ISA2-G ISA2-H Detection side piping: 6 x 4 tubing 5 m Detection nozzle: 1.5 Standard pressure: 100 kPa Standard pressure: 100 kPa Detection side piping: 6 x 4 tubing 5 m Detection nozzle: 2.0 0.4 0.6 Standard pressure Standard pressure 0.5 mm 0.25 mm Detection distance (mm) Detection distance (mm) 0.5 0.3 0.4 0.2 0.3 0.15 mm 0.15 mm 0.2 0.1 0.1 0.03 mm 0.01 mm 0 0 50 0 250 200 150 100 250
4 x M8 I Minimum fluid level 6 x M8 135 170 Minimum fluid level Body mounting: Cut-out processing of the window is required for the customers tank.
IDFB Corrected air flow capacity = 31 m3/h (0.83 x 0.83 x 0.92) = 48.9 m3/h Obtain the corrected air flow capacity from the following formula. Corrected air flow capacity = Air consumption (Correction factor A x B x C) IDH 3 ID Select the model. According to the corrected air flow capacity of 48.9 m3/h, the IDFA8E will be selected when the required output air pressure dew point is 3C.
L2 = 21 x m + 89.8 L1 = 10.5 x n + 45 Do not operate in an atmosphere containing flammable or explosive gases. Fire or an explosion can result. This product is not designed to be explosion proof. Default settings At the time of factory shipment, the product is in "Remote Control Mode" and set to "Enable DHCP".
Table 3.3-1 Power supply cable and earth leakage breaker (Recommended) Earth leakage breaker Terminal Power Recommended Cable Sensitivity block Model supply crimp Specifications Breaker of screw voltage terminal 1 size leakage diameter (A) current (mA) 4 cores x AWG10 HRL100-A-20 3-phase (4 cores x 5.5 mm2) R5.5-5 30 200V AC including (50Hz) ground M5 30 4 cores x 3-phase HRL200-A-20 40 AWG8
) M5 30 3-phase 4 cores x 460 to 480V AWG8 AC(60Hz) (4 cores x 8 mm2) HRL300-A-40 R8-5 40 including ground 1 Cable specifications are the examples when using the product at a continuous allowable operating temperature of 70 oC, with an operating voltage of 600 V and two kinds of plastic insulated wires at an ambient temperature of 30 oC.
(LEC) 13.1 (LEC) (LEC) (LEC) () () DRIVE ON(1) OUT05 DRIVE ON(1)OFF(0) DRIVE OFF(0) OUT05 IN05 INP ON(1)BUSY OFF(0) OUT05 OFF(0) DRIVE OUT05 OFF RESET ON No.0 DRIVE OFF(0) 45 - 13.2 (LEC) PLC PLC (LEC) CC-Link (LEC) (LEC) 30ms (LEC)30ms CC-Link IO (LEC) 30ms (LEC) 1) 4 () 4 X 30ms120ms [IO ] 2) 12 () 12 X 30ms360ms [IO ] 3) 12 ( 6 ) () 12 X 30ms6 X 30ms540ms [IO ] CC-Link
Bore d C B H NTJ-015A 10 16 8.1 9.2 7 8 3.2 4 M4 X 0.7 NTJ-010A M5 X 0.8 * Refer to p.1.3-12 for details of the mounting nut. (mm) ND NN Bore 10 16 A B C D F GA GB H MM NA NB S Z 0 0.022 0 0.022 15 12 14 4 8 8 5 28 M4 X 0.7 12.5 9.5 M8 X 1.0 46 74 75 8 15 18 20 5 8 8 5 28 M5 X 0.8 12.5 9.5 M10 X 1.0 47 10 Refer to p.1.3-8 to 1.3-10 for dimensions of each mounting bracket.
