D -With Built in Magnet (Not available as std. on single acting models, XB6 & XB7) I XBg -Low Friction I XCO -Stainless Steel Rod LNumber of Auto-swircnes -2 pcs. S 1 p c . n n p c s . L Long leads uountng B Front Nose Mount C -Rear Pivot E -Double End K -Non-Rotating Rod R -Block Mount W-Double Rod Auto.Switch 853. D-853 Gsg D-G59 B54. D-854 K59 D-K59 864 .
Rc 1/8 (Suction port) C B D F G E Element fixing nut N pcs. 4 x 5.5 drill 9.5 depth of counter bore 7 (mounting hole) A B C D E F G N Part no.
ECC-PNAL-20MT-D ECC-PNAL-20MR-D ECC-PNAL-20MR-A ECC-PNAL-10MT-D ECC-PNAL-10MR-D ECC-PNAL-10MR-A ECC-PNAL-6MR-A Please Note: 1) All PneuAlphas need to be connected to a power supply. 4/2 : 6/4 : 12/8 suitable to their rated voltage specifications. 2) Stand alone controllers can be programmed from the 8 front panel function keys. 3) All Pneu Alpha controllers have a CD-ROM supplied giving
(Nm) L(mm) MHM-16D M3x0.5 0.63 6 MHM-25D M4x0.7 1.5 8 MHM-32D M5x0.8 3 10 MHM-50D M6x1 5.2 12 (N) MHM-16D 100 MHM-25D 200 MHM-32D 300 MHM-50D 500 -7- 2-3. 40 2-4. () 5 5 P-01-11 -8- 2-5. 1.52 2-6. 1 ()ISO VG320 (SDS) -9- 2-7. 1) 1) 2) 3) 12mm -10- 2 C3 C1 C2: C3 D-M9V D-M9WV D-M9AV D-M9 D-M9W D-M9A D-P3DWA A B E G A B E G L A B E G L D F H MHM-16D 9.1 9.1 5.6 4.6 8.1 12.8 11
How to Order B 32 30 D C CQ2Y Standard B F9BW S 32 30 D C CDQ2Y With auto switch Number of auto switches With auto switch (Built-in magnet) 2 pcs. 1 pc. n pcs.
65 41 A 97 61 a 2 2 STX 34 22 " 66 42 B 98 62 b 3 3 ETX 35 23 # 67 43 C 99 63 c 4 4 EOT 36 24 $ 68 44 D 100 64 d 5 5 ENQ 37 25 % 69 45 E 101 65 e 6 6 ACK 38 26 & 70 46 F 102 66 f 7 7 BEL 39 27 ' 71 47 G 103 67 g 8 8 BS 40 28 ( 72 48 H 104 68 h 9 9 HT 41 29 ) 73 49 I 105 69 i 10 0A LF 42 2A * 74 4A J 106 6A j 11 0B VT 43 2B + 75 4B K 107 6B k 12 0C FF 44 2C , 76 4C L 108 6C l 13 0D CR 45 2D
Note Weight Bracket LFE-1-D Tapping screw for LFE1 (3 x 10), 4 pcs. Approx. 45 g LFE-2-D Tapping screw for LFE2 (3 x 10), 4 pcs. Approx. 70 g LFE-3-D Tapping screw for LFE3 (3 x 10), 4 pcs. Approx. 70 g 3 3-Color Display Electromagnetic Digital Flow Switch LFE Series For the flow switch precautions, refer to the Operation Manual on the SMC website.
BBA4: D-C7/C8/H7 "D-H7BAL" switch is set on the cylinder with the screws above when shipped.
For single power supply use COM D COM D is receiving data: Lights up 2 COM D is having no data to receive: Goes off 1: Refer to "Operation Manual" for the extension diagnosis information. 2: It is lit when input unit is connected and communicating normally.
Inch Size Applicable tubing O.D. d Applicable tubing O.D. d T D1 D2 D3 L1 L2 L3 M1 L4 (3) A (2) D1 D2 L1 L2 L3 L4 (3) A (2) Weight (g) H (1) Weight (g) H (1) T M1 Model Model Min.
