Model number: HRS0-F-0 The transition connector from Rc to G is enclosed as an accessory. For G piping, be sure to use this connector.
Model number: HRS0-F-0 The transition connector from Rc to G is enclosed as an accessory. For G piping, be sure to use this connector.
Finger assembly Piston assembly MHZA2-6H MHZA-A0607 Main body of adaptor Mounting screw for adaptor Seal MHZA2-6K MHZA-A0608 Endboss assembly MHZA2-6M MHZA-A0609 MHZA2-6E MHZA-A0610 The end boss assembly other than type E should be mounted on the special body. Replacement part/Grease pack part no.: GR-S-010 (10 g) 15 - 3-6.
Stop 5 Series REA Sine Rodless Cylinder Dimensions (mm) REA 25, 32, 40 1in = 25.4mm Effective thread depth J L 0 0.1 NN G 4-MM H G B 2Port size I X D NB NB T N K W N S + Stroke F NA F R ZZ + Stroke MM x J B D F G H I K L N NA NB NN Model Port size REA25 REA32 REA40 Rc(PT) 1/8 46 27.8 13 8 20.5 34 10 70 M5 x 0.8 x 8 15 30 13 M26 x 1.5 Rc(PT) 1/8 60 35 16 9 22 40 15 80 M6 x 1.0 x 8 17 36 15
close proximity with each other either horizontally or vertically Plug connection ower supply output connection 30 e-Con connector Analog output or auto shift input 2 outputs + Sensor connection M5 female thread, through type (with mounting holes) M3 M5 female thread, through type M5 6 reducer 4 reducer R1/8,NPT1/8 Applications Manifolding is possible.
How to Order VFN212 02 N 5 F D Z CE marking NAMUR Interface Nil Q CE marked product Voltage Thread type 1 100 VAC, 50/60 Hz 2 200 VAC, 50/60 Hz 3 110 to 120 VAC, 50/60 Hz 4 220 VAC, 50/60 Hz 5 24 VDC 6 12 VDC 7 240 VAC, 50/60 Hz Nil Rc (PT) F G (PF) N NPT Electrical entry Solenoid G Grommet E Grommet terminal T Conduit terminal D DIN terminal Nil Single solenoid D Double solenoid Manual
with each other either horizontally or vertically Plug connection ower supply output connection 30 e-Con connector Analog output or auto shift input 2 outputs + Sensor connection M5 female thread, through type (with mounting holes) M3 M5 female thread, through type M5 6 reducer 4 reducer R1/8,NPT1/8 Applications Manifolding is possible.
F G H J K L M N P Q IDF1E Rc3/8 69 101 270 32 21 330 IDF3E Rc3/8 473 67 304 33 73 31 36 154 21 330 226 410 413 125 240 15 38 150 IDF2E Rc3/8 51 232 138 24 327 IDF4E / IDF6E / IDF8E / IDF11E ( 10 :0.8m) [ AC100V ] [ AC200V ] (:1.9m) [ AC200V ] (17) mm A B C D E F G H J K L M N P Q IDF4E Rc1/2 453 13 498 568 31 42 283 355 80 230 32 15 284 15 240 80 275 IDF6E Rc3/4 455 270 485 IDF8E Rc3/
MHZ-A1010 MHZ-A16010 MHZ-A2010 MHZ-A2510 Ass'y MHZ-AA1004 MHZ-AA1604 MHZ-AA2004 MHZ-AA2504 3 1= 2= 3= /GR-S-010 (10g) W= K= M=M5 E= Assy E 17 - 32,40 / / / / 11 1 12 2 13 3 14 C 4 15 A 5 16 6 17 NO 7 18 NC 8 19 NBR 9 20 NBR 10 21 NBR MHZ2-32 MHZ2-40 MHZ32-PS MHZ40-PS 19,20,21 MHZ2MHZ-A3202 MHZ-A4002 MHZ2-1 MHZ-A3202-1 MHZ-A4002-1 4,5,6,11,13 Ass'y MHZ2-2 MHZ-A3202-2 MHZ-A4002
For sub-plate type, manifold type 41, S41, 42, S42, 42R, S42R (With gasket and screws) Body option Nil: Individual pilot exhaust type Electrical entry Manual override 24, 12, 6, 5, 3 VDC/100, 110, 200, 220 VAC 24, 12, 6, 5, 3 VDC Nil: Non-locking push type Grommet L plug connector M plug connector M8 connector R port P, E port G: Lead wire length 300 mm L: With lead wire (Length 300 mm) M
Dimensions E C D E E L (Width across flats) M (Width across flats) M8 (KF Flange) (K Flange) Fn Fd C Detail of (a) (a) M Rc1/8 J H K B A G A Model A B C D E Fn Fd XLGR-80*-1* 90 250 117 45.5 38.5 114 110 XLGR-100*-1* 108 270.5 154 55 38.5 130 102 XLGR-160*-1* 138 339 200 65 38.5 180 153 Model G H J K L M XLGR-80*-1* 83 105 44 9 13 4 XLGR-100*-1* 102 92 58 9 13 4 XLGR-160*-1* 153 124 62 12.5
Note2:See specification table for refrigerant used in th e product. IDF100150F 6-2 Refrigerant with GWP reference 6 2 IDX-OM-M050 Air Dryer 6 References 6-3 Outer dimensions [IDF100F-30-] Heavy duty auto drain Ball valve (O.D.10, Length approx. 2m) is also available.)