With auto switch Basic/CS1BQ (mm) Bore (mm) 125 140 160 Stroke range (mm) S A H AL ZZ lB lC D E F G J K KA M MM N P 1/ 2 to 1000 98 50 110 47 235 145 115 36 90 43 16 M14 X 1.5 15 31 27 M30 X 1.5 35 1/ 2 to 1000 98 50 110 47 235 161 128 36 90 43 16 M14 X 1.5 15 31 27 M30 X 1.5 35 3/ 4 256.5 to 1200 106 56 120 53 182 144 40 90 43 18.5 M16 X 1.5 17 36 30.5 M36 X 1.5 39 CS1BQ125SCS1125, #1 CS1BQ140SCS1140
Description POM Valve 19033 19014 19024 e Stainless steel Spring 19037 19015 19025 r NBR O-ring 20 x 17 x 1.5 t NBR Ring 19016 19026 y Brass, NBR Seat ring 19013 19023 u Dimensions Model Port size L1 H B AK2000-01/02 22 25 1/8, 1/4 50 AK4000-02/03/04 36 36 1/4, 3/8, 1/2 67 AK6000-06/10 50 50 3/4, 1 95 Caution Be sure to read before handling.
Molecular structure Basic molecular structures Rubber type Basic molecular structure (-CH2-CH=CH-CH2-)x (-CH2-CH-)y I CN NBR (acrylonitrile-butadiene rubber) (-CH2-CH2-CH2-CH2-)x (-CH2-CH-)y I CN HNBR (hydrogenated nitrile butadiene rubber) Double bond Deterioration caused by ozone occurs when ozone acts on the NBR double bond to break the rubber molecules apart.
Features 1 Compact Cylinder Double Acting, Single Rod Bore size: 056 (9/16), 075 (3/4), 106 (1-1/16), 150 (1-1/2), 200 (2), 250 (2-1/2) Series NCQ8 How to Order Without auto switch B 056 025 NCQ8 B 056 025 Z M9B S NCDQ8 With auto switch X-Option Built-in magnet Nil XB6 XC4 Standard High temp.
A Mounting screws (M3 x 8L) (accessory) Waterproof seal (accessory) Panel mount adapter Power supply/Output connection cable ZS-26-A Panel Front protective cover + Panel mount B Mounting screws (M3 x 8L) Front protective cover (accessory) Waterproof seal (accessory) Panel mount adapter Panel Options When only optional parts are required, order with the part numbers listed below.
Load Load Switch 1 Blue [Black] Switch 1 + + Blue [Black] Brown [Red] Brown [Red] Switch 2 Switch 2 Blue [Black] Blue [Black] Load voltage at ON = Power supply voltage Residual voltage x 2 pcs. = 24V 4V x 2 pcs. = 16V Load voltage at OFF = Leakage current x 2 pcs. x Load impedance = 1mA x 2pcs. = 3k = 6V Example: Power supply voltage is 24VDC. Internal voltage drop in switch is 4V.
How to Order JT 20 Size Applicable cylinder Nominal thread size 20 For 20 M8 x 1.25 32 For 25 M10 x 1.25 For 32 M10 x 1.25 40 For 40 M14 x 1.5 Operating Conditions Operating pressure Pneumatic cylinder: 0.7 MPa or less Mounting Basic Operating temperature 10 to 70C 2
Brown Brown Load Load Switch 1 Switch 1 Blue Blue Brown Brown Switch 2 Switch 2 Blue Blue Leakage current Load Impendance x 2 pcs. x Power supply voltage Residual voltage x 2 pcs.
Output specifications 2CH X 2 outputs Number of outputs Pressure display range 101 to 10kPa (For vacuum), 10 to 100kPa (For low press.), 0.1 to 1MPa (For high press.)
+|TV205O-212S-X26 . . ... .1 set (Electro-pneumalic regulator pad no-)Nole2) LThe x is the symbol for mounting. Add the x symbol at the beginning of parl numbers lor electro-pneumalic regulators, etc. to be mounted on the base.
FMW-4200-X-30-FM-P85 30 Hg, Flush Mount, Polysulfone 1/8" ID Barbed Fitting FMW-4200-X-30-FM-OT1 30 Hg, Flush Mount, 1/8" O.D.
Fittings & Tubing Air Cylinders Rotary Actuators ISE35 N 25 M L A Digital Pressure Switch Construction Description Symbol Lock pin M3 x 0.5 x 7 (Aluminum materials screw) N Wiring bottom entry Digital pressure switch (Body only) Electrical entry R Adapter Wiring top entry O-ring Example) Regulator Wiring bottom entry O-ring + Wiring top entry Digital pressure switch (Body only) 25 65 NPN