SMC Corporation of America
Elite Part Number Search
Search Results "ISE20B-L-01-D"

Please change the parameter in the initial setting. *3 The minimum unit of the travel distance of the actuator should be 1 [m]. *4 When the motor mounting position is right side parallel (LEY*R / LEYG*R) or left side parallel (LEY*L / LEYG*L), the rotation direction selection is 0(+: Counter motors side). -28- LEY63 LEY63D Lead symbol A B C L A B C Series Lead 5(2.86) 20 10 5 20 10 5 (Including

Refer to manifold dimentions drawings for L dimention. 25 35 5.5 Each manifold can be mounted on a DIN rail. Order with the option symbol -D to specify DIN rail mounting style.

L/A indicator Table 6-2 L/A indicator L/A Meaning Green ON Connection via Ethernet to the SI Unit via BUS IN/OUT But no transmission or reception of Ethernet telegrams on BUS IN/OUT Orange ON or Connection via Ethernet to the SI Unit via BUS IN/OUT Transmission or reception of Ethernet telegrams on BUS IN/OUT Flashing Green/Orange OFF No physical connection to the port Green Flashing Received

/min (ANR)) Air flow rate (l /min (ANR)) AMH550 AMH250 B B 3 4 1 4 Inlet air pressure Air pressure Pressure drop (MPa) Pressure drop (MPa) Max. flow line Max. flow line Air flow rate (l /min (ANR)) Air flow rate (l /min (ANR)) AMH650 AMH350 B 1B 3 8 Inlet air pressure Air pressure Pressure drop (MPa) Pressure drop (MPa) 0.5 Max. flow line Max. flow line Air flow rate (l /min (ANR)) Air flow

Procedure 1In the [Parameter] 01 dialogue box select the ORIG tab. And the direction of the origin is changed from 2 (CCW) to 1(CW). Procedure 2In the [Parameter] 01 dialogue box press the "Download All" radio button. Procedure 3Power supply OFF ( Power supply ON) -24- The origin offset means the value of the origin.

30 40 13 XL-OMY0002 8 X L D 25 M9N A A ( X A N1 A ) 25 40 B A 50 63 80 C P11 160 100 FKM() P8 KF (NW) D K (DN) () A / A F G A J B K C L M M9N D-M9N M9P D-M9P / 560 M9B D-M9B A90 D-A90 H0 H4 H5 5150 100 A93 D-A93 120 M9// 25H4 14 XL-OMY0002 9. 200 2580 100 100,160 [] 1 1.5 1 XLD-25,XLD-40,XLD-50,XLD-63,XLD-80 200 XLD-100,XLD-160 100 : FKM 110 Pa <> 15 XL-OMY0002

bracket) are included with the above parts. 3 Series VCB Direct Operated 2 Port for Heated Water Dimensions (mm) 1in = 25.4mm Grommet: G Conduit: C Q Approx. 300 F D Approx. 280 D Q F C G1/2 C R R E E B A H 2-P Port size 2-P A 2-M Thread depth N B H Port size 2-M Thread depth N L L K K Conduit terminal: T F (Q) 34 25 U R C G1/2 E B A H D 2-P Port size (S) 2-M Thread depth N L K (mm) Electrical

(Including band and screw) MVGQ Bore size (mm) 20 25 32 40 50 63 80 100 CC Applicable auto switch RB D-C7, D-C80 D-C73C, D-C80C Reed J BMA2-020 BMA2-032 BMA2-040 BMA2-050 BMA2-063 BMA2-025 D-H7/H7C D-H7W D-H7NF/H7BAL Solid state DD-B5, D-B64, D-B59W Reed -X D-G5/K59/G5W/K59W BA-04 BA-32 BA-05 BA-06 BA-01 BA-08 BA-10 BA-02 Solid state 20D-G5NTL, D-G5BAL D-A3, D-A44 Reed BD1-04M BD1-02 BD1

0 06, 08, 10 Flow rate [L/min(ANR)] Flow rate [L/min(ANR)] i q y !2 !1 !3 Number of needle rotations Number of needle rotations AS3201F, AS3211F AS4201F, AS4211F r Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa Component Parts No.

