SMC Corporation of America
Elite Part Number Search
Search Results "CDLSF140TN-150"

characteristic measurement conditions 0 1.0 Exhaust flow rate of the vacuum pump used for measurement: 500l/min (ANR) 10 Set point Upstream vacuum pressure: 100kPa (when downstream flow rate is 0l/min (ANR)) 20 0.5 Output deviation (%F.S.) 30 Maximum flow rate: 132l/min (ANR) (with upstream VAC. pressure at 39kPa) Set pressure (kPa) 40 0 50 60 0.5 70 80 90 1.0 100 80 60 40 20 50 100 150

(mm) 10 9 8 7 6 5 4 3 Manifold stations n L1 L2 2 180 165 150 135 120 105 90 75 60 235.5 223 198 185.5 173 160.5 148 123 110.5 8

excessive impact, which may result in the damage to the devices. 6 10 Bore size (mm) 6 Operating piston speed (m/s) 0.05 to 0.5 L Allowable kinetic energy (J) 0.012 0.035 100 5st 10st 15st W 100 80 Load weight W (g) 10 10 60 6 Load weight (kg) L 40 1 W 20 0.1 00 5 10 15 20 0.01 0.01 1.0 0.1 Eccentric distance L (mm) Maximum speed (m/s) 10 300 5st 10st 15st 20st 250 Load weight W (g) 200 150

double 10 Max. operating frequency (Hz) 3 position 3 Body ported Manual override (Manual operation) Pilot exhaust method Non-locking push type, push-turn locking slotted type, push-turn locking lever type Individual exhaust for the pilot valve, common exhaust for the pilot and main valve Lubrication Mounting orientation Not required Unrestricted Note 2) Shock/Vibration resistance (m/s2) 150

Response time (ms) 2 position single,double 3 position P R R P R 2 Position double 2 Position double 2 position single,double 3 position B A B A Max. operating frequency (Hz) Manual override Pilot exhaust Lubrication Mounting position Impact / Vibration resistance (m/s2) Protection structure P R R P R Individual pilot exhaust type, common exhaust(pilot and main valve)type Not required Free 150

page 60.) 15 or less Max. operating frequency (Hz) 10 Non-locking push type, push-turn locking slotted type, push-turn locking lever type Manual override (Manual operation) Individual exhaust for the pilot valve, common exhaust for the pilot and main valve Pilot exhaust method Body ported Lubrication Mounting orientation Shock/Vibration resistance (m/s2) Note 2) Not required Unrestricted 150

pressure 0 0 0.5 1 1.5 2 2.5 3 3.5 4 4.5 5 Time sec Test circuit/Conditions P1 P2 Pump SRF30-m 2 Clean Room Regulator/Fluoro Resin Type Series SRF30 Flow-through Characteristics Particulate Generation Characteristics Particle concentration (particles/ml) Particle diameter: 0.1m or larger 400 1000 Value of specific resistance to that of supplied DI water 350 300 Resistivity (km) 100 250 200 150

position closed center 3 position 0.15MPa [21.75] 0.20MPa [29psi] (A) 4 (B) 2 Proof pressure 1.5MPa [217.5] 10 to 50C (14 to 122F) 5 to 50C (23 to 122F) Note 1) Note 1) Ambient and fluid temperature 1 (P) 5 (R1) 3 (R2) Lubrication Not required Manual override Non-locking push type/Slotted locking type (tool required) optional 3 position exhaust center (A) 4 (B) 2 Impact/Vibration resistance 150

For Air Upstream pressure of valve P1 1.0 MPa 1.0 Downstream pressure of valve (P2) MPa Downstream pressure of valve (P2) MPa 0.8 Subsonic Critical pressure 0.9 0.6 0.7 0.8 Sonic 0.4 0.6 0.5 0.4 0.2 0.3 0.2 0.1 0 VX211 VX22 VX23 VX2 4 VX2 5 VX2 60-02 VX2 602 50 100 150 200 250 300 350 3 100 200 300 400 500 600 4.5 200 400 600 800 1,000 1,200 3 2 3 2 3 2 3 2 03 04 6 500 1,000 1,250 8 500

specifications Coil Specifications Seal material FKM, EPDM Ambient temperature 20 to 100C (4 to 212F) Fluid temperature 99C or less (210F or less) Enclosure Dust proof, Splash proof (equivalent to IP65) Environment Location without corrosive or explosive gases Valve leakage 0cm/min (0in/min) (with water pressure) Mounting orientation Unrestricted Vibration/Impact resistance m/s Note 1) 30/150