500 1291 1070 670 325 282 Model A 8B B 380 380 450 C 1125 1125 1178 D 935 935 980 E 505 505 540 F 265 265 265 Port size AFF75A AFF125A AFF150A 3BJIS10k flange 4BJIS10k flange 2BJIS10k flange Drain Rc 3/8 N3 8B 10B 14-20-14
Signal Cable color S Standard cable Brown Red Orange Yellow Green Blue A A B B COM-A/COM COM-B/ 2 1 6 5 3 4 Cable color Connector D terminal no.
A B 63 63 80 85 90 100 C Port size Rc(PT) INA-11-402 INA-11-403 INA-11-404 INA-11-405 INA-11-406 INA-11-407 Model No. 1/4 15 15 15 20 22 22 141 164.5 170 180 230 251 3/8 1/4 , 3/8 , 1/2 3/4 B C D E F Port size Rc(PT) 3/4 , 1 1 Model No. A 1 2 150 165 42.7 76.3 45 65 40 60 35 40 80 80 ALBA90-10 ALBA90-20 1.17-24
Dimensions IN574-95 (Sensor head + Display part) 20 40 230 D-F8N (2 pcs.) 110 Red tape 500 20 M12 Connector Tube (3 places) Green tape Sensor head Wiring Terminal no. Description Note 1 +15 V 1 2 1 2 5 2 Output signal 1 D-F8N 3 4 3 4 Display part 3 GND Socket connector A-coded (Normal key) Plug connector A-coded (Normal key) 4 Output signal 2 D-F8N DD1677
Lube Unit/ALDU600-06 to 10, ALDU900-12 to 20 Float switch mounting position Mounting thread M12 R 3.2 S 40 Q IN P M N M L A B C E E F G K J (Bracket mounting dimensions) H D S Bracket (Option) Panel (Option) 6 x 17 A B C D E F G H J K L M N P Q R S Model Port size ALDU600-06 ALDU600-10 ALDU900-12 ALDU900-14 ALDU900-20 289 291.2 453 453 476 24.5 13.6 51 45.5 14.5 69.5 78.2 89 94.5 102.5 4
Connector Connector for input or output devices with cable, D-sub connector or spring type terminal block.
x n +4 x (n -1) -57No.PS-OMM0002CN-F A B C D E 4 OFF F SMC URL http://www.smcworld.com 2008-2014 SMC Corporation All Rights Reserved No.PS-OMM0002CN-F
Solid state switch Model D-F8 Series Variations Bore size (mm) Rod end configuration Stroke (mm) Clean room series 4 6 8 10 15 20 Action Series Auto switch Double acting Male thread Without thread Nil 4 Single acting (spring return) Double acting 6 Single acting (spring return) CUJ Solid state switch D-F8 D-F9 Female thread Double acting 8 Male thread Single acting (spring return) Double
zoo ~ ) 2 ~ i 100 E 12 z ,; 2 ~ E , E :; 100 V ~ " I ~ , , " , f< ' ~ 0 u: , ' l ~ ~ 0 w 0 5 10 ~ V " ~ 0 ] w 0 5 10 Needle revolullOOs (RevolutIOns) Needle revolutions (Revolutions) ASP530F ASP630F 12. 1500 'E 20 E 12 11~14:l~ z ~ ~ ~IOOO 15 . , g j " . 000 14 'E ' , ' h E cr z 12 ,; "'500 . l/ : 4 i 1,(" 0 to, 1~ OS, D9 10 ~ E ~ " , "' g 10 : ; ~.; 0 --:' 500 ~ ~ 5 :J" ~ -r ~ 0 w
-X 20Data 6-2-1 2 Air Cylinder Double Acting, Single Rod Series CJ1 4 Specifications Double acting, Single rod Action Air Fluid 1.05 MPa Proof pressure 0.7 MPa Maximum operating pressure JIS Symbol Double acting, Single rod 0.2 MPa Minimum operating pressure 10 to 70C (No freezing) Ambient and fluid temperature Piston speed 50 to 500 mm/s Formation of small series of a double acting cylinder