at 40 mA) Current leakage 100 A or less at 24 VDC Indicator LED Red LED illuminates when turned ON.
Choice of output types: PNP, NPN How to Order D-M9PJ J M9 N L D Output specifications Lead wire length Symbol Specication L Between the sensor and amplier: 3 m, Amplier section: 3 m Symbol Specication N NPN output P PNP output Z Between the sensor and amplier: 5 m, Amplier section: 3 m D-M9NJ Dimensions [mm] Auto Switch Specications Indicator light D-M9NJ, D-M9PJ (With indicator light) Auto
The value of the minimum bending radius is measured at the temperature of 20C as shown in the figure above. 472 Hard Polyurethane Tubing/High Pressure Type TUH Series RoHS KQ2 Model/Specifications KQB2 20 m roll 100 m roll Model TUH1065 TUH0805 TUH0604 TUH0425 TUH1208 KS KX O.D. (mm) 10 8 6 4 12 I.D. (mm) 6.5 5 4 2.5 8 KM Bend the tube into U-form at a temperature of 20C.
(EX245-EA2-1) No. 1 SI ON/OFF 2 IO-Link IO-Link 3 4 5 SI 6 . 1-1 12 No.EX-OMW0014CN-A 2. . 2-1 EX245 DC24 V 1 msec IP65(,) (IEC 60529 ) CE/UKCA UL(CSA) RoHS EN505812012 AC500 V1 FE 10 M -FE DC500 V -1050 -2060 35%85%RH 1057 Hz0.75 mm p-p 57150 Hz49 m/s 2 XYZ 2 (IEC60068-2-6) 147 m/s 2 XYZ 3 () (IEC60068-2-27) 13 No.EX-OMW0014CN-A 3. 3.1. 6 2M5( = 1.5 Nm
When [M] is included in the controller model number the controller displays [S_J]. When [M] is not included in the controller model number the controller displays [S_F]. Hysteresis mode ON OFF Power on Specifications Outline with Dimensions (in mm) n_1 High pressure Wiring Normally closed mode Detects pressure displays values and performs switching.
100 A or less at 24 VDC Indicator LED Red LED illuminates when turned ON.
(coil temperature 20C, at rated voltage, without surge voltage suppressor) When equipped with DC solenoid/surge voltage suppressor, a delay of about 20 to 30msec occurs in the OFF response time.
Between external terminals and housing 2 M (500 VDC by megameter) 10 to 500 Hz Pulse width 1.5 mm or acceleration 98 m/s2 (at the smaller vibration) to X, Y, Z direction (2 hours) 980 m/s2 to X, Y, Z direction (3 times for each direction) PS Z I SE1 2 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800)
I Auto.manual (A/M ) selector When manual operation ot a diaphragm valve is required, turn the A/M slector in the M direction, and then the supply air pressure can directly be ted to the OUT I side, allowing the diaphragm valve to be operated by control of the pressure regulating valve in the supply pressure line.
Piston rod Movement at No Signal Operation (DIP Switch No.5, No.6) . 18 2-4. Maximum Piston Rod Speed Setting (Rotary Switch) . 19 3. Operation Example . 20 3.1 At first operation after purchase . 20 3.2 At the time of operation after the second time . 21 3 Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage.
Therefore, install the auto switch at the home position of the cylinder as much as possible. If the auto switch is not at the home position, a setting error will result, making it difficult to accomplish an optimal balance.
The tightening torque at the valve side depends on the valve type. Refer to the operation manual of the corresponding valve manifold.
100 A or less at 24 VDC Indicator LED Red LED illuminates when turned ON.
Impact/Vibration resistance m/s2 Note) 150/30 (8.3 to 2000Hz) Dust proof Enclosure Note) Impact resistance: No malfunction when tested with a drop tester in the axial direction and at a right angle to the main valve and armature, one time each in both energized and deenergized states.
(max. 20 stations) 3 SX3000 5 SX5000 Connector mounting position Symbol Mounting position U U side D D side Valve stations A, B port size Note Symbol 02 Stations SX3000 SX5000 2 stations Port size 4 One-touch fitting 6 One-touch fitting Mixed Symbol Port size 4 One-touch fitting 6 One-touch fitting 8 One-touch fitting Mixed Symbol C4 C6 M Double wiring specification C4 C6 C8 M 08 02 8 stations
FGDTF*-04 FGD-CV005-06 FGDTF*-06 (5) FGD-CV006-03 FGDCE*-03 FGD-CV006-04 FGDCE*-04 FGD-CV006-06 FGDCE*-06 FGD-OP001 FGD*B (10) KT-FGDC FGDC KT-FGDE FGDE (2)(4)(6)(13)(16) KT-FGDT FGDT KT-FGDF FGDF FGD-CA002 FGDT,F(L250) (7)(9)(11)(12)(13) (14)(15)(16)(17) FGD-CA003 FGDT,F(L500) L500 (18) FGD-CA004 FGDC,E(L250) FGD-CA005 FGDC,E(L500) 7/11 FGX-OM-L007-C 2. 2.
AS121FP-M5 AS221FP-01 AS221FP-02 Upstream pressure: 0.5 MPa Upstream pressure: 0.5 MPa Upstream pressure: 0.5 MPa Flow rate (L/min (ANR)) Flow rate (L/min (ANR)) Flow rate (L/min (ANR)) 08,10 06,08 06 04 04 Number of needle rotations Number of needle rotations Number of needle rotations AS321FP-03 AS421FP-04 Upstream pressure: 0.5 MPa Upstream pressure: 0.5 MPa 12 10 Flow rate (L/min (ANR
Lead wire length symbols: 0.5 m Nil (Example) M9NW Solid state auto switches marked with a are produced upon receipt of order. 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ For details on auto switches with pre-wired connectors, refer to the Web Catalog.
(M) 15D (M) 20D (M) 20D (M) 25D (M) 25D (M) 30D (M) 30D (M) 7 35D (M) 35D (M) 14.5 40D (M) 40D (M) 45D (M) 45D (M) 50D (M) 50D (M) 75D (M) 75D (M) 100D (M) 100D (M) CHQWB100 10D (M) CHQWB40 5D (M) 15D (M) 10D (M) 20D (M) 15D (M) 25D (M) 20D (M) 30D (M) 25D (M) 35D (M) 30D (M) 13.5 10 40D (M) 35D (M) 45D (M) 40D (M) 50D (M) 45D (M) 75D (M) 50D (M) 100D (M) 75D (M) 100D (M) CH QWB50 10D (M
2.39 (Nm) m Load factor = M/M max = 2.39/50 = 0.05 M Features 5 Model Selection Series MY1 Model Selection X M: Moment M max (from 3 of graph MY1H/M) = 38.7 (Nm) M = m x g x X = 6.525 x 9.8 x 138.5 x 10= 8.86 (Nm) m M Load factor = M/M max = 8.86/38.7 = 0.23 5 Calculation of load factor for dynamic moment Equivalent load FE at impact 1.4 100 1.4 100 FE = x a x g x m = x 300 x 9.8