Direct Operated 2 Port for Oil Dimensions (mm) (N.C.) 1in = 25.4mm W (44) Z (X) (V) T R (Y) T 25 IN port 2-3/8 l=280 l=300 2.5 (N) E A (U) S Q D G C C B L1 L2 L3 16 D side U side Stations 1 2 3 4 5 n 21 5.5 16 OUT port n-1/4 n-1/8 H H P=J (pitch) 2 : Thread type L dimensions (mm) n (stations) Model Dimension 2 3 4 6 9 7 5 8 10 L1 69 103.5 138 207 310.5 241.5 172.5 276 345 VV2CL2 L2 81 115.5 150

46.6 46.6 81 88 94 144 144 97 97 123 135 107.5 105.5 1 (P) 3 (R) 1 (P) 3 (R) 17 25 19 2 4-1/4,3/8,1/2NPT 4-3/4NPT VH42 -N06 (Bottom porting) VH42 -N02/N03/N04 (Bottom porting) 2 (A) 2 (A) 46 54 1 (P) 3 (R) 1 (P) 3 (R) 4 (B) 4 (B) 4-3/4NPT 4-1/4,3/8,1/2NPT 6 Body Mount/Dinensions Series VH (mm) / Body mount type Dimensions Scale: 35% VH600-N06/N10 2 (A) 4 (B) 1 (P) 132 152 411 132 300 223 150

pressure range Internal pilot type 5 to 50C Ambient and fluid temperature 25ms or less Response time (for 0.5MPa) Note 1) 5Hz Maximum operating frequency Non-locking push type, Slotted locking type Manual operation With vacuum pressure gauge Pilot valve individual exhaust type, Main valve/Pilot valve common exhaust Pilot exhaust type Not required Lubrication Unrestricted Mounting position 150

High purity fluororesin fitting , Space saving and tube connector type, Maximum operating pressure: 0.7MPa , Fluid temperature: 0 to 150 C , Variety of size combinations available LQ FITTING. FITTING, HIGH PURITY,TUBE CONN. CONNECTORS. LQ. .18717 lb. 22.

Standardized mounting options conform to both ISO 21287 and 6431.Conforms with the ISO 21287 standard, Bore sizes of 20, 25, 32, 40, 50, 63, 80 & 100 mm, Large stroke range from 5 mm up to 150 mm, Construction is similar to the current CQ2 lateral load resistant specification, Snap ring construction allows easy and quicker maintenance, Auto switches can be mounted on any of the four sides

Standardized mounting options conform to both ISO 21287 and 6431.Conforms with the ISO 21287 standard, Bore sizes of 20, 25, 32, 40, 50, 63, 80 & 100 mm, Large stroke range from 5 mm up to 150 mm, Construction is similar to the current CQ2 lateral load resistant specification, Snap ring construction allows easy and quicker maintenance, Auto switches can be mounted on any of the four sides

Standardized mounting options conform to both ISO 21287 and 6431.Conforms with the ISO 21287 standard, Bore sizes of 20, 25, 32, 40, 50, 63, 80 & 100 mm, Large stroke range from 5 mm up to 150 mm, Construction is similar to the current CQ2 lateral load resistant specification, Snap ring construction allows easy and quicker maintenance, Auto switches can be mounted on any of the four sides

Standardized mounting options conform to both ISO 21287 and 6431.Conforms with the ISO 21287 standard, Bore sizes of 20, 25, 32, 40, 50, 63, 80 & 100 mm, Large stroke range from 5 mm up to 150 mm, Construction is similar to the current CQ2 lateral load resistant specification, Snap ring construction allows easy and quicker maintenance, Auto switches can be mounted on any of the four sides

The multi-stage ZL series is a high-efficiency vacuum generator, which operates at 150% efficiency (compared to about 40% for other units). For each scfm of compressed air it consumes, the ZL generates an incredible 1.587 scfm of suction flow. The ZL is available with a built-in vacuum switch with digital readout for design flexibility.

The multi-stage ZL series is a high-efficiency vacuum generator, which operates at 150% efficiency (compared to about 40% for other units). For each scfm of compressed air it consumes, the ZL generates an incredible 1.587 scfm of suction flow. The ZL is available with a built-in vacuum switch with digital readout for design flexibility.