D1 D2 L1 L2 L3 L4 A Model d T Weight (g) H D1 D2 L1 L2 L3 L4 A Max.
D1 D2 L1 L2 L3 L4 A Model d T Weight g H D1 D2 L1 L2 L3 L4 A Max.
3 Product image Socket Socket Plug Plug Socket For DeviceNetTM (Plug, A-coded) Number of functional poles M12: 5 pins Key type A-coded (Normal key) DeviceNetTM / CANopen2 5 3 4 4 3 5 1: DRAIN: NC 2: V+: NC 3: V: NC 4: CAN H 5: CAN L 1: DRAIN 2: V+ (Red) 3: V (Black) 4: CAN H (White) 5: CAN L (Blue) 1: 2: 3: CAN GND 4: CAN H 5: CAN L 1 2 Pin assignment 2 1 Plug, A-coded Socket, A-coded (
VND50D-32A VND60D-40A VND70D-50A 1 8 1 4 1 4 1 4 1 2 1 1 2 105 120 140 77 96 113 53 60 74 26.5 30 37 121.5 138 161 20 24 24 130.5 148 171 8 10 12 55 63 74 Port size/Flange: 32F, 40F, 50F J (Valve open) Indicator (Option) Pilot port E 12(P1), 10(P2) Port size: refer to table below P1 P2 H H D B A 32 B C G F 4 x 2 x 18 mounting hole A Applicable flange 1(A), 2(B) Pilot port 12(P1), 10(P2)
Body mounting dimension AC AC Window for removal H AD Window for removal H AD Body mounting dimension Body mounting dimension Element Element FH FH (mm) adjustment range A B C D F G H I L M S U V r AC AD AG 1 2 3 4 5 Standard T dimension Port size (Nominal size) T dimension HOW 1/2B (04) 3/4B (06) 1B (08) 1 1/4B (10) 1 1/2B (12) 2B (16) 2 1/2B (20) 3B (24) 215 215 215 265 265 265 325 325
LJ1-7-G DVO P0820 Only series LJ1 H S10 has the T-nuts built into the body. LJ1-7-R MR-RB013 Non-standard Motor Cables LJ1-7-Y JUSP-RG08 These are cables for connecting non-standard motors and drivers. Cable lengths other than those shown below should be arranged by the customer.
Nil N F Rc NPT G Nil C The cable and connector are shipped unassembled.
Suction Verification High Vacuum Suction Workpiece 1 Workpiece 2 Workpiece n Max. A P_1 H_1 n_1 Formula for Obtaining the Set Value Min.
Rubber bumper/Shock absorber Cushion Not required (Non-lube) Lubrication 0 to 250 st: +1.0, 251 to 1000 st: +1.4, 1001 st and up: +1.8 Stroke length tolerance (mm) 0 0 0 19.6 53.9 137 231 363 588 922 Type H Holding force (N) 81.4 154 221 358 569 Type L Standard equipment Auto switch mounting rail In the case of setting an auto switch at the intermediate position, the maximum piston speed
Universal Type/Metric Size Applicable tubing O.D. d H D1 (Hexagon width across flats) M L3 A L4 L5 D3 D2 L1 Connecting thread T L2 Uni thread H D1 D2 L1 L2 L5 A Max. Min. Max. Min.
Grommet (G), (H): V11 24(A)-G H-M5 13.1 (Light/Surge voltage suppressor) 5 + 13 15.5 3 13 3 28.5 [32.4] 10 G: Approx. 300 H: Approx.600 (Lead wire length) Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 1 30.9 [33.1] 25.1 11.4 5.7 5.7 5.7 2 1 7 5 9.5 5 19 (Piping
---t;F=f=='Tjt IN Bracket (Option) N ...'---Ht-t---t-+-H I--i IN o I w c.
1 1) N NPN P PNP 2 ZL3/ZL6 ZL3-EJ1-H-A 1 2) 1) M 0.35 MPa H 0.50 MPa 4 M4x110 2)1 :0.760.84Nm V * 1 3 ZL3 ZL3-SC1-A 4 ZL3 ZL3-SE1-A 1 2 18 No.ZL3-OM00801-A 5 ZL6 ZL6-SC1-A () * 6 ZL3/ZL6 ZL3-EP1-1 -A 1 1 Rc F G N NP 7 ZL3/ZL6 GZ33-K1K-01-X56 (kPa ) GZ33-K1K-01-X56 (inHg/psi ) * *inHg/psi 8 ZL3 ZL3-AD3-A 19 No.ZL3-OM00801-A 8. 8.1 ZL3 12 1 22 3(0.760.84Nm)
Recommended Parameter Values [LEF] LEFS25 LEFS32 LEFS40 Series Lead symbol H A B H A B H A B Lead 20 12 6 24 16 8 30 20 10 Initial value Recommended Value Parameter *1,*2 Para No Number of command input pulses per revolution *3. PA05 100 100 Electronic gear numerator *3. PA06 1 100 (Positioning mode: 10) Electronic gear denominator *3.
Word0:IN05(bit05) )No.1 bit0:IN0=ON 15:IN15=OFF (3)Word1,bit415: No. bit ON bit OFF ) [] Word1, bit6=ON Word1,bit45715=OFF (4)Word2,bit89 Word317 )[]50.00[mm] 5000[0.01mm]=(01388)h Word4:(L)= (1388)h Word5:(H)= (0)h (5)bit Word2,bit0:=ON ON (6)Word0:BUSY=ON (7)Word0:INP=ON (INP ON INP(P.34)) Word0:BUSY=OFF Word0:INP=ON Word0:BUSY=OFF 24V 0V (2) ON OFF IN05 SVON (DRIVE ) OFF DRIVE
86 113 6.5 14 24 34 H Reference dimension after screwing into R threads.
(Station 1) Light/surge voltage suppressor 50.5 86.5 71.5 68.2 56.5 Individual SUP spacer 7.5 19.7 Individual EXH spacer Block separation lever L Dimension n: Stations L n 2 148 137.5 122.5 13 3 173 162.5 138.5 17.5 4 185.5 175 154.5 15.5 5 198 187.5 170.5 14 6 210.5 200 186.5 12 7 235.5 225 202.5 16.5 8 248 237.5 218.5 15 9 260.5 250 234.5 13 10 285.5 275 250.5 17.5 11 298 287.5 266.5 16
16 16 16 16 16 16 16 0 0 0 0 0 0 0 VQ, SX, SY & SV VQ2000/4000/5000 SQ1000/3000, SZ3000/5000 (N)VFR/S, (N)VZS, ISO VQ, SX, SY & SV VQ2000/4000/5000 SQ1000/2000, SZ3000/5000 EX120/121/122-SUW1 EX123 (U, D)-SUW1 EX140-SUW1 IN313-UW1 EX120/121/122-SUH1 EX123 (U, D)-SUH1 EX140-SUH1 N Y N NKE Wire Saving System 13 NKE N N Y N NKE Wire Saving H System EX120/121/122-SCS1 EX120/121/122-SCS2 EX124
1) x 27 64.5 U side D side n Station number 4 2 1 3 L2 L1 45 98 (n-1) x 27 27 56 56 2 Indicator light 21 Manual override 188.5 (3-position) 173 (Double dual 3-port) 157.5 139.5 (Single) 14 14 14 14 131 8 115 12 12 12 12 SMC 4 x M5 mounting holes Formula: L1 = 27n + 85, L2 = 27n + 138.5 n: Stations (Maximum 16 stations) Dimension (mm) 7 L n 9 328 381.5 112 165.5 1 166 219.5 301 354.5 8 274