Flow Switch Type: 7 (Integrated Display), Rated Flow Range: 04 (0.5~4L/min), Return Unit: W (Flow Adjustment Valve + Stop Valve), Thread: Rc, Port Size: 03 (3/8), Flow Switch Output: AT (Integrated Display; Out 1: NPN; Out 2: (NPN) ⇔ NPN ; Temperature Sensor: Yes), Lead Wire: with Lead Wire with M8 Connector (3m), Flow Switch Unit: M (Integrated Display, IO-Link Campatible; Instantaneous
Flow Switch Type: 7 (Integrated Display), Rated Flow Range: 20 (2~16L/min), Return Unit: None, Thread: N (NPT), Port Size: 04 (1/2), Flow Switch Output: FT (Integrated Display; Out 1: PNP; Out 2: (Analog 4 to 20 mA) ⇔ Analog 4 to 20 mA ; Temperature Sensor: Yes), Lead Wire: with Lead Wire with M8 Connector (3m), Flow Switch Unit: M (Integrated Display, IO-Link Campatible; Instantaneous
Switch Type: 7 (Integrated Display), Rated Flow Range: 20 (2~16L/min), Return Unit: W (Flow Adjustment Valve + Stop Valve), Thread: N (NPT), Port Size: 03 (3/8), Flow Switch Output: L2T (Integrated Display IO-Link Compatible; Out 1: IO-Link/Switch Output (N/P); Out 2: Switch Output (N/P) ; Temperature Sensor: Yes), Lead Wire: Q [with M12-M8 conversion Lead Wire (0.1m)], Flow Switch Unit: M
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, MINIATURE NON-LUBE, ACTUATOR, MCN ROUND BODY CYLINDER, HE, 20MM MCN DBL-ACT AUTO-SW, 4.62970 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
The rod is strongly in contact with the bushing by the eccentric load or lateral load, causing scratch. 4) A part of the rod is scratched in a direction perpendicular to the cylinder operation. A large lateral load is applied when the cylinder stops. 5) Air leaks from the rod seal. Scratch, dent, eccentric load, or external foreign object (solid or liquid) may be the cause.
A lateral load exceeding an allowable level is applied. The kinetic energy exceeds an allowable level. An excessive force is applied when mounting a load. The air leaks (seal is worn-out). Replace the seal. The following may be the cause of the trouble. The center between the cylinder and load deviates. A lateral load exceeding an allowable level is applied.
Series: 25A-PFM7, Flow Rate Range: 11 [2 to 100 (50) L/min], Port Size: N02 (NPT1/4), Piping Entry Direction: Straight, Output Specification: D [1 NPN Outputs + Analog (4 to 20 mA)], Unit Specification: M (Fixed SI Unit), Operation Manual: With Instruction Manual, Calibration Certificate: None, Connector: W (Lead Wire w/Connector, 2 m; Rubber Cover for Connector, Silicon Rubber)
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, MINIATURE NON-LUBE, ACTUATOR, MCN ROUND BODY CYLINDER, HE, 20MM MCN DBL-ACT AUTO-SW, 2.42508 lb
Part Number Description: MANOMETER Product Line: E Product Line Description: AIRLINE EQUIPMENT Family Code: 115 Family Description: AR REGULATOR Class Code: 22 Part Code: 2 Reference Code: B PDF Documentation: Datasheet Click here to report information errorImage shown may not match exact part number
Part Number Description: MANOMETER Product Line: E Product Line Description: AIRLINE EQUIPMENT Family Code: 115 Family Description: AR REGULATOR Class Code: 22 Part Code: 2 Reference Code: B PDF Documentation: Datasheet Click here to report information errorImage shown may not match exact part number
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, "FLOW SENSOR, LFK, DIGITAL FLOW SWITCH, N lb
Series: 25A-ISE20, Rated Pressure Range: A (-0.1 to 1 MPa), Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: M (SI Unit Only), Piping Specification: M5 (Female Thread), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire)
Series: 25A-ZSE20, Rated Pressure Range: AF (-100 to 100 kPa), Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: M (SI Unit Only), Piping Specification: M5 (Female Thread), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire)
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
Series M and MS miniature fittings are for use with air connections in confined areas. The hose nipple and hose elbow styles accept nylon, soft nylon and polyurethane tubing. The body of the MS series is stainless steel, making it possible to use this fitting in corrosive applications. Gasket and plug for M/MS miniature fittings; Available for series M3, M5 and MS5
Series: 5 (VP500), Body: 4 (Base Mounted), Pilot: R (External Pilot), Voltage: 5 (24 VDC), Electrical Enty: D (DIN Terminal), Light/Surge Suppressor: Z (w/Light/Surge Voltage Suppressor), Port Size: 03 (3/8"), Thread: Rc, Safety Limit Switch/Wiring: M (M12 Connector, Made by OMRON), with Check Valve, External Pilot Only: Check Valve: None; Applicable Tube: None, Throttle: Variable Throttle
Series M and MS miniature fittings are for use with air connections in confined areas. The hose nipple and hose elbow styles accept nylon, soft nylon and polyurethane tubing. The body of the MS series is stainless steel, making it possible to use this fitting in corrosive applications. Gasket and plug for M/MS miniature fittings; Available for series M3, M5 and MS5
Series: 25A-PFM7, Flow Rate Range: 11 [2 to 100 (50) L/min], Port Size: C6 (ø6 One-touch Fitting), Piping Entry Direction: Straight, Output Specification: B (2 PNP Outputs), Unit Specification: M (Fixed SI Unit), Operation Manual: With Instruction Manual, Calibration Certificate: None, Connector: W (Lead Wire w/Connector, 2 m; Rubber Cover for Connector, Silicon Rubber)