This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
Magnet: None, Mounting: D (Double Clevis), Bore Size: 50mm, Thread: TN (NPT), Stroke: 75mm, Body Option: M (Rod End Male Thread), Locking Direction: F (Forwarding Stroke Lock)
SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing p
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
Magnet: Built-in Magnet, Mounting: Both Ends Tapped, Bore Size: 50mm, Port Thread: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 75mm, Body Option: Rod End Male Thread, Auto Switch Groove: None (for 12-25 Bore w/o Magnet; 32-100 Bore w/o Magnet Z must be selected), Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: 3m, Number: 2 pcs. (Or None in
Magnet: Built-in Magnet, Mounting: Both Ends Tapped, Bore Size: 63mm, Port Thread: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 75mm, Body Option: Rod End Male Thread, Auto Switch Groove: None (for 12-25 Bore w/o Magnet; 32-100 Bore w/o Magnet Z must be selected), Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: 3m, Number: 2 pcs. (Or None in
Magnet: Built-in Magnet, Mounting: Both Ends Tapped, Bore Size: 80mm, Port Thread: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 75mm, Body Option: Rod End Male Thread, Auto Switch Groove: None (for 12-25 Bore w/o Magnet; 32-100 Bore w/o Magnet Z must be selected), Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: 3m, Number: 2 pcs. (Or None in
Magnet: Built-in Magnet, Mounting: Through-hole, Standard, Bore Size: 50mm, Port Thread: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 75mm, Body Option: Rod End Male Thread, Auto Switch Groove: None (for 12-25 Bore w/o Magnet; 32-100 Bore w/o Magnet Z must be selected), Auto Switch: A93V--Reed, DC Volt, AC Volt, LED, Vertical, Lead Wire or Prewired Connector: 3m, Number: 2 pcs. (Or None
Magnet: Built-in Magnet, Mounting: Through-hole, Standard, Bore Size: 80mm, Port Thread: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 75mm, Body Option: Rod End Male Thread, Auto Switch Groove: None (for 12-25 Bore w/o Magnet; 32-100 Bore w/o Magnet Z must be selected), Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: 3m, Number: 2 pcs. (Or None
Magnet: Built-in Magnet, Mounting: Through-hole, Standard, Bore Size: 32mm, Port Thread: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 75mm, Body Option: Rod End Male Thread, Auto Switch Groove: None (for 12-25 Bore w/o Magnet; 32-100 Bore w/o Magnet Z must be selected), Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: 3m, Number: 2 pcs. (Or None
Magnet: Built-in Magnet, Mounting: Through-hole, Standard, Bore Size: 50mm, Port Thread: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 75mm, Body Option: Rod End Male Thread, Auto Switch Groove: None (for 12-25 Bore w/o Magnet; 32-100 Bore w/o Magnet Z must be selected), Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: 3m, Number: 2 pcs. (Or None
Magnet: Built-in Magnet, Mounting: Double Clevis, Bore Size: 40mm, Port Thread: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 75mm, Body Option: Rod End Male Thread, Auto Switch Groove: None (for 12-25 Bore w/o Magnet; 32-100 Bore w/o Magnet Z must be selected), Auto Switch: F7NJ--Solid State, Heat Resistant, 2-color Indication, 3 Wire NPN, LED, Lead Wire or Prewired Connector: 3m, Number
Magnet: Built-in Magnet, Mounting: Through-hole, Standard, Bore Size: 63mm, Port Thread: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 75mm, Body Option: Rod End Male Thread, Auto Switch Groove: None (for 12-25 Bore w/o Magnet; 32-100 Bore w/o Magnet Z must be selected), Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: 3m, Number: 2 pcs. (Or None
Magnet: Built-in Magnet, Mounting: Through-hole, Standard, Bore Size: 63mm, Port Thread: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 75mm, Body Option: Rod End Male Thread, Auto Switch Groove: None (for 12-25 Bore w/o Magnet; 32-100 Bore w/o Magnet Z must be selected), Auto Switch: A93V--Reed, DC Volt, AC Volt, LED, Vertical, Lead Wire or Prewired Connector: 3m, Number: 2 pcs. (Or None