Note 2) Unit: kPa, MPa Panel mount adapter + Front protection cover L Lead wire with connector (Lead wire length 2 m) Note) With connector cover G Connector cover D Note) For output types N and P, the number of core of lead wires will be 3, and for other types, it will be 4. 33

Series VXA31/32 Dimensions P port Bracket Pilot port J (Spanner flat) Port size P Port size Rc With bracket K 6 7.5 Symbol Model A B C D E F G H J L 29 32 M 14.5 17 1 8 1 4 VXA31 VXA32 19 25 20 20 18 21 20 20 22.5 27.5 42.5 47.5 71 80 81 90 21 27 , , 1 4 3 8 17-3-104 The VX series will be revised shortly.

Panel mount adapter + Front protective cover ZS-27-D Mounting screw (M3 x 8L, 2 pcs.)

3 1/2 5 PORTS D D **I 37 **I 39 F J 4 14 2 12 E K G M12 CONNECTOR (OPTIONAL) L 1 5 3 M M H SIZE 2 1/2 SIZE 3 3/4 2 PORTS EA, EB PORTS N N ALL DIMENSIONS ARE IN MILLIMETERS R S T EA EB P SIZE 2 3/8, 1/2, 3/4 SIZE 3 1/2, 3/4, 1 P PORT Q P O * 3/8 14.5 1/2 16 3/4 18.5 A B C D E F G H I J 29 8.5 ** 22 * 28 48.5 36 32.5 52 32.5 47.5 SIZE 2 SIZE 3 22 27 47 45 40 65 40 71 SIZE 3 SIZE 2 K L M N

C J G5-S Air-hydro Converter: CCT40 CV MVGQ 50 M32 x 2 Lube-plug CC Rc 1/4 Air port size RB J D-X 20Rc 1/4 Oil port size Data L Dimension (Effective oil level stroke) (mm) Effective oil level stroke (mm) 50 100 150 200 300 L 213.5 263.5 313.5 363.5 463.5 10-17-9 Valve Unit Series CCVS/CCVL How to Order CCV S 1 1 1 U1 Suffix S Single valve Valve unit size Unit for CC63 (Unit mounted to CCT63

C J G5-S Air-hydro Converter: CCT40 CV MVGQ 50 M32 x 2 Lube-plug CC Rc 1/4 Air port size RB J D-X 20Rc 1/4 Oil port size Data L Dimension (Effective oil level stroke) (mm) Effective oil level stroke (mm) 50 100 150 200 300 L 213.5 263.5 313.5 363.5 463.5 10-17-9 10 Valve Unit Series CCVS/CCVL How to Order CCV S 1 1 1 U1 Suffix S Single valve Valve unit size Unit for CC63 (Unit mounted to

ID 0 1 2 1 063 1ABS() 3 1 ) 2INC() 4 H 2 065500 mm/s 5 L 6 3 7 2 4 2147483647 0.01mm 8 1 9 0 ID1 10 H 2 065500 mm/s2 11 L 12 H 2 065500 mm/s2 13 L 14 1 030 10% 15 1 030 10% 16 1 0255 mm/s 17 1 030 10% 18 H 2 065500 0.01mm 19 L ID2 2039 ID1 ID3 4059 ID1 ID4 6079 ID1 ID5 8099 ID1 ID6 100119 ID1 ID7 120139 ID1 ID8 140159 ID1 ) 0 12 36 - / Bit No.

When inserting the air flow adjustment dial, make sure that the D-shaped part of the rotary switch on the body fits into the D-shaped part of the dial mounting part. If the D-shaped part is inserted forcibly while it is not being fit into the appropriate part, the rotary switch or/and air flow adjustment dial may be broken. D-shaped part A Air flow adjustment dial D-shaped part 18 Doc.

Dry air, N2, Ar 0.2 to 10.5 L/min 1 0.5 to 26.3 L/min 1 to 52.5 L/min 2 to 105 L/min 2 Display flow range Instantaneous CO2 0.2 to 5.2 L/min 0.5 to 13.1 L/min 1 to 26.2 L/min 2 to 52 L/min flow Dry air, N2, Ar 0 to 10.5 L/min 1 0 to 26.3 L/min 0 to 52.5 L/min 0 to 105 L/min 2 Set flow range CO2 0 to 5.2 L/min 0 to 13.1 L/min 0 to 26.2 L/min 0 to 52 L/min Min. setting/display unit 0.01 L/