Allowable Load Weight: 2 [450 lbf (2 KN)], Stroke: 12 (12mm, MACM2), Table Option: G (Stainless Steel, Polished Finished), Sensor Type: Unsupported, Relief Port: No

Allowable Load Weight: 2 [450 lbf (2 KN)], Stroke: 12 (12mm, MACM2), Table Option: N (Cast Nylon), Sensor Type: Unsupported, Relief Port: No

Safety cannot be assured in the case of unexpected malfunction. 0 2 4 6 8 10 Input No. 12 14 No corrosive gas or dust Operating atmosphere 250 g Weight 450 g Provide grounding to assure the safety and noise resistance of the Serial System. Individual grounding should be provided close to the product with a short cable. 138 Seal cap (for M8 connector socket): 16 pcs.

COUPLED, ACTUATOR, CY3R MAGNETICALLY COUPLED CYL, I5, 25MM CY3R CLEAN ROOM, 1.98416 lb, ModelBore size (mm)Port sizeLubricationStandard stroke (mm)Maximum manufacturable stroke (mm)Cushion RubberAir12-CY3R2525Rc1/8 NPT1/8 G1/8Non-lube100, 150, 200, 250, 300, 350,400, 450, 500, 600, 700, 8001300(Both sides)?

COUPLED, ACTUATOR, CY3R MAGNETICALLY COUPLED CYL, I5, 25MM CY3R CLEAN ROOM, 2.02825 lb, ModelBore size (mm)Port sizeLubricationStandard stroke (mm)Maximum manufacturable stroke (mm)Cushion RubberAir12-CY3R2525Rc1/8 NPT1/8 G1/8Non-lube100, 150, 200, 250, 300, 350,400, 450, 500, 600, 700, 8001300(Both sides)?

END PLATE XRAY-450, ACTUATOR, GRIPPER, LC, 32MM GRIPPER, .00000 lb

Valves are easily replaced without changing existing piping.Direct operated, 3 port solenoid valve for manifold - New VX Series, Max. system pressure (MPa): 2.0, Flow characteristics: 0.08 ~ 0.5 Cv, Voltage: 48, 100, 200, 110, 220, 230, 240VAC; 12, 24VDC, VALVE, MEDIA FOR MFLD, AIR, 3 PORT SOLENOID VALVE, 450 lb

external pilot) -100kPa to 0.7MPa (external pilot, pilot pressure range) 0.25 - 0.7MPa , Effective area mm 2 (Cv): body ported 10.6 (0.59); base mounted 12.6 (0.7) , Coil rated voltage: 3, 5, 6, 12, 24VDC; 100, 110, 200, 220VAC , Response time (0.5MPa) w/o indicator light & surge voltage suppressor: 32ms or less , Ambient & fluid temperature: 50°C, VALVE, SOL, 4/5 PORT SOLENOID VALVE, 450

IP65 enclosure , Conforms to UL94V-0 flame resistance , Special construction improves service life when compared with current shading coil , Power consumption: size 1 - 4.5w; size 2 - 7w; size 3 - 10.5w , Body material: aluminum, resin, 2 PORT VALVE, 2 PORT VALVE, 450 lb

Series: LEKFS, Size: 40, Motor Mounting Position: In-line, Motor Type: E (Battery-less absolute, 24VDC, Step), Lead: A (Size 16: 10mm, Size 25: 12mm, Size 32: 16mm, Size 40: 20mm), Stroke: 450

Series: LEKFS, Size: 40, Motor Mounting Position: R (Right Side Parallel), Motor Type: E (Battery-less absolute, 24VDC, Step), Lead: B (Size 16: 5mm, Size 25: 6mm, Size 32: 8mm, Size 40: 10mm), Stroke: 450, Motor Option: B (with Lock), Seal Band Stopper: N [Roller Type Seal Band Stopper [Grease Free]], Actuator Cable Type, Length: R5 (5), Controller: C9F (EtherNet/IPâ„¢ with STO Sub-Function

