H I J K L M N Bore size (mm) 32 40 50 Stroke range (mm) 20 to 100 44 37 13 16 45 18.5 M8 x 1.25 60 4.5 14 7 34 5.5 20 to 100 51 44 13 16 52 20 M8 x 1.25 69 5 14 7 40 5.5 30 to 100 57.5 49.5 15 20 64 28.5 M10 x 1.5 86 7 17 8 50 6.6 mm OB P Q RB S U Z Bore size (mm) 32 40 50 9 Rc 1/8 23 7 58.5 31.5 14 9 Rc 1/8 28 7 66 35 14 11 Rc 1/4 31.5 8 80 41 19 Refer to page 9 for details on rod end
198 19.9 199 20.0 200 19.5 10 7.5 20 14 10.5 25 20 13 27 4 4.5 9.2 6 5.5 12.6 6 8 17.2 145 14.6 146 14.7 147 14.8 148 14.9 149 15.0 150 10.5 105 10.6 106 10.7 107 10.8 108 10.9 109 11.0 110 14.5 D11 7.5 20 15 10.5 25 4 4.5 9.8 6 6 13.3 -X 533 C(L)KQG32 Series Dimensions CLKQGl32 (Clamping height LOW type) The figures below indicate the CLKQGB32-lRCL-X2081.
(A) 4 (B) 2 (A) 4 (B) 2 0.6 SS5YJA5 The remainder of the manifold part number is called out the same as an SS5YJ5 0.5 1 (P) 3 (R) 1 (P) 3 (R) Pilot pressure range 3 position pressure center 0.4 (A) 4 (B) 2 Specify the part numbers for the valve(s), blank plate assembly and manifold base. 0.3
1) Only applies to S material with TW4 connections.
For connection with a load having an external support/guide mechanism, select an appropriate connection method and perform careful alignment.
20 20 20 20 20 20 20 9.5 9.5 9.5 11.5 D-F7, F7V D-J79, J79C D-F7W, F7WV D-J79W D-F7BAL, F7BAVL D-F7NTL, F79F D-F7W D-J79W D-F7BAL D-F79F D-F9BAL 6 6 6 6.5 Number of auto switch D-F7LF D-A9 D-F9 D-A79W 7.5 7.5 8 D-F7LF 7.5 D-F9, F9V D-F9W, F9WV D-F9BAL 1 pc. 2 pcs. 20 20 20 20 25 25 20 20 5.5 5.5 5.5 6.5 The operating ranges are provided as guidelines including hystereses and are not guaranteed
150 H 166 187 187 218 218 241 241 277 334 1/8, 1/4, 3/8 1/4, 3/8 1/2 3/8, 1/2 3/4 1/2, 3/4 1 3/4, 1 1, 11/2 5.5 6 6 7 7 9 9 9 11 10 10 10 10 10 10 10 10 10 63 76 76 90 90 106 106 122 160 20 20 20 20 20 20 20 20 20 63 76 76 90 90 106 106 122 160 100 113 119 145 151 166 173 200 253 13 13 16 16 19 19 22 22 32 159 172 178 204 210 225 232 259 311 AMG150 AMG250 AMG350 AMG450 AMG550 AMG650 AMG150
AT37C-14 AFF37B-14 IDF37C1-3 AM650-14 AMD650-14 55 7.5 HAW75-20 AT55C-20 IDF55C-3 AM850-20 AM850-20 AMD850-20 75 10.0 HAW110-30 AT75C-20 IDF75C-3 AMD850-20 110 15.0 AT125C-30 AFF125A-30 IDF120D-3 AMD910-30 150 20.0 AT150C-40 AFF125A-30 IDF120D-3 AMD910-30 220 30.0 AT220C-40 AFF220A-40 IDF150D-3 50 Hz area 60 Hz area IDF1D-1 IDF2D-1 IDF3DIDF4DIDF6DIDF8DIDF11CIDF15CIDF22C1-3 IDF22C1
25 12 16 20 25 Relief type Vacuum suction type 5, 10, 15, 20, 25, 30 5, 10, 15, 20, 25, 30, 35, 40, 45, 50 M5 x 0.8 M5 x 0.8 Double acting Single rod 5, 10, 15, 20, 25, 30 5, 10, 15, 20, 25, 30, 35, 40, 45, 50 Suction Flow Rate of Vacuum Suction Type (Reference values) Specifications Suction flow rate L/min (ANR) Bore size (mm) 12/16/20/25 Size 5 12/16/20/25 Item Proof pressure 1.5 MPa Maximum
Two Hand Control Valve VR51 Series RoHS An output is available through synchronized, twohanded operation (within 0.5 s)!
Retainer prevents an accidental loss of needle.
Wide Opening Air Gripper Series MHL2 Parallel Style/10, 16, 25, 20, 32, 40 How to Order D 16 MHL 2 1 Y59A S Wide opening Number of auto switches 2 1 n S 2 fingers 2 Numbers of fingers n Bore size 10mm 16mm 20mm 25mm 32mm 40mm 10 16 20 25 32 40 Auto switch Without auto switch (Built-in magnet) Auto switch specifications Action Load voltage Auto switch model no.
Absolutely never use in an atmosphere where explosive gases are used. The compact manometer does not have explosion proof construction. If used in an atmosphere of explosive gases, there is a possibility of causing an explosion, and therefore, should absolutely not be used under these conditions. 1. The compact manometer can be used for measurement of air and non-corrosive gases.
Absolutely never use in an atmosphere where explosive gases are used. The compact manometer does not have explosion proof construction. If used in an atmosphere of explosive gases, there is a possibility of causing an explosion, and therefore, should absolutely not be used under these conditions. 1. The compact manometer can be used for measurement of air and non-corrosive gases.
20 23 30 30 35 23 23 25 72 86 114 33 37 55 1 1 1 2 17-3-78 9 The VX series will be revised shortly.
An unexpected malfunction in the system composition devices is likely to occur due to the malfunction of machinery or equipment. 3. After maintenance, make sure to perform an appropriate functionality inspection. In the case of an abnormality such as a faulty operation, stop operation at once. An unexpected malfunction in the system composition devices is likely to occur. 4.
P10 P10F Max. 0.7 x 20 O-ring 4 Hexagon socket head screw 2 Option Description Part no.
20 10 0 100 Suction flow [L/min(ANR)] Air consumption [L/min(ANR)] Vacuum pressure Vacuum pressure [kPa] Vacuum pressure [kPa] 80 60 Suction flow 40 20 Air consumption 0 0 10 20 30 40 Supply pressure [MPa] Suction flow [L/min(ANR)] ZHP-10 ZHP-10 (Supply pressure: 0.35 MPa) 100 90 80 70 60 50 40 30 20 10 0 0 0.1 0.2 0.3 0.4 0.5 0.6 100 90 80 70 60 50 40 30 20 10 0 100 Suction flow [L/min(