125 25 50 75 100 Courtesy of Steven Engineering, Inc. !

44.3 32.8 19 14 23 13.2 6 58 17 39.3 27.8 15.2 8 60 18.5 41 29.5 R 3/8 19.8 47.4 42.4 42.4 37.4 18.5 10 62 21 43.1 31.5 20.9 12 64 22 44.3 32.8 18.5 10 101 21 47.9 33.6 24 17 28.6 R 1/2 24.5 58.7 51.2 51.4 43.9 20.9 12 107 22 49.5 35.2 Note 1) Reference dimensions Note 2) Reference thread dimensions after installation. 606

Indicator light Operating Range [mm] Auto switch model Bore size 16 20 25 32 40 50 63 D-M9NJ D-M9PJ 4.5 4.5 4.5 5 4.5 5 5 22 64.5 4 Since the operating range is provided as a guideline at room temperature, it cannot be guaranteed. It may change substantially depending on the ambient environment.

When using auto switches, do not operate in an environment with strong magnetic fields. 22 Series MIW/MIS Specific Product Precautions 1 Be sure to read before handling. Refer to pages 16 through 18 for safety instructions, actuator precautions and auto switch precautions. Mounting Selection Handling of Adjuster Options 3.

29 0 38 40 31 105 93 66 1/4 47.5 23.5 65.5 6 M4 x 0.7 Depth 4.5 22 29 0 38 40 31 125 66 1/4 23.5 82.5 23 67.5 10.5 M4 x 0.7 Depth 4.5 22 29 0 38 40 31 125 66 1/4 23.5 84.5 27.5 M5 x 0.8 Depth 5 24 28 2 43 48 36 112 100 76 3/8 50.5 27.5 68.5 M5 x 0.8 Depth 5 24 28 2 43 48 36 132 76 3/8 27.5 85.5 16 70.5 3.5 M5 x 0.8 Depth 5 24 28 2 43 48 36 132 76 3/8 27.5 87.5 20.5

Delivery Pressure: 10 [2 to 100 psig (0.014 to 0.7 MPa)], Material: SH (Body: 316L SS Secondary Remelt; Poppet: Hastelloy® C-22; Diaphragm: Hastelloy® C-22; Nozzle: Hastelloy® C-22), Surface Finish: M [10 μin. (0.25 μm)], Ports: 4PW [4 Ports (1-In; 2-Out; 3-Gauge Port In; 4-Gauge Port Out)], Connections, Inlet: FV4 (1/4 Inch Face Seal, Female), Connections, Outlet: MV4 (1/4 Inch Face

Delivery Pressure: 10 [2 to 100 psig (0.014 to 0.7 MPa)], Material: SH (Body: 316L SS Secondary Remelt; Poppet: Hastelloy® C-22; Diaphragm: Hastelloy® C-22; Nozzle: Hastelloy® C-22), Surface Finish: 15 μin. (0.4 μm), Standard, Ports: 4PW [4 Ports (1-In; 2-Out; 3-Gauge Port In; 4-Gauge Port Out)], Connections, Inlet: MV4 (1/4 Inch Face Seal, Male), Connections, Outlet: FV4 (1/4 Inch Face

Delivery Pressure: 10 [2 to 100 psig (0.014 to 0.7 MPa)], Material: SH (Body: 316L SS Secondary Remelt; Poppet: Hastelloy® C-22; Diaphragm: Hastelloy® C-22; Nozzle: Hastelloy® C-22), Surface Finish: 15 μin. (0.4 μm), Standard, Ports: 3PW [3 Ports (1-In; 2-Out; 4-Gauge Port Out)], Connections, Inlet: FV4 (1/4 Inch Face Seal, Female), Connections, Outlet: FV4 (1/4 Inch Face Seal, Female

Delivery Pressure: 10 [2 to 100 psig (0.014 to 0.7 MPa)], Material: SH (Body: 316 SS; Poppet: Hastelloy® C-22; Diaphragm: Hastelloy® C-22; Nozzle: Hastelloy® C-22), Range Options: Standard, Ports: 5PC [5 Ports (1-In; 2-Out; 3-Extra Bottom Port Out; 4-Gauge Port In, 5-Gauge Port Out)], Connections, Inlet: 4 (NPT 1/4 Inch), Connections, Outlet: 4 (NPT 1/4 Inch), Gauge Port, Extra Bottom

(22) Nclise L.evel Construction/Dimensions (mm) 130 120 1 1 0 1()0 90 80 70 60 N2505 N2506 N?