32, 40, 50, 63 , Maximum operating pressure: 0.7MPa , Ambient temperature: -10 to 60C, 15MM CY3R DOUBLE-ACTING, ACTUATOR, CY3R MAGNETICALLY COUPLED CYL, GD, 15MM CY3R DOUBLE-ACTING, 0.92907 lb, ModelBore size (mm)Port sizeLubricationStandard stroke (mm)Maximum manufacturable stroke (mm)Cushion RubberAir12-CY3R1515M5 x 0.8Non-lube50, 100, 150, 200, 250, 300, 350, 400, 450

t weight ht weight t weight ht ht Series 240 350 310 CY1F CY1H MY2H 198 225 205 294 260 50% reduction in weight 50% reduction in weight 50% reduction in weight 50% reduction in weight For 100mm stroke cylinder Weight kg Guide un Base gasket 10 15 25 Series CY1F CY1H MY2H 0.7 1.0 1.1 2.2 1.3 2.5 4.6 3.2 For 300mm stroke cylinder Actuator unit Model Bore Cushion Piping (mm) 50 10 400 450

J 1n 114 250 3/8 350 112 450 3/4 5 5 0 1 650 1 1i2 850-2 I I Port Sr" I PT pofts ilodel Bracket Beplacement Element AMG150 BM5'I AMG-EL150 02 1/4 (AMG 1s0) 03 3y8 (AMG 250) 04 1/2 (AMG 350) 06 3/4 (AMG 4s0) 1 o 1 ( A M G 5 5 O ) 14 1 1/2 (AMG 6s0) 20-2(AMGsso) AMG250 BM52 AMG-EL25O AMG35O BM53 AMG-EL35O AMG45O BM54 AMG-EL45O AMG550 BM55 AMG-EL55O AMG65O BM56 AMG-EL65O AMG850 BM57 AMG-EL85O

IP65 enclosure , Conforms to UL94V-0 flame resistance , Special construction improves service life when compared with current shading coil , Power consumption: size 1 - 4.5w; size 2 - 7w; size 3 - 10.5w , Body material: aluminum, resin, 2 PORT VALVE, 2 PORT VALVE, 450 lb

These valves are normally closed, 12 or 24VDC and are available for air, water, or oil applications.New generation valve corresponding to energy-saving needs , Reduction of running cost and of temperature increase , Body material: Brass (C37), Stainless Steel , Seal material available: NBR, FKM, EPDM, PTFE, Rated voltage: 24VDC, 12VDC, 2 Port Sol Valve, Direct Operated, 2 PORT VALVE, 450

Power consumption 50/ 60Hz, 3 phase 200V kW 5.6 7.3 Earth leakage breaker capacity Note 7) (Sensitivity current 30mA) A 50 Cooling method of the condenser Water-cooled type Air reheater / after cooler Second class pressure vessel Refrigerant R407C (HFC) Amount of refrigerant to be filled kg 2.25 4.5 Auto drain ADH4000-04 Port size 80A (3B) JIS10KFF flange 100A (4B) JIS10K flange Weight kg 450

Please contact us for the latest version.sales@ocaire.com, CYL, RODLESS, CLEAN ROOM, ACTUATOR, CY2R CYL RODLESS COUPLED, L5, 32MM CY2R CLEAN ROOM, 3.36817 lb, ModelBore size (mm)Port sizeLubricationStandard stroke (mm)Maximum manufacturable stroke (mm)Cushion RubberAir12-CY3R3232Rc1/8 NPT1/8 G1/8Non-lube100, 150, 200, 250, 300, 350,400, 450, 500, 600, 700, 8001300(Both

IP65 enclosure , Conforms to UL94V-0 flame resistance , Special construction improves service life when compared with current shading coil , Power consumption: size 1 - 4.5w; size 2 - 7w; size 3 - 10.5w , Body material: aluminum, resin, DIRECT OPERATED 2 PORT VALVE (N.C.), 2 PORT VALVE, K40, 450 lb