SMC Corporation of America
Elite Part Number Search
Search Results "ISE10-M5-E-MGD"

A E Push type A Push-locking type E Dimensions: Single Dimensions: VZ1120-G-M5-X1 Push type A (Push type A) Manual override Manual override (Non-locking) (Mounting hole for manifold) Push-locking type E (Piping port) Manual override (Push-locking type E) ( ) Pressing makes the valve operate.

Refer to pages 5 and 6 for detailed selection procedures. 2 How to Select Series E-MY2 Moment / E-MY2C E-MY2C/M3 E-MY2C/M1 E-MY2C/M2 50 40 50 40 50 40 30 30 30 20 20 20 10 10 10 Moment (Nm) Moment (Nm) Moment (Nm) 5 5 5 E-MY2C25 E-MY2C25 4 4 4 3 3 3 E-MY2C25 2 2 2 E-MY2C16 E-MY2C16 E-MY2C16 1 1 1 0.5 0.5 0.5 100 200 300400500 1000 1500 100 200 300 400500 1000 1500 100 200 300 400500 1000

P.T. 1 (P) 3 (R) (A) 10.5 30 (L) With miniature indicator Pneumatic indicator 10 12 17 44 25.4 2 x 4.6 mounting hole 19.5 8.5 14 2 x M5 x 0.8 depth 4 * 0.5 MPa supply Model L A VM122-M5-00A 32.5 7.5 F .O.F .* 26 N VM132-M5-00A P .T. 1.5 mm VM123-M5-00A 28.5 3.5 O.T. 1.5 mm VM133-M5-00A T.T. 3 mm Roller lever VM123-M5-01A VM133-M5-01A VM123-M5-01SA VM133-M5-01SA 10 Polyacetal or hard steel

During Auto tuning Auto tuning failure A T 1 E R R 1 9 P V < 2 3 . 0 C # 1 A T F a i l u r e A u t o T u n i n g M O D E S h u t O f f C a n c e l : A T k e y <4> External sensor sampling cycle setting: Mode indication External Sensor Sampling Cycle. Default value: 180 sec. Setting range 10 to 999 sec.

(mm) Thread Weight g A B C D E F H Model Applicable tubing M3 x 0.5 M5 x 0.8 M-3AU-2 M-5AU-2 0.9 0.7 1.5 4.5 7 9 10 3 4 5 7.7 4 2 x 1 .2 3 2 1 4 Thread Parts list Material Brass Brass No. 1 2 3 Description Sleeve Barb fitting Gasket Note Electroless nickel plated Electroless nickel plated E D F NBR, Stainless steel B C A Width across flats H Barb elbow: M-3ALU-2, M-5ALHU-2 Applicable tubing

0.1 to 0.7 Miniature regulator ARJ210 Direct operated relieving style 0.2 to 0.7 M5 to 1/8 Miniature regulator ARJ310 Direct operated relieving style 0.2 to 0.7 M5 to 1/8 Regulator AR1000-6000 Direct operated relieving style Modular style 0.05 to 0.7 0.05 to 0.85 M5 1/8 to 1 Built-in pressure gauge Space saving 0.05 to 0.85 1/8 to 1/2 Regulator with integral pressure gauge AR2001-4001 Internal

Load mass kg Load mass kg m s m s Type of impact s m 1 m 2 Kinetic energy E1 Thrust energy E2 Fs Fs + mgs Fs mgs Absorbed energy E E + E Symbols : Speed of impacting object (m/s) m: Mass of impacting object (kg) F: Cylinder thrust (N) g: Gravitational acceleration (9.8m/s) s: Shock absorber stroke (m) Note) The speed of the impacting object is measured at the time of impact with the

Applicable blank plate assenbly SY100-77-1A VZ P R 20 stations 20 R port VS A port M5 X 0.8 P port M3 X 0.5 M5 X 0.8 M5 X 0.8 Note 1) SY114 (A) and SY124 (A) cannot be mounted on the same manifold.

x 0.8 thread depth 4 (Piping port) OUT IN Steel balls 12 Series CXSJ Dimensions: 15 to 32 Standard Piping U Q R T ZZ + Stroke Stroke J K SS + Stroke 1 D B M L Z I 1 G 0.2 (G) H A E F (Through) N ( I ) (L) (Z) (G) C NN A B ZZ C D E M F G H I J K L N NN Q R U 2-M5 0.8 thread depth 4 2-M5 0.8 thread depth 4 2-M5 0.8 thread depth 4 2-Rc1/8 thread depth 5 SS T Bore size (mm) 2 2-4.3 through

x 0.8 thread depth 4 (Piping port) OUT IN Steel balls 12 Series CXSJ Dimensions: 15 to 32 Standard Piping U Q R T ZZ + Stroke Stroke J K SS + Stroke 1 D B M L Z I 1 G 0.2 (G) H A E F (Through) N ( I ) (L) (Z) (G) C NN A B ZZ C D E M F G H I J K L N NN Q R U 2-M5 0.8 thread depth 4 2-M5 0.8 thread depth 4 2-M5 0.8 thread depth 4 2-Rc1/8 thread depth 5 SS T Bore size (mm) 2 2-4.3 through

Fittings & Tubing Air Cylinders Rotary Actuators HB HT HC X N A H HA CB W K 2 x plug 2 x P HP (Piping port) 4 x J x E T 4 x counterbore dia.

Within on e-revolution position Cumulativ e feedback pulse s in pulse in pulse unit unit Within on e-revolution position Cumulativ e feedback pulse s in 1000 in 1000 pulse unit pulse unit Load to motor inertia moment ratio Servo mot or speed in 10r/min unit Servo mot or speed in r/min unit Bus volta ge Droop pulses in pulse unit Settling time (Note 1) Droop pulses in 1000 pulse unit Current

R S T E E E 24 25 28 29 30 31 37 38 Communication cable Communication cable outlet (also used as signal cable outlet) 27 Series HRG Optional Accessories Note) Please order separately. Necessary to be fitted by customer.

Please contact us for the latest version.sales@ocaire.com, ISE30 M5 PT VERSION, INSTRUMENTATION, ISE30/ISE30A PRESSURE SWITCH, AA, ISE30 M5 PT VERSION, 0.22046 lb

ISE30 M5 PT VERSION, INSTRUMENTATION, ISE30/ISE30A PRESSURE SWITCH, AA, ISE30 M5 PT VERSION, 0.22046 lb

5 M5 port M5 port y y u u !7 !7 q w e r t q w e r t o o !0 !0 !1 !1 i i !4 !4 !2 !2 !3 !3 !6 !6 Component Parts Description Material Description Material No.

Determination of loads kinetic energy (E) bore size Determination of bore size Review of larger bore size E Es E Es E = m E 2 a ( ) 2 (Refer to page 29) 1000 P Ps P Ps Determination of pressure for intermediate stop (p) (Refer to page 29) Review of larger bore size and operating pressure Model determination 1 Magnetically Coupled Rodless Cylinder Low Profile Guide Type Series CY1F Types

trimmer 4 x M4 x 0.7 depth 5 (For mounting, opposite side: Same) Bar length (mm) 300, 380, 620, 780 1100, 1260, 1500, 1900, 2300 Fitting M-5P-X112 KJH04-M5-X34 Note) Note) Plug (M-5P-X112) 1 pc. is shipped together.