Output indication mode [Output Ratio] Setting range : -100 to 100% Min. increment : 1% Indicated content: Thermo module output ratio (Ex.: -73%) Function: Indicates Thermo module output ratio with O u t p u t R a t i o M O D E < 7 3 % increment of 1%. + is not indicated but + means heating and means cooling. 11.Upper/Lower Temp.

P 500 150 144 400 104 100 300 P 66 43 26 16 90 200 50 56 34 22 14 8 5 100 0 0 20 30 40 50 60 70 80 90 100 10 20 30 40 50 60 70 80 90 100 10 Bore size (mm) Bore size (mm) 1.15-33 Series VY511/VYU5 Precautions Be sure to read before handling. Refer to p.0-26 and 0-27 for Safety Instruction and common precautions on the products mentioned in this catalog.

[L/min (ANR)] 06, 07, 08, 09, 10 06, 07, 08, 09, 10 01, 23, 03, 04, 06, 07 01, 23, 03, 04, 06, 07 08, 09, 10, 11 08, 09, 10, 11 03, 04 400 200 06, 07 02 01, 23 300 50 03, 04 200 100 01, 23 100 0 0 0 5 0 10 5 0 10 5 0 10 Number of needle rotations Number of needle rotations Number of needle rotations Note) -U10/32 has the same specification as M5.

Applicable Fluids Material and fluid compatibility check list for high purity fluoropolymer fittings Chemical Compatibility LVC Acetic acid 100% LVA Acetone 100% Note 1,2) LVH Ammonium fluoride 40% Ammonium hydroxide 30% LVD Butyl acetate 100% LVQ Methylne chloride 100% LVP Hydrochloric acid 38% LVW Hydrofluoric acid 50% LQ1 LQ1 Hydrogen peroxide 60% LQ3 LQ3 Methanol 100% LVN LVN

Without bracket (Bottom view) Bracket thickness is approx. 1.6mm Model Piping port size A B C D E F G H I J K L LFE13(Z) 3/8 90 73 40 23.5 56 83 89 24 6 1.6 96 87 LFE14(Z) 1/2 104 73 40 23.5 56 83 89 28 6 1.6 96 87 LFE26(Z) 3/4 105 78 50 29 67 94 100 35 6 1.6 115 106 LFE38(Z) 1 120 90 55 32 73 100 106 41 6 1.6 115 106 Model M N O P Q R S T U Bracket weight LFE13(Z) 48 39 4.6 12 11.5 52 28

ULUL1310Class2 6.2 2) AWG20(0.5mm (24V0V) 60 2) EMG AWG20(0.5mm (EMG+,EMG-) 60 8mm 21 - D (100) D 6.3 (CN2SW)ON (EMG+,EMG-) (LEC)EMG (CN2SW) RY CN4 CN2 EMG+ EMG24V 0V (CN2SW)ON EMG+,EMG-(LEC)OFF (LEC)(EMG+,EMG-) 22 - (LEC) ()LEC6 DC24V 0V Ry EMG+ Ry EMG(1 ) BK RLS EMG Ry C 24V 24V M 24V 0V 0V (2 ) BK RLS EMG Ry C 24V 24V M 24V 0V 0V (3 ) BK RLS EMG Ry C 24V 24V M

Table 1 100 Total operation cycles (10,000) 50 40 30 20 10 100 200 300 400 500 700 1000 Stroke (mm) Inner cover holding screw tightening torques [Nm] Tightening torque Model Screw size CYV15 0.3 M3 x 0.5 CYV32 2.45 M6 x 1 Plate Stroke adjustment screw (inner cover) Hexagon wrench Inner cover holding screw direction + direction 11 SMC'S GLOBAL MANUFACTURING, DISTRIBUTION AND SERVICE NETWORK

01 Nil Nil None Individual pilot exhaust Common pilot exhaust Z With light/surge voltage suppressor (Indicator light is not available for grommet type.) 2 Body ported Manual override Base mounted 5 Nil Push type (Safety style) Common pilot exhaust S With surge voltage suppressor (Grommet type) B Locking type (Tool required) Rated voltage C Locking type (Manual) DOZ is not available. 1 100

Model determination 2 Sine Rodless Cylinder Series REA Model Selection Method 2 Precautions on Design 1 Selection Method 40 32 25 500 500 300 200 300 400 Recommended driving force: Fn(N) 200 300 Recommended driving force: Fn(N) Recommended driving force: Fn(N) 200 100 100 100 50 40 20 30 40 50 20 30 40 50 20 30 Usable

Decrease of hydraulic oil + Replenished from the oil pocket Operating cycles Hydraulic oil amount 100% recovered Cylinders with RJ series For details, refer to page 1118.