Cooling Capacity: 400 (38 kW), Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: Rc, Power Supply: 46 (50/60Hz: 3-phase 380 to 415 VAC; 60Hz: 3-phase 460 to 480 VAC), Option: Option Combination A+K
AL430/460 micro mist lubricators produce an oil fog that remains suspended in the air stream over longer piping distances. All types are available in North American, European metric, and standard metric configurations.
AL430/460 micro mist lubricators produce an oil fog that remains suspended in the air stream over longer piping distances. All types are available in North American, European metric, and standard metric configurations. Atomizes lubricant into fine particles at uniform rate; Drip rate easily monitored with sight dome; Standard bowl guard; High-response time; Damper precludes oil flooding
Cooling capacities: 9.5 kW, 14.5 kW, 20.5 kW (60Hz); Temperature range setting: 5 to 35°C; Temperature stability: ±0.1°C (10, 15 kW); ±1.0°C (20 kW); Power supply requirement: 3ph 380~415 VAC 50/60Hz, 3ph 460~480 VAC 60Hz; Waterproof specification: IPX4; Refrigerant: R410A (HFC); Circulating fluid: Tap or deionized water, or 15% ethylene glycol solution
Cooling capacities: 9kw (air cooled), 10.5kW (water cooled); Temperature range setting: 5 to 35°C; Temperature stability: ±0.5°C; Power supply requirements: 3-phase 200VAC; 50Hz; 200~230VAC 60Hz; 380~415VAC 50/60Hz; 460~480VAC 60Hz; Refrigerant: R410A HFC; Circulating fluid: tap or deionized water or 15% ethylene glycol solution
Cooling capacities: 9.5 kW, 15.5 or 20.5 kW; Temperature range setting: 5 to 35°C; Temperture stability: ±1.0°C (9.5, 14.5 kW); ±1.0°C (20.4 kW); Power supply requirement: 3ph 380~415 VAC 50/60 Hz; 3ph 460~480 VAC 60Hz; Waterproof specification: IPX4; Circulating fluid: tap or deionized water or 15% ethylene glycol solution
Cooling capacity: 10.5 kW, 15.7 kW, 20.5 kW, 25 kW; Power supply: 380-415VAC (50/60 Hz) or 460-480VAC (60 Hz), 3-phase (460VAC excludes 10.5 kW); Temperature range setting: 5 to 35° C; Temperature stability: ±0.1° C; Outstanding energy saving effect with the triple inverter. Power consumption reduced by 53 %; Compact, Space-saving
Cooling capacities: 11.5 kW, 15.7 kW, 20.6 kW, 24 kW; Power supply: 380-415VAC (50/60 Hz) or 460-480VAC (60 Hz), 3-phase (460VAC excludes 11.5 kW); Temperature range setting: 5 to 35°C; Temperature stability: ±0.1°C; Outstanding energy saving effect with the triple inverter. Power comsumption reduced by 53%; Compact, Space-saving
Cooling capacity: CH1= 9, 19 or 26kW (oscillator); CH2= 1kW (optical system); Power Supply "20": 200VAC/50 Hz or 200-230VAC/60 Hz, 3-phase; Power Supply "40": 380-415VAC (50/60 Hz) or 460-480VAC (60 Hz), 3-phase; Temperature set range: CH1 = 15 to 25°C, CH2 = 20 to 40°C; Temperature stability: CH1 = ±0.1°C, CH2 = ±0.5°C; Refrigerant: R410A; Communication: contact/analog I/O; Serial RS-232C
Total cooling capacity: 9.5kW (air)/11.0kW (water) (CH1 oscillator, CH2 optical system combined); Power supply "20": 200VAC/50 Hz or 200-230VAC/60 Hz, 3-phase; Power supply "40"; 380-415VAC (50/60 Hz) or 460-480VAC (60 Hz), 3-phase; Temperature set range: CH1 = 15 to 25°C, CH2 = 0 to 15°C; Temperature stability: CH1 = ±0.1°C, CH2 = ±0.5°C; Refrigerant: R410A; Communication: contact/analog
Cooling capacities: 9.5 kW, 14.5 kW, 20.5 kW, 38 kW; Temperature range setting: 5 to 35°C; Temperature stability: ±0.1°C (10, 15, 38 kW); ±0.1°C (20 kW); Power supply requirement: 3ph 380~415 VAC 50/60Hz, 3ph 460~480 VAC 60Hz; Waterproof specification: IPX4; Refrigerant: R410A (HFC); Circulating fluid: Tap or deionized water, or 15% ethylene glycol solution
Fluid fill, drain port, and filter access on the front; Color LCD screen with control pad for settings and diagnostics; RS-232C / RS-485 Communication functions; Cooling/Heating capacity (W): 5900/1200; Temperature stability: ±0.1°C; Power supply requirement: 380-415VAC, 50/60Hz, or 460~480Vac, 60Hz; Circulating Fluid: water or 15% ethylene glycol; Standards: CE, RoHS
Fluid fill, drain port, and filter access on the front; Color LCD screen with control pad for settings and diagnostics; RS-232C / RS-485 Communication functions; Cooling/Heating capacity (W): 5900/1200; Temperature stability: ±0.1°C; Power supply requirement: 380-415VAC, 50/60Hz, or 460~480Vac, 60Hz; Circulating Fluid: water or 15% ethylene glycol; Standards: CE, RoHS
The ITV series is IP65 equivalent.Controls air pressure in proportion to an electric signal, Pressure range of -1.3 to -80kPa, Available port size 1/4, Mounting bracket option REGULATOR, ELECTROPNEUMATIC. 2000 Size Electro-Pneumatic Regulator. 460 lb.
Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 460, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: No, Valves: Presence, Cushion: None, Operating Pressure(MPa): 0.1 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 460, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Non-use of Copper and fluoropolymer-based Material (Partially Plating), End Locking: [Included] Presence, Valves: -, Cushion: Air cushion, Operating Pressure(
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 460, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 460, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: High speed / high frequency, End Locking: No, Valves: No, Operating Pressure(MPa): 0.05~1.0, Port thread type: Rc, Auto Switches: Without auto switch (built-in
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 460, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: High speed / high frequency, End Locking: No, Valves: No, Operating Pressure(MPa): 0.05~1.0, Port thread type: Rc, Auto Switches: C73, Lead Wire Length(m): 3
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 460, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: No, Valves: No, Operating Pressure(MPa): 0.2~1.0, Port thread type: Rc, Auto Switches: Without auto switch (built-in magnet), Lead Wire