) are possible. Components of the VQD1000 valves that are in contact with fluid are all copper free. The VQD series offers a remarkably quick and stable response time. Fluid: Air/inert gas , Operating pressure range: 0MPa/10Torr (Vacuum
VQD1000 series 4 port, direct operated, poppet solenoid valve offers large flow capacity in a compact, lightweight body. Vacuum applications (up to -100kPa) are possible. Components of the VQD1000 valves that are in contact with fluid are all copper free. The VQD series offers a remarkably quick and stable response time. Fluid: Air/inert gas , Operating pressure range: 0MPa/10Torr (Vacuum
VQD1000 series 4 port, direct operated, poppet solenoid valve offers large flow capacity in a compact, lightweight body. Vacuum applications (up to -100kPa) are possible. Components of the VQD1000 valves that are in contact with fluid are all copper free. The VQD series offers a remarkably quick and stable response time. Fluid: Air/inert gas , Operating pressure range: 0MPa/10Torr (Vacuum
VQD1000 series 4 port, direct operated, poppet solenoid valve offers large flow capacity in a compact, lightweight body. Vacuum applications (up to -100kPa) are possible. Components of the VQD1000 valves that are in contact with fluid are all copper free. The VQD series offers a remarkably quick and stable response time. Fluid: Air/inert gas , Operating pressure range: 0MPa/10Torr (Vacuum
Fluid: air , Operating pressure range (MPa): 0.15 to 0.7 , Ambient and fluid temperature: -10 to 50° C (no freezing) , Maximum operating frequency: 10Hz, VALVE, SOL, BODY PT (DC), VALVE, SYJ500 SOLENOID VALVE 3/PORT, BA, SYJ500 BODY PORT M5, .11358 lb
VQD1000 series 4 port, direct operated, poppet solenoid valve offers large flow capacity in a compact, lightweight body. Vacuum applications (up to -100kPa) are possible. Components of the VQD1000 valves that are in contact with fluid are all copper free. The VQD series offers a remarkably quick and stable response time. Fluid: Air/inert gas , Operating pressure range: 0MPa/10Torr (Vacuum