95 g M12 175 g 182 g AWG23 0.72 mm 1.14 mm 4 3 m -15No.PS-OMS0004CN-D [mA] [V] A B 01MPa 0 1MPa -100100 kPa -100 kPa 100 kPa 0500 kPa 0 500 kPa -16No.PS-OMS0004CN-D A B PSE57-01 8 R1/8 PSE57-02 12 R1/4 M12 ZS-37-A 1 2 4 3 M12 ZS-37-B 3 4 2 1 M12 -17No.PS-OMS0004CN-D ZS-31-X D E F G H I ZS-31-X188 20 9 R1/8 Rc1/8 14 1.5 ZS-31-X175 29 13 R1/4 Rc1/4 17 1.6 -18No.PS-OMS0004CN-D Revision
IDU Series 6-2 Refrigerant with GWP reference 6 3 IDX-OM-W013 Air Dryer 6 References 6-3 Dimentions IDU3E / IDU4E / IDU6E Evaporation Illuminated thermometer switch Q3 B3 E D A3 P Compressed air inlet Port size Compressed air inlet Port size F G Inspection Grille [200V AC Inspection Grille specification] Terminal block C3 Ventilation direction Ventilation direction Ventilation air outlet
When actually mounting an auto switch, adjust the position after confirming the operating state of the auto switch. 95 Guide table10-MGF Dimensions 10-MGF40/63/100 4-N V D C D C E F H A + Stroke B + Stroke GB GA T X PP (Rc, NPT, G): Relief port 2-P(Rc, NPT, G) Port for extension Port for retraction When the cylinder is extended KA: T-slot for hexagon bolt 4-M K KB KC 6-K (6 positions) 9 9
,AC230V] [AC100V] POWER CORD POWER SUPPLY ENTRY(17) unitmm Model Thread Size A B C D E F G H J K L M N P Q IDU8E Rc3/4 270 485 859 31 902 365 1302 230 42 14 3002 80 3001 328 15 IDU11E Rc3/4 909 IDU15E1 Rc1 300 620 960 79 54 425 93 258 43 330 66 470 358 16 IDU Series 6-3 Dimentions 6 4 IDX-OM-W022 Air Dryer 6 References 6-4 Electrical Circuit IDU8E-10 IDU8E/11E-20/23 PC PE L N TB ILS ILS PTC
4 Rc1 10mm 1 2 kg 44 47 71 kW 7.5 11 15 1ANR 2065% 2 3 30mA 4() IDU Series 6-1 6 2 IDX-OM-W023 6 6-2 GWP (GWP) Regulation (EU) No 517/2014 IPCC AR4) R134a 1,430 1,430 R404A 3,922 3,920 R407C 1,774 1,770 R410A 2,088 2,090 (1) (2) IDU Series 6-2 GWP 6 3 IDX-OM-W023 6 6-3 A B E D Q Guige Guige G C Guige Guige [AC200V] [AC200V] Guige Guige F 10 (10) (820) J H K P
hole F Applicable screw M5 hexagon socket head cap screw M6 hexagon socket head cap screw M8 hexagon socket head cap screw Model AMP220 AMP320 AMP420 E OUT Maintenance space (mm) C B Bracket related dimensions Element service indicator related dimensions Port size (nominal size B) Model A D E I 66 80 90 J K L M N O P Q R S F 80 120 180 G 123 169 237 H AMP220 AMP320 AMP420 76 90 106 76 90
A C D E F G H B Composition of assembly Set nut (1349172) AP100 ARM2500 136314 30 34 70 5.4 15.4 55 2.3 M33 x 1.5 Bracket (B220) Inlet pressure (MPa) Set nut (131532) ARM3000 136414 75.5 8 41 40 6.5 53 2.3 M42 x 1.5 Bracket (B320) Note) Tighten the set nut securely and fix it.
Fittings & Tubing Air Cylinders Rotary Actuators V D C D C E F H A + Stroke B + Stroke GB GA T X PP (Rc, NPT, G): Relief port 2 x P (Rc, NPT, G) Port for extension Port for retraction When the cylinder is extended KA: T-slot for hexagon bolt 4 x M K KB KC 6-K (6 positions) 10 10 M12 x 1.75 M10 x 1.5 M8 x 1.25 M Bore size Standard stroke (mm) GB D A 170 140 10 10 38 38 36.5 E B F KC 11 11