Speed controller with one-touch fittings, Body sizes: M5, 01, 02, 03, 05, Metal body elbow style, Meter-in or meter-out control, Port sizes: M5, 01, 02, 03, 04, Tube O.D.: 04, 06, 08, 10, 12, FLOW CNTL METAL BODY W/FITTING, AIRLINE EQUIPMENT, AS FLOW CONTROL, AX, AS M5 (MISC./OTHER), .03472 lb
Speed controller with one-touch fittings, Body sizes: M5, 01, 02, 03, 05, Metal body elbow style, Meter-in or meter-out control, Port sizes: M5, 01, 02, 03, 04, Tube O.D.: 04, 06, 08, 10, 12, SPEED CONTROL, AIRLINE EQUIPMENT, AS FLOW CONTROL, AB, AS M5 STANDARD (PT), .03858 lb
Speed controller with one-touch fittings, Body sizes: M5, 01, 02, 03, 05, Metal body elbow style, Meter-in or meter-out control, Port sizes: M5, 01, 02, 03, 04, Tube O.D.: 04, 06, 08, 10, 12, SPD CNTRL METAL BODY W/FITTING, AIRLINE EQUIPMENT, AS FLOW CONTROL, AB, AS M5 STANDARD (PT), .02799 lb
Speed controller with one-touch fittings, Body sizes: M5, 01, 02, 03, 05, Metal body elbow style, Meter-in or meter-out control, Port sizes: M5, 01, 02, 03, 04, Tube O.D.: 04, 06, 08, 10, 12, SPD CNTRL METALBODY W/FITTING, AIRLINE EQUIPMENT, AS FLOW CONTROL, AX, AS M5 (MISC./OTHER), .03086 lb
set unit Note 1) Accumulated pulse flow rate exchange value (Pulse width: 50 ms) Note 1) 0.1 l/pulse 0.5 l/pulse 1 l/pulse 2 l/pulse 5 l/pulse l/min, CFM x 10-2 l, ft3 x 10-2 l/min, CFM x 10-1 l, ft3 x 10-1 Display units Real-time flow rate Accumulated flow Note 1, 2) 0 to 9 l, 0 to 9 ft3 x 10-2 0 to 9 l, 0 to 9 ft3 x 10-1 Accumulated flow range Note 1) Power supply voltage Current consumption
^-2 1: 10^-1 2: 10^0 3: 10^1 4: 10^2 5: 10^3 6: 10^4 7: 10^5 8: 10^6 AC_E_L (Setting L of the accumulated flow value conversion factor) Setting of the accumuated flow value conversion factor Unit specification (Unit): When "L" is selected. 1071 0x042F 0 R/W U8 2 Y 0: 10^-2 1: 10^-1 2: 10^0 3: 10^1 4: 10^2 5: 10^3 6: 10^4 7: 10^5 8: 10^6 Accumulated value setting AC_E_G (Setting G of the accumulated
0 90 Vacuum pressure reached 80 kPa Vacuum pressure in tank [kPa] 80 Vacuum pressure [kPa] 66 kPa 70 60 53 kPa 50 40 kPa 40 26 kPa 30 20 13 kPa 10 0 Suction flow rate [L/min (ANR)] 10 0 20 30 40 50 60 70 80 90 100 1 10 Time to reach vacuum [s] 1 0 2 3 4 5 6 7 8 9 10 11 12 Vacuum Break Flow Rate Characteristics*1 (Representative value) *1 Silencer exhaust specification The graph shows the
Symbol 100 200 500 50 10 Rc NPT G 01 02 03 04 1/8 1/4 3/8 1/2 PFA510, 550 PFA511, 521 PFA551 Specifications PFA511 PFA521 PFA551 PFA510 PFA550 Model Measured fluid Dry air, N2 Detection type Heater type 20 to 200l/min 50 to 500l/min 10 to 100l/min 1 to 10l/min 5 to 50l/min Flow rate measurement range Operating pressure range 0 to 0.5MPa Withstand pressure 1.0MPa 3kPa (at 50l/min) 3kPa
DC 586-3WMP J-1.6MM only) (Multi-Purpose) 19 10-32 Ports (Metal body only) plastic S-Extended PSI rates for 21 10-32 Ports metal S.S.(430F) bodies/housing only 22 10-32 Ports Brass 23 10-32 Ports S.S(303F) 24 10-32 spud mount S.S.(430F) 25 10-32 spud mount brass 26 10-32 spud mount S.S(303) 27 M5 ports S.S. (430F) 28 M5 ports brass 29 M5 ports S.S.(303) EXAMPLE G 120 60 58 3 AF 16 P Lead
70 0.01 2 40 6000 100 40 0.1 3 90 1000 20 1 4 10 +3 5 5 10 +7 6 0 < Cp 5 +10 7 5 < Cp 10 Cw 0.5 8 0.5 < Cw 5 9 5 < Cw 10 x Cp > 10 Cw > 10 > 5 [How to Perform a Test to Check the Performance] ISO 12500, which sets out the test method to be used in order to check the filter performance for each of the three kinds of contaminants, is indicated below.
ZS-40-M Taptite screw for PF3W711 (4 x 10), 4 pcs.
Applicable tube external DIA. 10 NPT3/8" 10 NPT3/8" 10 NPT3/8" Note 2 Option Semi-standard Semi-standard Port thread Part no. Rc G NPT AD47N-8(Z)-A AD47-8-A B External appearance drawing and part no. Applicable tube external DIA. 10 NPT3/8" 10 NPT3/8" 17 Note 2 Note 2 Option Semi-standard Semi-standard Semi-standard Part no. Part no.
Vacuum Pressure switch for vacuum with for compound pressure switch energy saving function pressure Rated pressure range [kPa] -101 to 0 -100 to 100 Set / display pressure range [MPa] -101 to 10 -105 to 105 Proof pressure [kPa] 500 Lowest configurable increment [kPa] 0.1 Applicable fluid Air, non-corrosive gas and non-flammable gas Power supply voltage: [VDC] 12 to 24 10%, ripple (p-p), 10%
Applicable tube external DIA. 10 NPT3/8" 10 NPT3/8" 10 NPT3/8" Note 2 Option Semi-standard Semi-standard Port thread Part no. Rc G NPT AD37N-8(Z)-A AD37-8-A B External appearance drawing and part no. Applicable tube external DIA. 10 NPT3/8" 10 NPT3/8" 14 Note 2 Note 2 Option Semi-standard Semi-standard Semi-standard Part no. Part no.
Specification for Option_H 10 1 Safety instructions . 10 1 10 2 Specification . 10 1 Chapter 11 Specification for OptionK 11 1 Safety instructions . 11 1 11 2 Specification . 11 1 Chapter 12 Specification for Option_L 12 1 Safety instructions . 12 1 12 2 Specification . 12 1 12 3 Installation . 12 2 12 4 Maintenance . 12 2 Chapter 13 Specification for Option_R 13 1 Safety instructions
The tightening torque of the mounting screw must be 0.45 Nm 10%. When the product is mounted using the bracket, fix with M5 screws (2 pcs.) or equivalent. The Bracket thickness is approx. 1.6 mm.
4 (mm size) KJH04-M5 06 6 (mm size) KJH06-M5 Specifications Model PPA100 for high press.
Note 2) Fixed unit For vacuum/compound pressure: kPa For positive pressure: MPa One-touch fitting type One-touch fitting None Applicable tubing material Applicable tubing size Symbol None None Nil Nylon Soft nylon Polyurethane 04 4 (mm size) KJH04-M5 06 6 (mm size) KJH06-M5 Specifications Model PPA100 for high press.